    I have a Zehnder ComfoAir/Cool Q600 and Evohome....

    I have a Zehnder ComfoAir/Cool Q600 and Evohome. They work independently.

    It keeps CO2 levels down and boosts automatically if higher humidity is detected for instance when showering.
    ...
  2. Replies
    22
    Views
    1,439

    > If I then go and turn up the temperature in a...

    > If I then go and turn up the temperature in a room that has not been used the boiler goes back up to 70c for a time because of the sudden influx of colder water from the radiator in that room
    ...
  3. Replies
    22
    Views
    1,439

    Sounds similar to...

    Sounds similar to this:https://www.diynot.com/diy/threads/flow-temperature-on-greenstar-junior.425160/
  4. Replies
    5
    Views
    707

    I had IFTTT problems yesterday/today as well. I...

    I had IFTTT problems yesterday/today as well. I wasn’t able to reconnect the service until later this afternoon
  5. You will need 2 BDR91s, 1 for your 2-port valves...

    You will need 2 BDR91s, 1 for your 2-port valves and the other for your Intergas DHW NTC.

    On a DHW demand, 1 BDR91 opens the DHW valve and closes the CH valve.

    The other BDR91 (also bound...
  6. It looks like the HCE80 works fairly autonomously...

    It looks like the HCE80 works fairly autonomously apparently calculating and responding to zone demands itself.

    For instance you will see it opening actuators for zones even when the Evotouch...
  7. I would clear all binding on the DHW BDR91, and...

    I would clear all binding on the DHW BDR91, and bind it again. It may be double bound.

    Press and hold the button for 15 seconds (until the red LED blinks rapidly) to clear any previous binding...
  8. Simply change Appliance Control to OpenTherm, you...

    Simply change Appliance Control to OpenTherm, you definitely don’t need to touch your HR92s and probably don’t need to touch your stored hot water CS92/BDR91 setup either, but simple to do if needed...
  9. 1. Yes 2. CS92 sensor and high-limit thermostat...

    1. Yes
    2. CS92 sensor and high-limit thermostat controlling DHW valve
    3. NO 2-port that closes when DHW NC 2-port opens. I also stop the UFH pump on DHW heating via a separate BDR91. For additional...
  10. Install GSHP before RHI payments stop? Evohome GSHP control

    Just had 1,200m2 of farmland returned to me. My daughter is tennis mad and would like a tennis court constructed.

    I figure it makes sense to prepare for the future and install a Ground Source...
  11. I see this same behaviour with my setup OpenTherm...

    I see this same behaviour with my setup OpenTherm + 4xHCE80.

    Nothing you can do about it I’m afraid. At low zone demands < 10% (24C) I observe the HCE80s TPI the UFH pump even though the boiler...
  12. Thread: X-Plan

    by kevinsmart
    Replies
    11
    Views
    1,370

    Ideally Evohome would allow you to set different...

    Ideally Evohome would allow you to set different max CH and DHW OpenTherm temperatures, but unfortunately it doesn’t. And with some boilers the default 80C or 90C is too high.
  13. Thread: X-Plan

    by kevinsmart
    Replies
    11
    Views
    1,370

    Sure, if you are happy with the same max flow...

    Sure, if you are happy with the same max flow temperature and boiler settings for both DHW and CH.

    In my weather compensation setup, I disconnect the outside temperature sensor on DHW heating,...
  14. Replies
    6
    Views
    1,199

    There is a nice description by DBMandrake here: ...

    There is a nice description by DBMandrake here:

    https://www.automatedhome.co.uk/vbulletin/showthread.php?6134-Evohome-firmware-02-00-19-31-Beta-Trial-Exclusive-for-Automated-Home-Members/page63
  15. Thread: X-Plan

    by kevinsmart
    Replies
    11
    Views
    1,370

    Evohome support of DHW priority has only just...

    Evohome support of DHW priority has only just been added to its firmware. Previously if you had CH and DHW valves you would wire them to the DHW BDR91 such CH closes when DHW opens.

    I’m not sure...
  16. Thread: X-Plan

    by kevinsmart
    Replies
    11
    Views
    1,370

    Because default operation is OpenTherm heating...

    Because default operation is OpenTherm heating with only HR91/2s controlling flow to radiators.

    When there is a demand to heat the DHW cylinder you don’t want 70C flow in your CH circuit leading...
  17. Thread: X-Plan

    by kevinsmart
    Replies
    11
    Views
    1,370

    Basically the CH 2-port is Normally Open and the...

    Basically the CH 2-port is Normally Open and the DHW valve Normally Closed.

    When there is a Priority DHW demand the CH valve is closed and DHW opens, so all flow is to the cylinder.

    With...
  18. Thread: X-Plan

    by kevinsmart
    Replies
    11
    Views
    1,370

    https://www.intergasheating.co.uk/app/uploads/2019...

    https://www.intergasheating.co.uk/app/uploads/2019/11/X-Plan-diagram-Rapid-HRE-Eco-RF-low-voltage-option-V1.pdf
    ...
  19. As I understand it, this parameter sets the...

    As I understand it, this parameter sets the closed to open, 0-100% (90 degrees) actuator time.

    What do you observe when there is a 100% demand, how long does it take to open the valve?
  20. Yes, looks like a bug, but does the default 150s...

    Yes, looks like a bug, but does the default 150s not work for you, why do you want to change it?
  21. Thinking back to how I set my HM80 up, Bruce. It...

    Thinking back to how I set my HM80 up, Bruce. It was on the older firmware and at that time after configuring the parameters, you needed to change the heating type from MIXING VALVE to ZONE VALVES,...
  22. Replies
    7
    Views
    884

    If there is no heating demand 0% then the boiler...

    If there is no heating demand 0% then the boiler won’t fire and the radiator valves won’t open.

    Try setting zone(s) 2C above the current temperature reading to test whether they heat up.
  23. Replies
    7
    Views
    884

    What zone heating demands do you see in the...

    What zone heating demands do you see in the Installer menu (long press Settings)?
  24. Replies
    69
    Views
    12,869

    Not now, I moved house and predominantly have...

    Not now, I moved house and predominantly have HCE80s now. It was working fine with the latest firmware as far as I recall but I was just using the default run time setting, I only changed the max...
  25. 1 is L red 2 is N blue 3 is switched L to...

    1 is L red
    2 is N blue
    3 is switched L to boiler yellow

    BDR91:
    Connect L and N
    Bridge L to A
    B to boiler yellow