Search:

Type: Posts; User: DBMandrake

Page 1 of 20 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    72
    Views
    3,245

    I've set my Away to 10 degrees as well. Heating...

    I've set my Away to 10 degrees as well. Heating Off and Away have different use scenarios.

    Heating Off is for summer when you just want to completely turn off the heating schedule but still allow...
  2. Replies
    72
    Views
    3,245

    Touch wood I have had no comms errors since...

    Touch wood I have had no comms errors since rotating it. (Whereas Lithium batteries alone didn't cure it)

    Whether the polarisation helps may depend on the orientation of the CS92A relative to...
  3. I bought a NanoCUL with 868Mhz CC1101 already...

    I bought a NanoCUL with 868Mhz CC1101 already assembled:

    https://www.ebay.co.uk/itm/nanoCUL-USB-Stick-FTDI-CC1101-868MHz-FW-1-67-Knick-Antenne-FHEM-CUL-868-Adapter/372221622516

    It took several...
  4. Replies
    3
    Views
    211

    I've only recently added a second HR92 to a zone...

    I've only recently added a second HR92 to a zone so I'll have to try this out to see if I notice a problem with Disable Local Override..

    Regarding the window open detection - you can also disable...
  5. Replies
    72
    Views
    3,245

    Not while it is scheduled off, no. It typically...

    Not while it is scheduled off, no. It typically drops from 54C down to about 42C when scheduled off overnight, and down to about 46C when scheduled off during a work day.

    Of course if I run a bath...
  6. I think most of us here have... It's the...

    I think most of us here have...

    It's the Honeywel connected specalists who apparently have not... :D
  7. Honeywell wireless thermostat for electric heater

    Just a question on behalf of a colleague....

    Does Honeywell do a standalone single zone wireless thermostat which is designed for an electric radiator and has a built in weekly schedule ?
    ...
  8. Replies
    1
    Views
    165

    You've left your overall system configuration a...

    You've left your overall system configuration a bit vague - more info about the overall system setup would be helpful.

    It sounds like the zone in question is the electric heating panel ? So...
  9. When you do the RF test it always makes the light...

    When you do the RF test it always makes the light on all BDR91's flash together no matter whether you "test" the heating or hot water relays. It's just a quirk - our systems all do that too. So you...
  10. Replies
    15
    Views
    843

    I'm no expert but I would have thought that hot...

    I'm no expert but I would have thought that hot water priority is only useful if you have a "quick heat" cylinder which has a proper plate heat exchanger in it, so that the heat to the radiators is...
  11. Replies
    72
    Views
    3,245

    Yep, I have.

    Yep, I have.
  12. Replies
    15
    Views
    843

    If your system has a heating zone valve you could...

    If your system has a heating zone valve you could wire in hot water priority fairly easily.

    Do you have both heating and hot water zone valves and two BDR91's controlling them ? If so just take...
  13. Replies
    72
    Views
    3,245

    It's certainly something I'm willing to try at...

    It's certainly something I'm willing to try at some point further down the line, and would certainly rule out or implicate the battery connections depending on the result.

    But first I'd like to...
  14. Replies
    72
    Views
    3,245

    You must have missed the posts where I said I...

    You must have missed the posts where I said I swapped in brand new Energizer Lithium Ultimate a couple of days ago... :)

    If anything it made things worse, although I suspect the physical...
  15. Replies
    72
    Views
    3,245

    And another 3+ hour outage of the hot water...

    And another 3+ hour outage of the hot water sensor tonight resulting in an error on the screen and no hot water reheat. Take the battery out and put it back in - instant temperature reading. Getting...
  16. Replies
    72
    Views
    3,245

    I've never had a low battery alert from my CS92A...

    I've never had a low battery alert from my CS92A because I always start having a lot of problems with the sensor long before the batteries get low enough to trigger a low battery alert. I don't even...
  17. Personally I don't think Evohome is to blame...

    Personally I don't think Evohome is to blame here, even though the documentation could be better.

    It's the whole heating engineer trade which a few present company here excepted, just don't seem...
  18. Replies
    72
    Views
    3,245

    Yes I use the strap on sensor on a vented...

    Yes I use the strap on sensor on a vented cylinder. If it was faulty it means both have been faulty as the sensor was also replaced when the first CS92A was replaced under warranty so I think that's...
  19. Replies
    72
    Views
    3,245

    The default hot water overrun is 0 minutes and...

    The default hot water overrun is 0 minutes and differential is 10, it's just the set point I couldn't remember.
  20. Replies
    72
    Views
    3,245

    Yeah I've tried it on a stand closer to the...

    Yeah I've tried it on a stand closer to the boiler closet. It's not a signal strength or interference issue. No other devices on the system are affected including those in the same closet.
  21. Replies
    72
    Views
    3,245

    Just thought of something. 1) Does anyone...

    Just thought of something.

    1) Does anyone remember for certain what the default hot water set point and differential is in the Evotouch on a factory reset controller when you first add hot water...
  22. Replies
    72
    Views
    3,245

    Well that didn't last long. Before I went to bed...

    Well that didn't last long. Before I went to bed last night I was greeted with a big red "comms fault hot water sensor". :mad:

    I went to press the test button on the CS92 and it merrily flashed 5...
  23. Replies
    72
    Views
    3,245

    Now you tell us... ;) What prompted you to try...

    Now you tell us... ;)

    What prompted you to try Lithium in the CS92A when the installation manual says Alkaline only ? I'm doing it against the recommendation in the manual specifically due to us...
  24. Replies
    72
    Views
    3,245

    Let us know how that goes. Hopefully 3.3 volts...

    Let us know how that goes. Hopefully 3.3 volts (1.65 per cell) is sufficient to avoid unnecessary power saving measures in the device as that's basically exactly the new voltage of a standard...
  25. Replies
    72
    Views
    3,245

    Did you ever try using Lithium AA batteries in...

    Did you ever try using Lithium AA batteries in the CS92A ? After meaning to do it for over a year now I finally gave in and ordered some Energizer Ultimate Lithium AA cells for mine and fitted them...
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4