Search:

Type: Posts; User: mtmcgavock

Page 1 of 20 1 2 3 4

Search: Search took 0.01 seconds.

  1. On a sealed system such as a Pressurised cylinder...

    On a sealed system such as a Pressurised cylinder it's very unlikely to get Legionella, also the water would have to be heated constantly and not drawn off for long periods of time such as weeks...
  2. Replies
    10
    Views
    658

    Faulty wiring or stuck valve. Your volt pen...

    Faulty wiring or stuck valve.

    Your volt pen will show a live as they have a perm live going to them for the microswitch. You'd need to see if there's 240v on the Brown wire to the motor to work...
  3. Replies
    10
    Views
    658

    Yes they have a manual override. Some valves will...

    Yes they have a manual override. Some valves will stay perm open if you operate the lever. That maybe your issue, but hard to say if you don't know the make of valve. Maybe a picture might help?
  4. Replies
    10
    Views
    658

    You'd need to test if there's power to the valve,...

    You'd need to test if there's power to the valve, and check whether it's been locked open. Is it a Honeywell Valve?
  5. Replies
    10
    Views
    658

    Sounds like it's wired up wrong, especially as...

    Sounds like it's wired up wrong, especially as that the High Limit stat on the cylinder should be still wired in series with the zone valve. When the heatings calling it sounds as if it's heating the...
  6. Replies
    9
    Views
    984

    Don't think anyone really ever adheres to that...

    Don't think anyone really ever adheres to that rule :rolleyes:
  7. Replies
    9
    Views
    984

    So far i've resisted putting it back on. We've...

    So far i've resisted putting it back on. We've had the lounge rad on tonight (Beauty of Evo) and the Towel Rails come on as they would throughout summer. Hoping to get a few more days yet before the...
  8. Can you confirm which email or form you used? I...

    Can you confirm which email or form you used? I have a customers who's needs updating.
  9. Replies
    108
    Views
    16,392

    I've never had any issues with my own CS92A, only...

    I've never had any issues with my own CS92A, only when it needs new batteries. Other than that it's been perfect. I get the Comms error when the batteries are low, change em and it's good for another...
  10. Replies
    108
    Views
    16,392

    Oh no! Go Unvented and System boiler. Then you...

    Oh no! Go Unvented and System boiler. Then you can upgrade that Electric shower to something a bit better :D
  11. Thanks bruce_miranda. Even though I'm a...

    Thanks bruce_miranda. Even though I'm a 'MasterTech' Vaillant installer I get very few people requesting either Evohome or Vaillant Controls so haven't managed to get stuck into a project where I can...
  12. Replies
    15
    Views
    2,377

    Yeah, that's what I said. A cable back to the...

    Yeah, that's what I said. A cable back to the zone valve.

    This is obviously dependant where your zone valve is.
  13. Replies
    15
    Views
    2,377

    If you have an Unvented cylinder you will require...

    If you have an Unvented cylinder you will require a cable back to the zone valve. You cannot just use the Hot Water Kit to control the zone valve.

    The Cylinder High Limit stat is still required to...
  14. Replies
    5
    Views
    1,560

    Mine does this, however I usually find the...

    Mine does this, however I usually find the heating valve opens a minute or so later. But yeah it is rather annoying.
  15. I'd suspect with a grant you'll be very limited...

    I'd suspect with a grant you'll be very limited to your choices, and the quality of work you will probably get @DBMandrake won't to be up the standard you expect. They'll throw the thing in. They'll...
  16. Replies
    4
    Views
    1,138

    Yes it's probably fine, if you were to run at...

    Yes it's probably fine, if you were to run at 75oc and had the system on a full demand for a good hour or so then it might be a different story.
  17. Replies
    4
    Views
    1,138

    Depends what your precharge pressure in your...

    Depends what your precharge pressure in your expansion vessel is. I have a calculator that works it all out.

    At 65oc flow temp, with an expansion vessel pre-charge of 1.5 and a system fill of...
  18. Replies
    35
    Views
    11,097

    Did anyone come up with an easy solution to this?...

    Did anyone come up with an easy solution to this?

    I don't have any energy monitoring currently and would like to invest in one rather than go down the smart meter route.
  19. Replies
    9
    Views
    1,399

    Combi I take it? Hope it all goes well.

    Combi I take it? Hope it all goes well.
  20. Replies
    9
    Views
    1,399

    What boiler did you end up going for?

    What boiler did you end up going for?
  21. Replies
    21
    Views
    3,917

    Good old fashioned way of a Gate Valve cracked...

    Good old fashioned way of a Gate Valve cracked open 3/4 of a turn is the best thing IMO, then remove the top.
  22. Replies
    28
    Views
    5,213

    There's apparently a work around on the Plus...

    There's apparently a work around on the Plus System boilers - although i've never implemented it myself. How are you changing the set point using eBus? Some external device I assume.

    'Vaillant HW...
  23. Replies
    28
    Views
    5,213

    Does it work OK? At some point i'll probably...

    Does it work OK?

    At some point i'll probably be replacing my boiler with a Vaillant and wondered if it's worth the extra hassle.

    Did you manage to get it to differentiate between CH and HW like...
  24. Replies
    28
    Views
    5,213

    What you using to do that out of interest? a VR33?

    What you using to do that out of interest? a VR33?
  25. Isn't that the main idea behind it though?...

    Isn't that the main idea behind it though? Looking at the Slides on the beta, that seems to be one of the main reasonings.

    Because tbh, I rarely suffered from overshoots before.
Results 1 to 25 of 482