  1. yes ... you seem to associate the "Single room /...

    yes ... you seem to associate the "Single room / Multi room" option to the "Temperature sonde" option, which are 2 different options in the zone configuration.
    I am wondering if this is correct, in...
  2. @DBMandrake, I am wondering about what you ar...

    @DBMandrake, I am wondering about what you ar saying, because the "Single / Multi Zone" and "Temperature sonde" are 2 different parameters in the "Zone".

    - "Température sonde" parameter is in the...
  3. ok, I am not having any issue, but just wondering...

    ok, I am not having any issue, but just wondering how I had set this configuration because I do not recall.
    So the right way to do it is to pair the first HR92 with the Evotouch in that zone, then...
  4. How did I configure 2 heaters in the same "room" ?

    HI there,

    I have an house with a Evotouch, 9 HR92's in 8 different rooms (the living has 2 HR92's working together to operate the 2 heaters in the same way), and a BDR91.
    I was just looking at...
  5. Yes, the Evotouch is set as the "ambiant...

    Yes, the Evotouch is set as the "ambiant temperature sensor" ... and you may be right as since I powered on the electricity again, still a few hours after, the "battery loading" icon was still on...
  6. Evotouch ambiant température is showing wrong ambiant / going in opposite direction

    Hi there,

    Today I had to power off my BDR91 to do some electrical works, my evotouch went on battery mode, and since I powered on again, I see the temperature of my living room (having 2 heaters)...
  7. ok, he definitely has an issue because turning...

    ok, he definitely has an issue because turning the black wheel clockwise is not getting any resistance, so I think it is unable to puch the pin into the TRV.
    He needs to change the TRV's I think.
    ...
  8. What you show there is the M28x1.5 or M30x1.5, I...

    What you show there is the M28x1.5 or M30x1.5, I have asked the guy to put it in the TRV and turn there black wheel clockwise, but he says it is not having any "resistance" so according what he says,...
  9. HR92 can not completely CLOSE the radiator valve

    Hi there,

    A friend of mine has an issue with 3 HR92's on 3 radiators where even if there is no demand and the HR92 is in sync with the evotouch and has a "0" position, the radiator continues to...
  10. Thanks a lot DBMandrake for the quick reply. So...

    Thanks a lot DBMandrake for the quick reply.
    So let me please rephrase in "my" English because I do not understand all your words.

    So I understand this is not possible to have 1 Evotouch acting...
  11. No way to have the HR92 commanding the BDR91

    Hi there,

    A friend of mine is not succeeding in setting up its unique HR92 commanding the BDR91.

    He has an evotouch in a room with radiators without HR92's .. in that room the Evotouch is...
  12. Evohome : Simple / Multi Zone + heater valve / Zone valve

    Hi there,

    I have an Evohome system with 8 zones defined and a total of 9 HR92's (2 of them are located in the same zone - living room), but I would like to support a friend who has issues with the...
  13. Thanks a lot ... my boiler is a gas with...

    Thanks a lot ... my boiler is a gas with condensation, it was initially set to 6 cycles / hour and worked like that for the last 3 years, but a month ago the boiler technician set it to 3.
    What are...
  14. Replies
    39
    Views
    16,487

    the phantom derogation if I am correct I was one...

    the phantom derogation if I am correct I was one of the first mentioning this uses and Honeywell even connected to my system remote to investigate.
    It was solved with a SW update, but this I am not...
  15. Replies
    39
    Views
    16,487

    I do not think so ... the "phantom derogation"...

    I do not think so ... the "phantom derogation" was an issue where there was LIKE a manual derogation done on the HR92 which was overriding the Evotouch hourly program.
    I do not think it has anything...
  16. Replies
    4
    Views
    658

    Hello, If I am correct you can configure the...

    Hello, If I am correct you can configure the stuff from 3 different ways :

    1. Configure 1 HR92 for 1 room
    2. Configure 2 HR92's being in the same room and control them as if they were 1
    3. there...
  17. Evohome : Cycles per hour parameter - what is that ??

    During the last maintenance of my heating system, the technician came and changed the advanced settings -> system parameters -> cycles / hour from 6 to 3, he told it was better without being really...
  18. Evohome : valve position status on the HR92 vs evotouch

    Hi there,

    Can someone please confirm to me what the valve position is supposed to show ?

    It looks like when the valve is completely opened, the HR92 menu shows "100", and "0" when it is...
  19. at the bottom right it is the chronometer...

    at the bottom right it is the chronometer appearing meaning there is a derogation ... (and obviously when THERE IS a derogation).
  20. Replies
    7
    Views
    1,657

    mmm my personal data seems correct with postcode...

    mmm my personal data seems correct with postcode 1070 for Brussels (Belgium) :

    1302
  21. Replies
    12
    Views
    1,718

    you mean you still have phantom derogation with...

    you mean you still have phantom derogation with that SW version ?
  22. Replies
    7
    Views
    1,657

    No outside temperature displayed ...

    Hi there, I just got a mail from Honeywell mentioning the phantom derogation issue I reported in April 2016 is solved, and I see I got latest FW version :
    update WiFi 02.00.17.00 and Application...
  23. Replies
    12
    Views
    1,718

    See my posts on phantom derogation - seems to be...

    See my posts on phantom derogation - seems to be solved in latest FW release update WiFi 02.00.17.00 and Application 02.00.17.03
  24. Replies
    106
    Views
    29,611

    CRAZY !!! We are September 2018, and I just got...

    CRAZY !!! We are September 2018, and I just got the following automated mail from honeywell ... 2 and an half year after issue reported !!!
    I can not check if issue is solved, because I had applied...
  25. CRAZY !!! We are September 2018, and I just got...

    CRAZY !!! We are September 2018, and I just got the following automated mail from honeywell ... 2 and an half year after issue reported !!!
    I can not check if "Phantom override" issue is solved,...