  1. Did you have a manual override on a zone at the...

    Did you have a manual override on a zone at the time, looks like Bathroom was? - current bug. I found it within 5 minutes of mine updating :p

    When a manual override to a zone is present HW isn't...
  2. Warm Weather has been acting a bit strange on my...

    Warm Weather has been acting a bit strange on my system today - or at least it appears so. I've been pottering around in the garage and the heating relay keeps coming on - on further investigation...
  3. It shows the status of heating within little...

    It shows the status of heating within little Cylinder on the display next to the HW temp - fully coloured in means HW heated (Solid Red), Flame symbol within the cylinder symbol means currently...
  4. You are right, when I checked the demand all...

    You are right, when I checked the demand all zones were showing as 0% before - but i'm not sure if that was because the feature had kicked in and switched them to 'off' (They show as like you've set...
  5. Warm weather is working on my system too today -...

    Warm weather is working on my system too today - all zones as showing as off currently. TPI based system.
  6. All valid points and can see where you are coming...

    All valid points and can see where you are coming from, don't think we're taking this out on you :p Really appreciate your answers and support through the forum. But surely is it that hard to add a...
  7. Think you’ve misunderstood me too - I was meaning...

    Think you’ve misunderstood me too - I was meaning when there’s a HW demand and no CH demand. You don’t want the CH valve open on timer then, during a dual demand (HW & CH) then yes you’ll want both...
  8. Just for feedback - no issues with set points at...

    Just for feedback - no issues with set points at my end so far.
  9. Thanks, yes it's something I need to do as had...

    Thanks, yes it's something I need to do as had been thinking it for a long time and it looks like a few members have done this.

    Mines a little more complex though, as I have 2 heating zones (Rad...
  10. All my rads have HR92s too, so I think a timer on...

    All my rads have HR92s too, so I think a timer on my Heating MV would just be sufficient for when there’s an overrun from a heating demand - any pointers for what timer you used?

    I use a 2 minute...
  11. Surely with this though in the summer you get...

    Surely with this though in the summer you get heat into any rads with no HR92s?

    It is something i'm going to have to implement though, i'm just getting a lot of wasted heat - my rad in my garage...
  12. Couldn’t have put it better myself. I hope...

    Couldn’t have put it better myself.

    I hope Andy you can see my concern now that this feature needs to be something that could be turned on or off. Not every system is suited for HW Priority,...
  13. I would agree with you on this one, i've been...

    I would agree with you on this one, i've been thinking for a while to wire some timer into the MV for heating to hold it open after been energised - allowing for the heat to the rads rather than the...
  14. Yes but with OT theres a demand, so the pump is...

    Yes but with OT theres a demand, so the pump is pumping somewhere - on a TPI cycle the BDR91 unlatches and closes the Heating MV and therefore it's just pumping round the bypass. So all the useable...
  15. My point being that i've not seen any improvement...

    My point being that i've not seen any improvement levels in terms of comfort to warrant the extra cost of running/wear on the pump to be running all day at this current time, admittedly that may...
  16. Direct to Andy The Minion via email. I suggest...

    Direct to Andy The Minion via email. I suggest you PM him, as I think it's ludicrous you can't turn it off.

    I'm going to get a lot of phone calls when this update officially rolls out :rolleyes:
  17. To reiterate that, my pump overrun hasn't stopped...

    To reiterate that, my pump overrun hasn't stopped running all day nearly due to the short runs of a few minutes which kicks in the 5 minute overrun. Giving the learning the benefit of the doubt at...
  18. Been trying to tell them that.......but it was a...

    Been trying to tell them that.......but it was a decision made by the 'sales' team. Needs to be made for On/Off. The amount of systems it'll not suit....well I could go on. Many systems i've done...
  19. Think it would have been nice to have an On/Off...

    Think it would have been nice to have an On/Off option though, especially when it's enabled by default. Least before you had the option of wiring the system as such.

    As discussed with Andy;...
  20. You're quite correct, I had misread/misunderstood...

    You're quite correct, I had misread/misunderstood that point. That's why i'm finding it behaving oddly - I have my set points quite high, 21,22,23 in different areas. Knowing that now, yes ideally...
  21. Have to say the Cold Weather boost here too isn't...

    Have to say the Cold Weather boost here too isn't working well, finding the 10oc outside set point is too high for the Cold Weather Boost to kick in and is boosting zone unnecessarily. Needs to...
  22. Still on my Beta Firmware.....

    Still on my Beta Firmware.....
  23. Yes my view too. I could have fitted a new boiler...

    Yes my view too. I could have fitted a new boiler when we moved in however I've now had 3 trouble free years out of the Glow Worm. When you consider a new boiler will only last between 10-15 years, I...
  24. Funnily enough my fan is a bit noisy too! However...

    Funnily enough my fan is a bit noisy too! However it is the second fan (We used to do the maintenance on the house before I bought it) so the fan is about 7 years old. The advantage of living on an...
  25. So if you've got a heat demand on any of the...

    So if you've got a heat demand on any of the zones that aren't HW, when the HW calls for heat it shuts down the 'Heating' BDR91 and opens the BDR91 for the HW. HW reheats and then the Heating BDR91...