  1. We leave ours on 24/7 in Winter and Summer. The...

    We leave ours on 24/7 in Winter and Summer. The Evohome calls upon it whenever the radiators call for heat.

    A buffer tank, or thermal store, is a large cylinder with multiple tappings that allow...
  2. I have a similar arrangement with a Windhager...

    I have a similar arrangement with a Windhager boiler. It controls the loop between the buffer tank and itself and the Evohome system is the other side of the buffer. It works well and doesn't need a...
  3. Replies
    171
    Views
    75,084

    Just a couple of questions for Rameses: Are...

    Just a couple of questions for Rameses:

    Are the HR92's fully proportional, or are they controlled in stages? i.e. will they go to any point between fully open and closed, or do they just have a...
  4. Not sure if anyones asked for this so far? I'd...

    Not sure if anyones asked for this so far?
    I'd like to be able to simply set all zones at the same temperature.
    Yes, I know that defeats the whole purpose of Evohome zoning, but there are times...
  5. Replies
    187
    Views
    73,782

    I can see the need for basic balancing, but I've...

    I can see the need for basic balancing, but I've assumed that Evohome takes away the need for fine adjustment as the system itself effectively destroys any finely balanced system - or have I got this...
  6. Replies
    187
    Views
    73,782

    I find these discussions quite fascinating. I...

    I find these discussions quite fascinating. I think that we have two different worlds here, the old analogue one with a digital overlay and the demand for a very precise digital control of something...
  7. Replies
    187
    Views
    73,782

    "rebind everything maliciously." It's not that...

    "rebind everything maliciously." It's not that bad surely?
  8. Replies
    30
    Views
    14,150

    We installed Evohome in December at the same time...

    We installed Evohome in December at the same time as switching from oil to wood pellet, so it's difficult to compare costs. But as others have said, you do tend to crank the heat up further in the...
  9. Replies
    2
    Views
    2,395

    Yes, the green light stays on until the pump...

    Yes, the green light stays on until the pump shuts down. I'm turning the system off by using the quick action "heating off'. I've set it at the maximum cycle rate and minimum run time (12 and 1...
  10. Replies
    2
    Views
    2,395

    Evohome Boiler RElay

    I've had my Evohome system installed for a couple of weeks, just controlling the radiators to get used to it. The system has been working well.

    I didn't connect to the boiler as we were about to...
  11. Replies
    7
    Views
    6,498

    Thanks Chris By supply side I meant supply to...

    Thanks Chris

    By supply side I meant supply to radiators. I probably should have used the term "demand side.

    Interesting that you came to the conclusion that 24/7 running was wasteful. The specs...
  12. Replies
    7
    Views
    6,498

    Things have moved on since my original post, and...

    Things have moved on since my original post, and the elderly oil boiler is about to be replaced by a Windhager Biowin wood pellet boiler linked to a 300 litre thermal store. The installer is handling...
  13. Replies
    1
    Views
    1,568

    Evohome with Thermal Store

    Has anyone had any experience in fitting an Evohome system in conjunction with a thermal store?
  14. Replies
    1
    Views
    1,759

    Gravity or "pumped" tank

    Just a quick question. How can I tell whether a hot water tank is designed for use in a gravity or fully pumped system?
  15. Replies
    7
    Views
    6,498

    Bypass with Alpha Pump

    I have a sealed CH system with an Grunfos Alpha2L pump. There are TRV's on all radiators but no bypass fitted. I'm wanting to fit a Honeywell Evohome system and am realising that I probably should...