  1. I'll let Andy the minion have look first...

    I'll let Andy the minion have look first remotely.. Then try that, as pretty sure not seen this before, and seen it 3 times in a day now. Plus I log my temps and SP, so would of seen this. I have...
  2. Ok thats the third time my dining room has set...

    Ok thats the third time my dining room has set the SP to 30'C, it is only doing in my dining room that I have noticed. It is only when optimising start is working, once the room is at its time...
  3. Its not 10 degrees temp, it is 10Degree below...

    Its not 10 degrees temp, it is 10Degree below setpoint so if your setpoint is 16'C and above, and your difference in outside temperature is 10'C then your room will boost if set.

    I agree the...
  4. Set Point Issue on one room. Seen this twice...

    Set Point Issue on one room.

    Seen this twice now, my dining room keeps getting a Setpoint 30íC, this happen yesterday after software update and this morning while dining room was pre heating...
  5. Cold boost working I think, see pics. got mine...

    Cold boost working I think, see pics. got mine set to 0.5'C boost and it has change schedule setpoint up by 0.5C and placed the boost symbol on screen. Rooms selected for boost did not boost if SP...
  6. My software has changed. Great. Looking...

    My software has changed. Great.

    Looking forward to seeing if over shoots can be settled down, might save me having to change a couple of older valves out.

    Warm weather shutdown would be good, ...
  7. Applied, hopefully get it...

    Applied, hopefully get it...
  8. Replies
    73
    Views
    18,494

    I thinks its good, see the projects have...

    I thinks its good, see the projects have reduced to three. That will allow 18 sensors to be logged so setpoint & actual of 9 zones of evohome. Perfect for me, 9 rads

    I have it setup to log to...
  9. I would use Y87RF in the room that you desire...

    I would use Y87RF in the room that you desire most comfort, maybe living room, or if you have any radiators in rooms you use alot that the hr92 could have free air movement blocked due to radiator...
  10. https://getconnected.honeywellhome.com/en/sites/ge...

    https://getconnected.honeywellhome.com/en/sites/getconnected.honeywell.com.en/files/evohome%20Installation%20Guide%20-%20gateway%20model.pdf

    page 14 and 17 should allow you to install all...
  11. Replies
    2
    Views
    302

    Poll: If I did not have the honeywell electronic TRVs...

    If I did not have the honeywell electronic TRVs and just wanted a House single thermostat and boiler control I would not use Evohome. I think the Nest/Hive look better and have better functionality....
  12. Replies
    40
    Views
    4,657

    When is Heating Season Q3......?

    When is Heating Season Q3......?
  13. Had a play about with balancing radiators. Got...

    Had a play about with balancing radiators. Got all of them with about a 10'C drop across valves with boiler running 61'C.

    Then left system couple of days. Found a couple of rooms could not keep...
  14. Replies
    385
    Views
    38,847

    APP is down, system working. Yeah my graphs...

    APP is down, system working.

    Yeah my graphs are returning the same data as 1 am this morning.. so they look great and steady :)

    IFTTT did not work yesterday on geofencing either..
  15. Understand your point. Its all good and...

    Understand your point. Its all good and interesting and gives me something tinker with. Work with proportional control at work, big industrial shit. For me it just needs a small change, a variable...
  16. DBMandrake Another great response and had a...

    DBMandrake
    Another great response and had a play with Valencia after reading your other thread.

    Ok, correction to my statement my Valencia is opening some where above 17%(close) and definitely...
  17. Checked the honeywell valencia trv and valve was...

    Checked the honeywell valencia trv and valve was 13% position and definetly passing water across it.

    Set valve stroke to Full 1 and disconnected TRV and Reconnected to calibrate again.

    So...
  18. Hi DBMandrake, Thanks for the awesome reply. ...

    Hi DBMandrake,
    Thanks for the awesome reply.

    Yeah I trust what your saying, and just describing what I am seeing to try to help a bit.

    Yes sometimes the TRVs stay closed when another is...
  19. Hi Sombody, Yeah I hope they know...

    Hi Sombody,
    Yeah I hope they know that and followed the instruction, if you read through from top this is a problem with the mechanical TRV Valve is passing due to adaptor( the one...
  20. OK - sounds good - two links for honeywell trvs...

    OK - sounds good - two links for honeywell trvs bodies, sometimes just as cheap to buy body and plastic head.

    https://theevohomeshop.co.uk/14-radiator-valves...
  21. Yeah Standard/most common(supplied with Hr92) is...

    Yeah Standard/most common(supplied with Hr92) is the M30. So if pins are not touching then, you must have a different type, if hes managed to screw it on it must be m30. Unless hes cross threaded...
  22. Hi, please forgive the simple question, but...

    Hi,
    please forgive the simple question, but have you fitted the adator to your mechanical TRV?


    1493


    I assume you have.

    Remove HR92 , manually turn adaptor wheel closewise to close the...
  23. Hi, what seems to be general opinion, which...

    Hi,
    what seems to be general opinion, which I have read and noticed by monitoring the data that I log on the system. The Valves will operate/stay open up to Set point plus 1.5'C, so whether...
  24. Replies
    2
    Views
    348

    If its going from closed to open theres less...

    If its going from closed to open theres less load, sticky valve would not cause this extra time opening, stronger spring would push up so assist motor. You say two years old, Have you tried new...
  25. Replies
    1
    Views
    283

    Obviously you can use the dashboard, but the...

    Obviously you can use the dashboard, but the project seems to log at a high sample rate. Plus the Dashboard you can only get 12 items on it. See below.

    1470


    You can see the Google Sheet...