I am assuming this is the right section to ask this! If I install a Worcester Bosch 8000 Life Combi am I right assuming I need an adaptor to use Opentherm?
Type: Posts; User: G4RHL
I am assuming this is the right section to ask this! If I install a Worcester Bosch 8000 Life Combi am I right assuming I need an adaptor to use Opentherm?
I am in a similar position. My boiler more and more produces greater noise like a dying pair of lungs. I am looking at Intergas but an Intergas system boiler. This gets rid of tanks in my loft and...
I am considering Intergas, but an Intergas system boiler with a vented or unvented tank driven by mains water pressure. I have in the last couple of days found an Intergas installer local to me. He...
You could could consider a thermal store vented or unvented for supplying hot water at mains pressure. I assume if one does that you don’t need DHW assigned in Evohome and leave it entirely as a CH...
Thanks. Will have a look.
Some months ago I took my Control Panel off it’s mount and noticed that within a couple of minutes it hung on me with the display saying the batteries in it were low and I needed to put it back on...
As said 1.01.
Nothing obvious but if I lift the display panel it reads “HR92UK 1.01” Then “1436 5 ST3”
I imagine 1.01 is it’s firmware. If anybody in the forum has recently bought an HR92 perhaps he or she...
I have no issues with the app.
My HR92s will be 7 years old this year. Are the current new HR92s the same as those of 7 years ago? I.e. no updates to them. It may be me but I think mine are getting noisier. Perhaps like me they...
All done following your kind response. As mentioned it appears I had not received the earlier request for info from me.
I did, apply for it that is, many many months ago but was not selected therefor.
Anybody know when the updated software will be rolled out? It is 9 months since this topic was started.
I get mine from Amazon. They are badged as Amazon. They don’t seem to last any longer or shorter than others and I have had no problems. I have a diary note to change them all on the 1st December...
I have done it on a more simple basis. My radiator in the conservatory is set to 5c, the minimum. This time of the year I can hear the boiler fire up in the night which will be because the...
Perhaps if Evohome was made to be compatible with HomeKit, there is nothing preventing that now, then an outside temperature sensor could possibly be configured in HomeKit to feed information back to...
For those of you running the beta software does it enable better control over the custom menu? I rarely use mine but this morning I decided to warm the house up a little sooner than it normally would...
Has it actually been released? I am on 02.00.17.03
I find that mostly my real outside temperature measured by my own sensor is within a degree of “internet” obtained temperatures. Currently my outside temperature is 4C. Dark Sky says it is 6C and...
It has been so long in the coming that the best answer is when you see a pink pig flying past!
Unfortunately I don’t believe it is a simple process but a costly one and at present using natural gas is cheaper than electrolysis. My own view is the government is better looking toward reducing...
If there are two radiators in the room you need one on each. As I understand it Evohome will not work as it should if you don’t fit a TRV to each radiator in the zone. An HR92 or its equivalent. The...
Yes it is, different that is. I understand unvented needs the cold water main taking straight to it and that means work on the cold water taps. Not practical in my case.The vented does not have this...
Installing an unvented cylinder may not be practical as I am advised radical changes to the incoming cold water feed are needed but none are needed with a vented cylinder it being a simpler...
My current system is an old gas boiler for heating and DMH. Working through a three-way valve. Evohome controls it all, sending messages when heat is needed or not. DHW is similarly set up with a...