    Same here, if it's set to OFF it ignores the...

    Same here, if it's set to OFF it ignores the schedule. Our spare room got set to OFF accidentally one day and it was several days later that I realised it was never heating despite the schedule. The...
  2. Replies
    20
    Views
    343

    Frost protection is disabled in OFF mode. I've...

    Frost protection is disabled in OFF mode. I've tested this before more than once with an HR92 screwed onto a spare valve body thrown into the freezer. Honest.

    Are you sure that your valve body...
  3. Replies
    20
    Views
    343

    I've tested OFF on HR92's many times and OFF...

    I've tested OFF on HR92's many times and OFF means OFF.

    It will completely ignore the schedule and remote manual overrides, furthermore OFF disables frost protection. (I tested this placing one in...
  4. I'm not saying it doesn't save money, just that...

    I'm not saying it doesn't save money, just that that is not the reason for me to use the feature, I enable it for smoother temperature control without overshoots. I don't have any data one way or the...
  5. Long press on settings -> Zone configuration ->...

    Long press on settings -> Zone configuration -> choose your zone for the DTS92E -> Temperature sensor -> Remote sensor, then follow the instructions to complete the binding.

    The binding button...
  6. I use it mainly to avoid temperature overshoots...

    I use it mainly to avoid temperature overshoots caused by scheduled set point changes in warmer weather.

    This it does well. I don't expect it to save me any money.
  7. Opposite way around for me. Normal results in...

    Opposite way around for me. Normal results in cold rooms and radiators reluctant to actually heat up, partial works very well for me, I've been using it for months now.
  8. Replies
    6
    Views
    291

    I can confirm that this charging bug still exists...

    I can confirm that this charging bug still exists in the 19.33 firmware. I fitted brand new rechargeable batteries several months ago and ensured they were fully charged, when I recently removed the...
  9. Replies
    5
    Views
    299

    Nope, no difference. I've used both types -...

    Nope, no difference.

    I've used both types - usually the one with just the thermostat but in one case I bought the pack which includes the relay as I wanted another relay to add a boiler relay and...
  10. Replies
    11
    Views
    693

    All mine bought from 5 years ago up until one...

    All mine bought from 5 years ago up until one replacement last year have firmware 1.01 as reported when the batteries are inserted.
  11. Replies
    31
    Views
    3,232

    As of yesterday my old loop monitor is still...

    As of yesterday my old loop monitor is still working on the phone app - I've been too busy to install the new one yet and also haven't migrated my account. Sounds like that might have been a good...
  12. All I see in that article is that Ikea plan to...

    All I see in that article is that Ikea plan to stop selling virtually all non-rechargeable batteries (not just Alkaline) over "environmental concerns".

    So just buy from somewhere other than...
  13. Why are IKEA stopping sale of Alkaline batteries...

    Why are IKEA stopping sale of Alkaline batteries and why do you think everyone else will follow?

    First I've heard of sales of Alkaline batteries stopping anywhere.

    Despite the NiMH setting,...
  14. According to this link ProCell are the same as...

    According to this link ProCell are the same as Duracell industrial:

    https://www.batterystation.co.uk/brands/duracell-batteries/industrial-by-duracell-formerly-procell.html

    I've just been using...
  15. To do it properly it has to be unbound at both...

    To do it properly it has to be unbound at both the HR92 end and the controller end before binding it to the new zone or odd things can happen....

    The first part is easy - press the button on the...
  16. Replies
    4
    Views
    357

    Yes, I have had low battery alerts from DTS92E's...

    Yes, I have had low battery alerts from DTS92E's and then had to change batteries.

    From the traffic I've monitored it doesn't seem to send regular battery status messages nor does it send a...
  17. Wow, I really don't like the sound of that. There...

    Wow, I really don't like the sound of that. There must be a way to bypass the original wireless thermostat in the future...you don't want to be relying on it especially if it is battery powered.
    ...
  18. Replies
    4
    Views
    321

    If you check the picture in post #10 in the...

    If you check the picture in post #10 in the following thread, the far left and far right valves are the Valencia's I fitted, with the balancing insert screwed in different amounts to illustrate the...
  19. Replies
    4
    Views
    321

    The Valencia have a plastic balancing insert...

    The Valencia have a plastic balancing insert which screws down around the pin - although I was pretty sure on mine it's black plastic not white... in any case, this plastic piece can screw down or be...
  20. The HR92 can measure lower than freezing (I've...

    The HR92 can measure lower than freezing (I've tried it when testing frost protect mode) however doing so you will trigger frost protect mode and likely cause the boiler to come on even if it's not...
  21. Would you agree that an automatic bypass valve is...

    Would you agree that an automatic bypass valve is still required though ? I assume you have one ?

    If the system was originally installed with a bypass radiator and no automatic bypass valve and...
  22. Item one is almost certainly an automatic bypass...

    Item one is almost certainly an automatic bypass valve.

    This is a spring loaded one way valve which will remain fully closed until a pre-set pressure differential is reached before it begins to...
  23. Indeed, it sounds like there is no automatic...

    Indeed, it sounds like there is no automatic bypass valve as if there was one then only one or two radiators opening slightly would cause most of the flow to go through the ABV causing a very low...
  24. No answers at the moment but I have some...

    No answers at the moment but I have some questions:

    1) What is delta max set to on the boiler ?
    2) Is the pump an automatic (load sensing) variable speed pump or a fixed speed pump, if the latter...
  25. Replies
    11
    Views
    969

    Thanks for independently confirming that there is...

    Thanks for independently confirming that there is indeed a stroke compatibility issue with the HR91 with some valve bodies. As I mentioned in an earlier post I even had an issue with the HR91 not...