Search:

Type: Posts; User: Andehh

Page 1 of 3 1 2 3

Search: Search took 0.00 seconds.

  1. Replies
    6
    Views
    1,855

    Thank you! I have very similar desires for our...

    Thank you! I have very similar desires for our renovation and whilst we could (& probably still will) run extra Wires, a wireless network smarthome type of setup is my current preferred option!...
  2. Replies
    6
    Views
    1,855

    I've come across this as I'm in a similar...

    I've come across this as I'm in a similar starting location. Did you ever proceed with this project?
  3. Is this it here? ...

    Is this it here?

    https://www.smartthings.com/gb/products/honeywell-evohome-connected-thermostat
  4. Thanks very much for coming back to us Andy! :) ...

    Thanks very much for coming back to us Andy! :)

    FWIW, as we progress through selling & moving house I have spent the last few days research alternatives to Evohome over concerns it is falling...
  5. Replies
    7
    Views
    1,094

    I don't believe so! I have come across the...

    I don't believe so! I have come across the scenario you described though; time based modulation? ie very low heat demand and the boiler cannot output a heat level 'that low' - therefore it turns...
  6. Replies
    7
    Views
    1,094

    Thanks very much, appreciate your feedback. I...

    Thanks very much, appreciate your feedback.

    I have pulled the batteries and reset everything and will keep an eye!
  7. Replies
    7
    Views
    1,094

    Room 4 had a 15% demand as well (apparently...

    Room 4 had a 15% demand as well (apparently deleted this line item by mistake) but all rooms were set to 15 degrees and were 24+ degrees in reality.

    15% heat demand reading received from the...
  8. Replies
    7
    Views
    1,094

    Evohome - phantom demand from Open Therm.

    As per title, system has been installed and working fine for last couple of years.

    Ideal logic combi boiler, evohome and 2 HCE80.

    Middle of the night the boiler powers on as 15% heat demand...
  9. Replies
    8
    Views
    1,280

    Just as an update, removing the T87RF2033 from...

    Just as an update, removing the T87RF2033 from one of the UFH zones seems to have resolved the issue. Desbite it looking & working fine, when left unattended it seemed to send an errant heat demand...
  10. Replies
    5
    Views
    1,342

    I have had a t87rf in my bathroom for the last...

    I have had a t87rf in my bathroom for the last couple of years without issue. Never really thought about it to be honest!
  11. Replies
    1
    Views
    531

    ....and with the system setup with me Binding on...

    ....and with the system setup with me Binding on the 'orange' flashing light (which gives me a solid Orange light on zone at the 'end' of binding, as opposed to binding on the 'red' flashing light...
  12. Replies
    1
    Views
    531

    Bindings Mixed up?

    I have two Zones of UFH; Kitchen & Bathrooms. When I Turn on the kitchens, Zone 1 lights up on the HCC80R as expected, and the flow valves open for Zone 1. It shuts off no problems afterwards....
  13. Replies
    10
    Views
    1,746

    Another thank you from me to DBMandrake, a very...

    Another thank you from me to DBMandrake, a very interesting read & helps me understand a bit more about the system!
  14. Replies
    8
    Views
    1,280

    Factory reset the HC880R. Left it - No heat...

    Factory reset the HC880R. Left it - No heat demand, system stayed off.

    Tried re-binding the individual dial controllers....one seems to work fine...the other one though....!!! Within minutes of...
  15. Replies
    8
    Views
    1,280

    Installer retired a year ago it when I last spoke...

    Installer retired a year ago it when I last spoke to him about another job.

    I have checked out the Zone valve on the UFH loop and it looks to be working fine. Actuator, motor all seems to be...
  16. Replies
    8
    Views
    1,280

    Thanks Paul, grateful for your post! With mine...

    Thanks Paul, grateful for your post!

    With mine the system is heating up though, my UFH Controller lights up, opens the flow valves and the UFH all warms up.

    Could the Zone valve have failed...
  17. Replies
    8
    Views
    1,280

    could it be a failed zone valve? All three seem...

    could it be a failed zone valve? All three seem to actuate as normal with the lever, I also don't get how a failed zone valve would cause the UFH controller +manifold to light up & engage? Though I...
  18. Replies
    8
    Views
    1,280

    HELP - System running with no control?

    We have had an Evohome installation for 3-4 years now, no big issues to speak of.

    We came home from a weekend away with the system set to 'away', my wife adjusted some of the rooms (2 x UFH zones...
  19. Replies
    106
    Views
    29,693

    I'd love that as well, currently using 'Conrad...

    I'd love that as well, currently using 'Conrad Connect' though. Beautiful interface that really helps show off your system & how it is working for you with graph, bar charts, history of it all etc....
  20. Replies
    39
    Views
    14,398

    Mine all lasted about 18 months, and I waited for...

    Mine all lasted about 18 months, and I waited for them to die fully, then bought a big pack of the high capacity Amazon rechargeable ones. Figure when the battery drops low, ill whip them out, charge...
  21. Replies
    106
    Views
    29,693

    Very pleased to see these features coming! ...

    Very pleased to see these features coming!

    Thanks for the continued support. :)
  22. Replies
    73
    Views
    21,600

    Likewise for me, 10.44am!

    Likewise for me, 10.44am!
  23. Replies
    73
    Views
    21,600

    Just having a fiddle with this, on first pass it...

    Just having a fiddle with this, on first pass it looks good! Ability to graph everything and understand the response times of each room depending on the current/requested temperature.

    How do I...
  24. Replies
    16
    Views
    7,654

    You are not wrong! It isn't needed, but then a...

    You are not wrong! It isn't needed, but then a 1000 system to control the house heating isn't needed either - far from it.... but when you buy the Rolls Royce of something, you expect the Rolls...
  25. Replies
    16
    Views
    7,654

    Evohome - Tracking/Graphing Temperatures

    I know this has been asked before & I know there are several work arounds, but just for the sake of continued pressure on Honeywell.... my parents who I installed & setup Evohome for have asked (&...
Results 1 to 25 of 57