  1. domoticz dashboard temperature graphs?

    Hi all, I've just got domoticz installed here, first time I've played with it, just using the Evohome web API for now and it's already pulling in my temperature readings, I was just wondering if...
  2. I have my DHW set to 55 degrees, and the schedule...

    I have my DHW set to 55 degrees, and the schedule gives it a blast early in the morning for my shower and then late afternoon so the wife can do some washing when she gets back from work then a final...
  3. Ah I should have said, I'm on y-plan here so need...

    Ah I should have said, I'm on y-plan here so need minimum 65 degrees really to heat the hot water cylinder. Even to get that temp I have to have the dial on about 5.75. If I run it on 4, or wherever...
  4. Yes mine is also 26kw it's the WB1B variant, open...

    Yes mine is also 26kw it's the WB1B variant, open vent heat only boiler, if you have the same, what position is your temperature dial? I have to turn mine to half way between position 6 and "reset"...
  5. Replies
    5
    Views
    4,863

    That sounds very odd, if all the RF devices are...

    That sounds very odd, if all the RF devices are suddenly having a problem then it sounds more likely a problem with the evotouch panel/controller thing rather than the individual BDRs. Have tried...
  6. Boiler can't modulate down low enough

    Hi, just an observation, I've noticed that when I'm sat in my home office with just the office radiator on (evohome shuts down the rest of the house during the day) my boiler can't seem to modulate...
  7. It sounds like the radiator might be a bit...

    It sounds like the radiator might be a bit oversized for the room, maybe something you can try is to reduce it's output by adjusting the lockshield valve, but I'm not sure the best way to adjust it....
  8. Lots of installers seem to hang out here: ...

    Lots of installers seem to hang out here:

    https://www.plumbersforums.net/forums/central-heating-forum.21/
  9. Replies
    1
    Views
    356

    Does what it says on the tin

    I work from home, now the weather has turned I'm nice and toasty in my home office and not burning loads of gas heating the rest of the house...

    1870

    1871
  10. Replies
    13
    Views
    3,573

    Interesting. I agree that it is lacking a bit in...

    Interesting. I agree that it is lacking a bit in certain areas, the app leaves a lot to be desired and it would be great if it produced some decent reports of ambient temperature vs set point vs...
  11. Yep that's what I did. I just installed a wall...

    Yep that's what I did. I just installed a wall mounted back box and blanking plate in the airing cupboard to house the transformer.
  12. I replaced my wall mounted room stat with the...

    I replaced my wall mounted room stat with the Evotouch panel and used the old thermostat wiring to provide the DC for the panel (using the wall mount kit). The wiring should go to your wiring centre,...
  13. Replies
    6
    Views
    968

    I've got to be honest I didn't really understand...

    I've got to be honest I didn't really understand all that, it seems like there's some biasing and averaging going on, but I don't really understand why the wall display can't just display what the...
  14. Replies
    6
    Views
    968

    Temperature discrepancy

    So why does this happen?

    1860

    1861
  15. Replies
    7
    Views
    799

    Just a radiator.

    Just a radiator.
  16. I'm just double-checking, the initial...

    I'm just double-checking, the initial acknowledgement comes from a noreply address, but when a human responds it comes from a real address, I also seem to have some from consumersupportuk@resideo.com...
  17. Hmm that's weird because I have had email...

    Hmm that's weird because I have had email dialogue with them after raising a ticket, the emails come from consumersupport@honeywellhome.com and the ticket number is in the subject line, so if you...
  18. I've raised a few tickets now... ...

    I've raised a few tickets now...

    https://ensupport.getconnected.honeywellhome.com/s/contactsupport?language=en_US
  19. Replies
    7
    Views
    799

    How are you getting on, do you have heat yet? ...

    How are you getting on, do you have heat yet?

    I am getting more and more instances of the boiler doing short cycling now, it happens where there is very low demand (typically less than 10%) and...
  20. You have an identical setup to me, and yes what...

    You have an identical setup to me, and yes what you describe is normal.
  21. Probably easier to chuck them on ebay tbh,...

    Probably easier to chuck them on ebay tbh, they'll deffo sell on there at that price.
  22. Replies
    9
    Views
    958

    I'm finding references to pre- and post-2008...

    I'm finding references to pre- and post-2008 regs, but struggling to find specific info about the pre-2008 regs, will keep digging.
  23. Replies
    9
    Views
    958

    Oh that's interesting, conservatory was built...

    Oh that's interesting, conservatory was built some 15+ years ago, any idea when those regs came in?
  24. Replies
    9
    Views
    958

    When we had the conservatory built they did give...

    When we had the conservatory built they did give us the option of installing UFH but I was nervous about the cost of leccy to power it so didn't bother in favour of two stonking great radiators - the...
  25. Replies
    9
    Views
    958

    Winter's coming!

    Evohome doing a nice job at the moment, I guess the percentages will start to creep up as the evenings get cooler...