  1. So what you are saying basically is that the best...

    So what you are saying basically is that the best thing is to install a boiler that has the lowest kw rating,for example a. Viessmann that can modulate down to 3.2 kw from say 24kw max.
  2. Totally agree,think what youíve said sums it up...

    Totally agree,think what youíve said sums it up perfectly.Regardless of boiler output the boiler can do nothing but cycle once the target temperature has been met with Evohome.
  3. Think your absolutely right and unfortunately...

    Think your absolutely right and unfortunately with my boiler being too big and poor modulation turndown,that is the result,cycling.Now I am armed with much more knowledge,when I’m due a replacement I...
  4. Yes it seems to be and maintaining a lower return...

    Yes it seems to be and maintaining a lower return temp until the heating demand is satisfied.
  5. Just a bit of an update to my last post,I've just...

    Just a bit of an update to my last post,I've just had my boiler serviced and checked,the engineer couldn't find any problems with the boiler but I'd ordered two new Ntc's,one for flow and one for...
  6. Replies
    3
    Views
    526

    Once it’s linked to Evohome it doesn’t show the...

    Once it’s linked to Evohome it doesn’t show the flame icon,just shows the Wi-Fi symbol,perfectly normal and nothing to worry about,have one in my kitchen which does the temp sensing for a Hr92 on my...
  7. Well it seems I’ve had a bit of a...

    Well it seems I’ve had a bit of a breakthrough,over the weekend I’ve spent time carefully re-balancing the radiators and altering the range rating on my boiler and tweeking the flow temperature,it...
  8. Yes it totally understand what you are saying and...

    Yes it totally understand what you are saying and that's probably right,unfortunately the boiler doesn't modulate to a low output,the flow temp does go down but only after it's shut down and goes...
  9. The temp increases when the boilers running,still...

    The temp increases when the boilers running,still demanding heat to satisfy what the Hr92 are asking for but instead of it staying at what’s been set at the boiler it continues to heat up between 5-8...
  10. Yes I think I will get a temperature sensor,would...

    Yes I think I will get a temperature sensor,would an infrared one be ok?Phoned the vaillant repair company near me yesterday regarding my problem and after giving him lots of info and telling him...
  11. Going to get one booked and see what’s going on...

    Going to get one booked and see what’s going on and the boilers about due it’s annual service/check.Found someone not far from me that knows a lot about Vaillant boilers so I’ll keep the thread...
  12. Thanks Bruce,yes that's what I've done as a work...

    Thanks Bruce,yes that's what I've done as a work around but it still goes over by the same amount but at least it doesn't go sky high and bring the return way above where it needs to be.
  13. Hi Bruce,no I haven’t unfortunately.D5 on the...

    Hi Bruce,no I haven’t unfortunately.D5 on the boiler reads 70 which is what I have it set at,D40 is where I can see it’s going over it’s set temp and eventually the return rises up to meet the flow...
  14. Vaillant 831 Ecotec Plus going over set temp

    Noticed a strange thing with my boiler over the last couple of days,the set temp is 65 degrees but when I've checked d40 it's going between 5-8 degrees over the set temp.My boiler is the Vaillant 831...
  15. Replies
    10
    Views
    682

    I have an Evohome system and all my radiators...

    I have an Evohome system and all my radiators have Hr92’s on them including my bathroom towel rad and smiths plinth heater.I phoned the Evohome shop and spoke to Richard,the owner who advised me on...
  16. Replies
    5
    Views
    833

    We live in a 1926 semi detached house and not...

    We live in a 1926 semi detached house and not long after we moved in we started having major problems with condensation on not only our windows,but on some of the internal walls but only upstairs. I...
  17. Replies
    11
    Views
    879

    Yes it’s been acting up for me too,most of the...

    Yes it’s been acting up for me too,most of the day.Seems to be ok now.
  18. The thing is with Evohome is that it works,I’m...

    The thing is with Evohome is that it works,I’m not really bothered about how the app looks or anything else because it does what it’s supposed to.My system is running opentherm and again it works...
  19. +1 for the fully assembled unit please.Kind...

    +1 for the fully assembled unit please.Kind regards Gary.
  20. That’s great,will do.At the moment it seems what...

    That’s great,will do.At the moment it seems what I have done so far has sorted the problem.Thanks for all your help,it’s much appreciated.
  21. Heating set point is 5 degrees on the Hr92,just...

    Heating set point is 5 degrees on the Hr92,just checked.Wound the balancing insert out so it’s loose then turned back in.Tightened the plastic Hr 92 body onto the valve making sure the black wheel is...
  22. Forgot to say,on the evotouch it's showing the...

    Forgot to say,on the evotouch it's showing the kitchen set back to 5 degrees which is what all zones are set to when off.This is also the same with the round thermostat,its showing 5 degrees too.Must...
  23. Zone activating when another zone is switched on

    Bit of a problem Iíve noticed today.Switched evohome on to run lounge radiator and towel rail in my bathroom,controlled by Hr92,no other zones on,or so I thought.Now the problem,Smiths plinth heater...
  24. Page one of this thread lists the new...

    Page one of this thread lists the new features,you should have received an email that contains the info you require.Lots of info contained within this tread,just need to read through the 68 pages.:D
  25. Mine seems to be behaving at the moment,17...

    Mine seems to be behaving at the moment,17 degrees on the Evotouch and the same being reported by Accu weather.