  1. Not wanting to send/control, just passively...

    Not wanting to send/control, just passively monitor for debugging purposes - the log screenshot shown in the git repo is exactly what I'm looking for. You may recall I found software that worked with...
  2. Wow, this script is worthy of a thread of its...

    Wow, this script is worthy of a thread of its own.... Time to get a cc1101 and ardino.... :)

    Apart from the git repo are there any other threads here or on other forums discussing your software ?
  3. Replies
    3
    Views
    150

    I presume you meant a message pops up on the HR92...

    I presume you meant a message pops up on the HR92 itself with the zone name when you press the button - as I've never seen a message appear on the evotouch panel in response to pressing the button on...
  4. Opentherm is a two way protocol. The boiler can...

    Opentherm is a two way protocol. The boiler can send a lot of information to the thermostat, it's not just about the thermostat telling the boiler what to do. One of those things is a maximum allowed...
  5. Yes that was my point. Ultimately the user...

    Yes that was my point.

    Ultimately the user should be in control of deciding the absolute maximum flow temperature, regardless of whether weather compensation is in use or not. If the OpenTherm...
  6. You seem to be reading and responding to...

    You seem to be reading and responding to something that I didn't actually say.

    I didn't even refer to weather compensation at all. I actually said "is it Evohome or Intergas responsible for the CH...
  7. Replies
    3
    Views
    218

    Are you sure you mean the HR92 valve position (by...

    Are you sure you mean the HR92 valve position (by going to option 10 in the HR92 itself) or do you mean the heat demand for the zone reported in the system devices page in the installer menu on the...
  8. Charging the batteries probably generates...

    Charging the batteries probably generates additional heat but if the unit is left on the charger the batteries are rarely charging as they sit fully charged most of the time.

    The always on display...
  9. Replies
    22
    Views
    1,292

    The hot water control does indeed have frost...

    The hot water control does indeed have frost protection although I believe it activates at 5C not 10C.

    Your cold water supply must be very cold, I've never seen it trigger on my system! A couple...
  10. Nice one! :) I guess this quote answers the...

    Nice one! :)


    I guess this quote answers the long debated question - is it Evohome or Intergas responsible for the CH flow temperature control not functioning with OpenTherm control, with each...
  11. Replies
    22
    Views
    1,292

    Minimum hot water temperature is set indirectly...

    Minimum hot water temperature is set indirectly by changing the differential. Minimum = setpoint - differential, so increase the differential number.

    Keep in mind that if the minimum temperature...
  12. Replies
    40
    Views
    910

    5kW minimum output without cycling is still a lot...

    5kW minimum output without cycling is still a lot for spring/autumn. Even if anti-cycling doesn't kick in in the middle of the winter I'd expect that you'd see it in the warmer months when the house...
  13. Jump to the last post in my Valencia thread -...

    Jump to the last post in my Valencia thread - with Stroke set to 1 I've been happy with their performance on an HR92.

    I can't comment on how they will perform on an HR91 as I didn't have the...
  14. Unfortunately, yes. The HR91 has a fixed...

    Unfortunately, yes.

    The HR91 has a fixed "calibration" setting of about -2C (or it might be -3C, can't remember as it's a while since I tested one) so it sends a temperature reading that is 2-3...
  15. Replies
    20
    Views
    945

    The controller is fine - no issues with any other...

    The controller is fine - no issues with any other devices. The CS92A is just poorly implemented IMO.

    My original one was far worse, the replacement one has been a lot better, (but not problem...
  16. Replies
    20
    Views
    945

    Checked the signal - 4 flashes out of 5. ...

    Checked the signal - 4 flashes out of 5.

    Checked the battery voltage - both cells are 1.496 volts. Perfectly normal for an Alkaline battery (still about 80% life left) but down into the range...
  17. Replies
    20
    Views
    945

    Depending on when it happens, a loss of comms...

    Depending on when it happens, a loss of comms causes me one of two problems.

    1) If it happens while hot water is off, the system will refuse to heat the hot water -> cold water
    2) If it happens...
  18. Replies
    20
    Views
    945

    Me too, better (the first one was totally...

    Me too, better (the first one was totally unusable) but not problem free by any stretch.

    My experience as well. Brand new batteries at 1.6v each seem to work OK (at least for a month or two) but...
  19. Replies
    20
    Views
    945

    Once again I have a problem with the hot water...

    Once again I have a problem with the hot water sensor on my system. :( The CS92A is definitely the most unreliable part of an Evohome system.

    Not sure what the cause is yet as I'm at work but I...
  20. Replies
    4
    Views
    191

    If all zones are suddenly reporting errors then...

    If all zones are suddenly reporting errors then normal deduction would say that either there is massive signal interference from something (unlikely to that extent) or the radio in your controller...
  21. I agree that an adjustment in the menu to cope...

    I agree that an adjustment in the menu to cope better with the different characteristics of different valves would be helpful, although technically there already is one - the Stroke setting....
  22. To be fair to Honeywell, after first encountering...

    To be fair to Honeywell, after first encountering these problems and studying them and how the system works I've thought a lot about the issues of trying to proportionally control the water flow of a...
  23. To get closer figures it just takes a bit of...

    To get closer figures it just takes a bit of patience, waiting while it makes gradual changes in response to room temperature changes and then rechecking option 10.

    I checked my Living room...
  24. Replies
    22
    Views
    1,292

    Any hints as to what you mean by "Zone Scaling" ?...

    Any hints as to what you mean by "Zone Scaling" ? I can think of more than one possible interpretation of that...
  25. Replies
    12
    Views
    649

    https://www.youtube.com/watch?v=jYcPBE5PXhs :D

    https://www.youtube.com/watch?v=jYcPBE5PXhs

    :D
Results 1 to 25 of 500