Type: Posts; User: frankmalia
oh yes, I read it wrong and just tried it. Sorry.
Would be nice...
Alexa Method
“Alexa make my Living Room 21 degrees for 1 hour”
...
I'm sure you know but just incase. 4 main methods, without going down Alexa or IFTTT route
1 - Turn zone TRV knob to desired setpoint, problem with this is it runs until next schedule setpoint...
I've been using IFTTT, If outside temperature is above XX'C then enable eco,day off, away or custom. I use 14'C and enable ECO. I switch back to day off mode when temp drops below XX'C
This...
Set mine to partial the other day from full, same issue.
Can you not just increase setpoint to get it to kick manually. I think the load scaling seams to work quite well, less overshoots early on in the year when heating was on all the time. Was it not...
Unfortunately had to switch off cold weather boost last night. Setpoint was 20.5 and boosting. Controller outside temp was 14'C, looking at weather reports the lowest temperature yesterday was ...
The Evohome only does 12 zones, so you would want 7 zones for upstairs radiators(6x1TRV + 1x2TRV).. That means your downstairs can only have 5 zones max for your 9 radiators. So if that works the...
SteveP, Since it was hot yesterday, I still have one room that is shut down from last night, due to it not not dropping below the actual SP by 1'C( I think it needs to be this). That room is...
Andy
OK, been tracking this since early morning to late evening. Liams Room and Madisons room has been boosting when differential is less than 10'C and down to 4-5'C differential, I have not...
OK I am wondering why some of my rooms are boosting by 0.5C when temp difference to SP is only 9C. One room is not boosting when difference is 11C.
1529
Covid 19 is giving honeywell alot of Beta testers with F~~~ All to do, cause they stuck at home, they are all geeks ripping the arse out of EVOHOME. No chance of any bugs in general release then;)
Answering my own question, just noticed it was boosting while in day off mode, day off symbol changed to boost symbol
Just a quick question, do all of these new features work when I have DAY OFF mode active(or any of the other modes, Custom,eco,away), as most people will have DAY OFF active in present climate....
This cold weather boost needs some work.
I have sketched suggestion how I think it should work which would work good if possible, and allow user to calibrate to there house and there individual...
I'll let Andy the minion have look first remotely.. Then try that, as pretty sure not seen this before, and seen it 3 times in a day now. Plus I log my temps and SP, so would of seen this. I have...
Ok thats the third time my dining room has set the SP to 30'C, it is only doing in my dining room that I have noticed. It is only when optimising start is working, once the room is at its time...
Its not 10 degrees temp, it is 10Degree below setpoint so if your setpoint is 16'C and above, and your difference in outside temperature is 10'C then your room will boost if set.
I agree the...
Set Point Issue on one room.
Seen this twice now, my dining room keeps getting a Setpoint 30’C, this happen yesterday after software update and this morning while dining room was pre heating...
Cold boost working I think, see pics. got mine set to 0.5'C boost and it has change schedule setpoint up by 0.5C and placed the boost symbol on screen. Rooms selected for boost did not boost if SP...
My software has changed. Great.
Looking forward to seeing if over shoots can be settled down, might save me having to change a couple of older valves out.
Warm weather shutdown would be good, ...
Applied, hopefully get it...
I thinks its good, see the projects have reduced to three. That will allow 18 sensors to be logged so setpoint & actual of 9 zones of evohome. Perfect for me, 9 rads
I have it setup to log to...
I would use Y87RF in the room that you desire most comfort, maybe living room, or if you have any radiators in rooms you use alot that the hr92 could have free air movement blocked due to radiator...
https://getconnected.honeywellhome.com/en/sites/getconnected.honeywell.com.en/files/evohome%20Installation%20Guide%20-%20gateway%20model.pdf
page 14 and 17 should allow you to install all...