  1. I’d always recommend using OpenTherm if you can,...

    I’d always recommend using OpenTherm if you can, sounds like your installer is not familiar with its benefits.
  2. Iíd vote for Intergas too, I fitted one in my...

    Iíd vote for Intergas too, I fitted one in my last house. Or an Atag.

    Iíve inherited a Vokera in my new house. Out of the box it would default to 80C max flow temperature, so Iíve used an OTGW...
  3. Sounds like this is DHW preheat, have you tried...

    Sounds like this is DHW preheat, have you tried setting it to Eco?

    ► P-on (Program on):
    The appliance's DHW comfort function is switched on continuously within the chosen time slots. In this mode...
  4. 1788 1789 Here are all the types of requests...

    1788
    1789

    Here are all the types of requests seen by my OTGW. You can see there are a bunch of them with a period of around 1m45s.

    The DHW ones are odd, because Evohome doesn't distinguish...
  5. Replies
    3
    Views
    219

    Great. Might be useful to understand typical...

    Great. Might be useful to understand typical electricity consumption/costs too.
  6. Bruce, how often does the Evohome controller...

    Bruce, how often does the Evohome controller communicate with the OTB? Maybe that frequency has changed and that influences how often the OTB reads boiler parameters. There are several other...
  7. From my previous house with Intergas boiler. The...

    From my previous house with Intergas boiler. The Intergas boiler returns fractional temperatures, its sensor was very accurate according to my Netatmo weather station.

    01:42:24.375260 T001B0000 ...
  8. Yes, that's right, approximately every 1m 45s. ...

    Yes, that's right, approximately every 1m 45s. It's not OTGW initiated, it is coming from the OTB (T for Thermostat, B for Boiler):

    00:01:06.465029 T001B0000 Read-Data Outside temperature:...
  9. It's worked well for me in both a radiator and...

    It's worked well for me in both a radiator and now a UFH setup. I can hardly believe that the previous owner of my house had the UFH TMV set to 75C with a boiler temperature of 70C. Now, in this...
  10. Replies
    3
    Views
    219

    Out of interest Vaughn, what is your setup? I...

    Out of interest Vaughn, what is your setup? I see myself eventually going down the GSHP route. My house was originally going to have one fitted but the previous owner heard negative feedback from...
  11. Stick an OTGW between the OTB and VR33? That...

    Stick an OTGW between the OTB and VR33? That should tell you whether the Domoticz->HGI80->OTB path is working, returning the same value.

    We know OTB->Boiler->Outdoor sensor works. The OTB...
  12. Replies
    49
    Views
    5,356

    Yes, this initially confused me as well. A 10C...

    Yes, this initially confused me as well. A 10C request is used by Evohome to signify off, but by default, if CH Enable is on, it will be interpreted by my boiler just like any other request below...
  13. Heat Pumps are supported by the latest firmware...

    Heat Pumps are supported by the latest firmware and new BDR91T
  14. Replies
    99
    Views
    20,266

    I think it’s displaying the flow temperature...

    I think it’s displaying the flow temperature request (control setpoint).

    So if your current flow temperature exceeds this temperature, the boiler remains off but may continue to pump/overrun for...
  15. Replies
    49
    Views
    5,356

    So it turns out, after all that, that floor...

    So it turns out, after all that, that floor heating mode doesn’t work very well for my setup.

    In this mode the boiler appears to reduce its hysteresis from +5/-5 to +2/-2C.

    What this means,...
  16. Replies
    11
    Views
    656

    Maybe they changed the firmware, my Nest V2 never...

    Maybe they changed the firmware, my Nest V2 never pulsed, just appeared to stay off far too long. OpenTherm will improve matters if your boiler is compatible.
  17. Replies
    11
    Views
    656

    Yes, Evohome

    Yes, Evohome
  18. Replies
    11
    Views
    656

    There’s an explanation here: ...

    There’s an explanation here:

    https://support.google.com/googlenest/answer/9250165?hl=en-GB#zippy=%2Chow-true-radiant-works

    Whereas with Honeywell TPI where there is a regular on/off cycle when...
  19. Replies
    11
    Views
    656

    I donít think Nest employs TPI in the same sense...

    I donít think Nest employs TPI in the same sense as the CM927, switching on/off in 10 minute intervals.

    But itís True Radiant algorithm does learn how long your room takes to heat up or cool down...
  20. Replies
    49
    Views
    5,356

    I’ve added my OTGW controlled Arduino relay to...

    I’ve added my OTGW controlled Arduino relay to switch my boiler between standard heating (40-60C) and floor heating (20-39C) modes. Appears to work well.

    Conveniently the OTGW has 4 pins above...
  21. Replies
    455
    Views
    64,321

    What’s worked for me in the past is to go to the...

    What’s worked for me in the past is to go to the mytotalconnect web interface, delete your location and add it again. I think that resyncs.
  22. Replies
    455
    Views
    64,321

    I think rebooting your controller by pushing the...

    I think rebooting your controller by pushing the batteries apart should remove the phantom zone.
  23. Replies
    49
    Views
    5,356

    Vokera Unica, and LPG, unfortunately Bruce. Will...

    Vokera Unica, and LPG, unfortunately Bruce. Will probably make do with it until the time is right to fit a GSHP.
  24. Replies
    49
    Views
    5,356

    I learned that my boiler’s floor heating jumper...

    I learned that my boiler’s floor heating jumper tag setting is actually dynamically read.

    If the jumper is inserted, OpenTherm will switch from a 40-80C range to 20-45C.

    So, I’m going to...
  25. Replies
    24
    Views
    1,792

    For a gas boiler, I would set to 6 cycles per...

    For a gas boiler, I would set to 6 cycles per hour, 1 minute minimum.