  1. yes, I checked Settings on Evo. I had a look...

    yes, I checked Settings on Evo.

    I had a look this evenining too. All rooms dropped 0.5C below the set point and for an hour the boiler didnt fire at all. The boiler demand was 51% this evening...
  2. Replies
    7
    Views
    1,178

    My intergas can modulate to 25c so im puzzled why...

    My intergas can modulate to 25c so im puzzled why max ch temp is demanded. Its also intermittent. Either incompatibility or a fault
  3. Replies
    7
    Views
    1,178

    Have you noticed for how long the boiler was...

    Have you noticed for how long the boiler was firing up. Was it 9min off 1 min on by any chance?
  4. Replies
    1
    Views
    596

    ive noticed that intermittently some HR92s stays...

    ive noticed that intermittently some HR92s stays open at 10% of stroke and may be calling for heat.
    But as far as I'm concerned call for heat should only happen when HR92 are opened to at least 25%.
  5. Replies
    1
    Views
    596

    Evohome - Heating requested by ghosts

    Hello,

    I remember seeing the issue in the past but I cannot recall the resolution.

    I've got Evohome (4 zones with Hr92) with Intergas via Opentherm.

    Ive noticed recently (but it might have...
  6. Replies
    14
    Views
    3,289

    Old thread but i just want to send a quick...

    Old thread but i just want to send a quick update.

    It appears the main reason why my rads were not getting hot was an issue with trvs.

    It appears that when there were open at 20-30 they were...
  7. Hello Ive got an intergas boiler too just a...

    Hello

    Ive got an intergas boiler too just a diffent model.from testing it appears that anticycle is ignored by opentherm from what ever reason.

    But this is only my personsl opinion
  8. Replies
    1
    Views
    650

    Best settings for zones

    Hello,

    Im looking for some tips how to use evohome and intergas xlusive via opentherm bridge most efficiently.

    I live in a 3 bedroom semi house. We have hr92 on every rad apart of hall and...
  9. Replies
    14
    Views
    3,289

    I found an answer to cycle rate. It is ignored...

    I found an answer to cycle rate. It is ignored due to ot being installed
  10. Replies
    14
    Views
    3,289

    Evohome + intergas xclusive. Low heat demand

    Hello

    I have been using evohome for over 2 years with an old ariston boiler via bdr91. It worked ok, however it was a time to replace a boiler and have chosen intergas exclusive paird via...
  11. Replies
    9
    Views
    3,235

    Hello, All seems to be working well. Thank...

    Hello,

    All seems to be working well.

    Thank you for your all your help.

    M
  12. Replies
    9
    Views
    3,235

    I have fully cycled all HR92 and adjusted...

    I have fully cycled all HR92 and adjusted lockshield valve on towel radiator so its barley open now, hopefully it will not steal the heat from other radiators.

    One thing I noticed is that on 2...
  13. Replies
    9
    Views
    3,235

    2 radiators are good 10 meters away from...

    2 radiators are good 10 meters away from eachother, second rad has standard TRV fitted. I may close the TRV on temporarly to stop confusing evo.





    I think you may be right here, bathroom rad...
  14. Replies
    9
    Views
    3,235

    Thanks I will give it a go properly tomorrow,

    Thanks I will give it a go properly tomorrow,
  15. Replies
    9
    Views
    3,235

    Evohome - boiler 6min on, 4min off and so on?

    Hello,

    I have installed evohome 2 days ago. Its seems to worked well yesterday however last night I noticed something strange.
    I have HR92 in 3 bedrooms, living room one radiator with HR92 and...
  16. Replies
    4
    Views
    2,772

    one more question please I plan to wire the...

    one more question please

    I plan to wire the BDR91 to Ariston Microcombi boiler could not find much information about this boiler.
    But by looking at the manual...
  17. Replies
    4
    Views
    2,772

    thank you for the reply

    thank you for the reply
  18. Replies
    4
    Views
    2,772

    Wiring BDR91 + Evo

    Hello,

    I have purchased new evo package with BDR91. I've had a look at the diagrams for wiring up BDR91 to combi boiler.

    Would it be OK to wire up BDR91 directly to the same power fused spur...