Search:

Type: Posts; User: mylesm

Page 1 of 7 1 2 3 4

Search: Search took 0.00 seconds.

  1. Replies
    60
    Views
    3,211

    In my case I have a bypass rad in the bathroom...

    In my case I have a bypass rad in the bathroom but in the summer with no heat on when the HW Zone valve opened and boiler fired the bypass rad was also getting hot and overheating the bathroom

    I...
  2. Replies
    4
    Views
    290

    Thanks its showing full 3 bars I am using...

    Thanks its showing full 3 bars I am using Alkalines and set it correctly but like clockwork its there again this am at 05:53 its the fact it always logs at the same time I find unusual
  3. Replies
    4
    Views
    290

    Hr92 Low Battery

    Hello

    I have a HR92 on a Bathroom Rad the Room is not used at the moment and the Temp setpt is set to 13c permanent room never gets below 19 anyway Airing Cupboard is in the same room

    Every...
  4. Putting the relay after the controller will be...

    Putting the relay after the controller will be better in your case as I think the controller will not power up in an on state as you need if you put it before controller then everytime the BDR or...
  5. HI I have electric underfloor heating in two...

    HI

    I have electric underfloor heating in two bathrooms and they operate as 2 Evohome Electric Zones

    Problem with the controller you mention is if you power it off ie put relay before...
  6. Replies
    5
    Views
    780

    I have had a DTS92E in my bathroom for the last...

    I have had a DTS92E in my bathroom for the last couple of years without issue
  7. Replies
    1
    Views
    636

    I use Evohome and I have a mix of radiator Zones...

    I use Evohome and I have a mix of radiator Zones and underfloor Electric heating Zones These are all controllable from one app etc also Electric Zones do not call Boiler as they do not need to I do...
  8. Replies
    7
    Views
    2,031

    I have intergas rapid boiler with opentherm...

    I have intergas rapid boiler with opentherm bridge and Evohome with HR92 actuators on all Rads except one for Bypass I use DTS92 Wall Mounted Temp Sensors for Zone Temp measurement and I find it...
  9. Replies
    7
    Views
    1,327

    I also have no Outside Temp displayed on my...

    I also have no Outside Temp displayed on my Controller Display I have Firmware with Electric Zone control My app shows weather info for my location but no display on controller I posted about this...
  10. Replies
    7
    Views
    1,623

    I have done this With an Electric Heater in A...

    I have done this With an Electric Heater in A Bedroom HC60NG and a Round Stat as Temp Sensor all Done through Evohome Electric Zone, Works Perfect Using Evo means I can schedule Zone or Switch it on...
  11. Replies
    5
    Views
    2,146

    I installed HW Kit Last weekend and as you said a...

    I installed HW Kit Last weekend and as you said a simple matter of adding it Under System Devices by Enabling Stored Hot Water and then wired BDR to MV and all is good
  12. Replies
    5
    Views
    2,146

    Great thats what I was hoping so will install...

    Great thats what I was hoping so will install this weekend
  13. Replies
    5
    Views
    2,146

    Thanks for that my Boiler is already in service...

    Thanks for that my Boiler is already in service as a heat only and I now want to add Stored HW so I will just try to add it and see how I go
  14. Replies
    5
    Views
    2,146

    Opentherm Boiler control Add Hot water

    I have an intergas boiler heat only with opentherm boiler control

    I now want to add Stored Hot Water I have the Hot Water Kit is it jus a matter of adding it under system devices I have a new MV...
  15. Replies
    3
    Views
    1,210

    Dts92 is still working fine and reflecting in...

    Dts92 is still working fine and reflecting in Evohome
  16. Replies
    3
    Views
    1,210

    After looking at Zone Config on Evohome I added...

    After looking at Zone Config on Evohome I added extra actuator and it showed 3 devices bound and new HR92 is showing Correct Zone name in its Display so I presume it will now work in conjunction with...
  17. Replies
    3
    Views
    1,210

    Add Extra Hr92 to Existing Zone

    Hi All

    I have a Zone which has 2 Rads with 2 HR92 Actuators and a DTS92 as Temp Sensor working fine I now want to add an extra HR92 to this Zone is there an easy way to do this or do I have to...
  18. If I understand you Correctly I have Done this by...

    If I understand you Correctly I have Done this by setting up a Zone as a Zone Valve and then Bind a Spare BDR to it as Zone Valve Actuator and T87RF as Stat and just dont wire a valve to BDR just use...
  19. When you say the Valve is Making Rotating Sound...

    When you say the Valve is Making Rotating Sound but not actually rotating how do you determine the Valve is not rotating

    Sounds like may be sticky TRV Body you could swap over the HR92 Head to a...
  20. Replies
    43
    Views
    7,466

    [QUOTE=nigethechap;36712]We have a wood burning...

    [QUOTE=nigethechap;36712]We have a wood burning stove in the lounge. I'm just worried i'm over using the heating.
    What do you guys think to this schedule ?

    Oh well that's totally different I...
  21. Replies
    43
    Views
    7,466

    So the Warmest you have your Lounge is 17c I have...

    So the Warmest you have your Lounge is 17c I have mine at 21c I would find 17c very cool
  22. Yes I think the DTS can be offset Even in EVO I...

    Yes I think the DTS can be offset Even in EVO I did it before when setting up some but its a while ago so worth Checking
  23. NO Hold On DTS92E definitely has a hidden menu...

    NO Hold On DTS92E definitely has a hidden menu where you can set an offset so it may be possible with Y87RF

    https://www.manualslib.com/manual/815171/Honeywell-Y9420h.html?page=13

    Worst Case...
  24. Replies
    125
    Views
    30,518

    I would say None whatsoever I agree that most...

    I would say None whatsoever

    I agree that most of your savings were down to the New Boiler Like a lot of things we get into Diminishing returns here the majority of savings come early as we upgrade...
  25. Replies
    125
    Views
    30,518

    This is First Winter with Intergas Boiler I had a...

    This is First Winter with Intergas Boiler I had a worcester was about 10 years old so changed it for Intergas As you are probably Aware Intergas Boilers can be setup as Combi,System,Open Vent,simply...
Results 1 to 25 of 158