  1. So after some observation - It appears HW...

    So after some observation -

    It appears HW priority is just enabled - with no way to turn this on or off as you require. Can someone from Resideo confirm this?

    However think i've found a bug -...
  2. No it's included in the email as a new...

    No it's included in the email as a new feature....I suspect you need certain hardware for it to show, but I figured I had the right hardware to do it.
  3. EvoHome Beta 02.00.19.31 - HW Priority Setting

    In the welcome beta email it briefly mentions about HW Priority dependent on your system set up but doesn't really expand on this

    'And finallyÖ. Stored hot water priority and a hot water heating...
  4. Not sure it'll let you attach on a PM. If you...

    Not sure it'll let you attach on a PM. If you want I can PM you my email to send it direct if that's easier.
  5. Update arrived here. Turned Cold Weather...

    Update arrived here.

    Turned Cold Weather Boost On
    Turned Warm Weather shut down on.
    Adaptive Load Scaling - set to Partial.

    No sign of HW priority setting though, even though I have two 2...
  6. I have Optimisation turned on and it works great....

    I have Optimisation turned on and it works great. I suspect how well insulated your house is may have something to do with it, however mine works flawlessly to be fair.
  7. Also the email - The images are of relatively...

    Also the email -

    The images are of relatively poor quality and i'm struggling to see the graphs etc. Is it possible to get them sent out in a slightly better quality? (I'm guessing you don't want...
  8. Just had email too, my boiler is missing too. No...

    Just had email too, my boiler is missing too. No Glow Worms as a manufacture on list (Major boiler here in the UK too) Mine is an older model but still no manufacture. (So I've just put it down as...
  9. Replies
    3
    Views
    135

    Signed up :)

    Signed up :)
  10. Just applied, hope i'll get it as i'm an...

    Just applied, hope i'll get it as i'm an installer.
  11. Don't forget if you are using the HW kit with an...

    Don't forget if you are using the HW kit with an Unvented cylinder you need to leave the Hi Limit Stat wired in series with the BDR91 to comply with regs.
  12. Replies
    37
    Views
    1,034

    Yes on larger systems sometimes it isn't worth...

    Yes on larger systems sometimes it isn't worth fitting a System boiler as you have to start adding extra expansion vessels on, larger pumps anyway. However the system boilers are roughly the same...
  13. Replies
    37
    Views
    1,034

    On another note, if you have a 4 bed house, have...

    On another note, if you have a 4 bed house, have 2 or more bathrooms and want to run two showers at once ideally you should be looking at a System Boiler and Unvented Cylinder. A combi will never be...
  14. Replies
    37
    Views
    1,034

    Quite right, I was referring to a system boiler...

    Quite right, I was referring to a system boiler we fitted with an Unvented cylinder. Combis are a different matter - and you'll find on a combi it has two different outputs for HW and CH.
  15. Replies
    37
    Views
    1,034

    Biggest problem with most installers - put a...

    Biggest problem with most installers - put a biggest boiler in they can, resulting in upgrading the gas main when in reality most properties don't need it and would be more than adequate running a 15...
  16. Replies
    37
    Views
    1,034

    38Kw is huge for a heat only boiler really, do...

    38Kw is huge for a heat only boiler really, do you live in a mansion? :D

    I seem to recall you saying it was drastically oversized in the past....
  17. Replies
    8
    Views
    325

    Yes which I believe the OP is.

    Yes which I believe the OP is.
  18. Replies
    8
    Views
    325

    My parents runs this way, they have two boilers...

    My parents runs this way, they have two boilers that heat different parts of the system and one control system (Evohome) so I had to get a way round it and using the Electric option worked well.
    ...
  19. Replies
    8
    Views
    325

    Yeah set it to Electric Underfloor. It'll not...

    Yeah set it to Electric Underfloor. It'll not fire the Heating Relay then.
  20. Done many systems UFH systems with BDR91s and...

    Done many systems UFH systems with BDR91s and T87RFs paired up to the EvoHome panel and they work fine as a TPI zone. You either need a 4 wire actuator or a wiring centre of the underfloor. 4 Wire...
  21. Replies
    79
    Views
    4,577

    Ive used Evohome as a solution where it hasnít...

    Ive used Evohome as a solution where it hasnít been possible to get a wire to a cylinder cupboard with no power or easy route back to the boiler. Having said that it was probably easy to get a 240v...
  22. Replies
    20
    Views
    1,581

    I have HW priority on my system and it works...

    I have HW priority on my system and it works really well. Tbh any larger system it's well worth while IMO whether you've got adapting flow temps or not. You have to take into account the KW rating of...
  23. Replies
    79
    Views
    4,577

    Heating Off just does as it says, Heating Off. It...

    Heating Off just does as it says, Heating Off. It doesn't turn the HW schedule off, so if you are away it isn't useful unless you want a tank full of HW at home! :p

    But yes I agree, 5oc isn't high...
  24. Replies
    79
    Views
    4,577

    Without getting off topic I find 5oc is too cold,...

    Without getting off topic I find 5oc is too cold, i've adjusted my Away mode to 11oc - I find it a happy medium between it keeping the house aired and not coming on too often.

    Useful to know...
  25. Replies
    79
    Views
    4,577

    Laughably I've just had a Comms error after being...

    Laughably I've just had a Comms error after being away for 9 days. Turned system back on before we were heading home, glanced at the App to find our HW at 66oc! On return looking at the log there was...