  1. Well, beta? My Evohome was delivered a month ago...

    Well, beta? My Evohome was delivered a month ago with FW version 19.31. That version had the Smart Features. Elsewhere on this site it turns out that 19.31 is a beta version. It looks like Honeywell...
  2. Well, at least now you know you have to be...

    Well, at least now you know you have to be careful not to select that you don't want to see them anymore :D
  3. Ehhh, (short) press ' Settings', then select...

    Ehhh, (short) press ' Settings', then select 'Smart Features' ? ;)
  4. Exactly what I saw earlier. So no OT for me until...

    Exactly what I saw earlier. So no OT for me until that is fixed.

    Ah well, I think on/off works just as well, taking into account the boiler then also modulates its heat output to the set (55C)...
  5. Set it to partial and yes, the boiler heat demand...

    Set it to partial and yes, the boiler heat demand increased immediately. Looks like it now translates the heat request of the office (84%) 1:1 to the boiler again.

    About OT and load scaling, does...
  6. This weekend the temperature in our living zones...

    This weekend the temperature in our living zones (three zones that are connected and share the same temperature setting) was 0.5C too low, and noticeably so. Increasing the setpoint increased the...
  7. It reaches the target temp later and then more or...

    It reaches the target temp later and then more or less keeps it:

    1672

    The optimal start time is set to 3 hours. By the graph it looks like the office heats up nicely for 2 hours after which it...
  8. After only two days load scaling behaves...

    After only two days load scaling behaves exemplary. No more 100% boiler requests just to heat up a bathroom. Out of my 11 zones only one still undershoots. This is always a difficult room (office)...
  9. Press and hold settings for a couple of seconds,...

    Press and hold settings for a couple of seconds, acknowledge the warning and select ' System summary'. You can see the per-zone heat demand as well as the resulting total demand from the boiler.
  10. Replies
    7
    Views
    271

    Thanks for pointing that out, I never new I could...

    Thanks for pointing that out, I never new I could change the offset. Also nice that the offset can be above 0 for a boost. Completely perfect would be if I could select the zones that eco/boost...
  11. Three weeks ago I installed a new Evohome...

    Three weeks ago I installed a new Evohome controller and it came with version 19.31. Last Saturday I requested the beta via the Honeywell webform. I received a mail to verify my request on Monday and...
  12. Good explanation. Much clearer than the official...

    Good explanation. Much clearer than the official one I read in the Residio mail after asking for the beta. Thanks!

    I'll set load scaling to 'Normal', give it a few days and see what happens. BTW,...
  13. So scaling does not do away with the 'ask for...

    So scaling does not do away with the 'ask for 100% as soon as a setpoint differs more than 1.5C' using an R8810? That is a pity as that might solve the problem I raised elsewhere on this site. One...
  14. 19.33 was installed yesterday and the hallway...

    19.33 was installed yesterday and the hallway zone is now behaving as expected; the setpoint only rises to the set temperature. Nice!

    One question about the 'advanced load scaling' option: does...
  15. I requested the beta with Honeywell. Let's see if...

    I requested the beta with Honeywell. Let's see if that updates it to 19.33.

    Oh, and by the way, this forum seems to be more prudish than my grandmother; the intensifier I used to emphasize how new...
  16. Ah, seems I found an answer for this problem...

    Ah, seems I found an answer for this problem elsewhere in this forum. For some reason my brand-******** new Evohome controller has a beta FW version that exhibits this problem. Should be repaired in...
  17. Replies
    11
    Views
    476

    Ah, so. Well, then it will be the OpenTherm...

    Ah, so. Well, then it will be the OpenTherm monitor for me. I'm not planning in keeping it in between indefinitely; just for some time to find out what goes on (and wrong) between Evohome and Remeha....
  18. Replies
    11
    Views
    476

    Is Ebus fully compatible with OpenTherm?

    Is Ebus fully compatible with OpenTherm?
  19. 1) AS: 02.00.19.31, WiFi: 02.00.17.00 2) I'm...

    1) AS: 02.00.19.31, WiFi: 02.00.17.00

    2) I'm graphing the temp data with a home automation system, Domoticz. This basically gets these temperatures every couple of minutes from Honeywell via my...
  20. Replies
    11
    Views
    476

    Yes, sorry for the misunderstanding. I was aware...

    Yes, sorry for the misunderstanding. I was aware the monitor itself needs power; my question was regarding the R8810, will that still be bus powered by the monitor. Reading back not a very smart...
  21. Why is the setpoint way over the set temperature?

    As part of me catching up with the latest Evohome I have a question.

    Ever since installing the new Evohome controller I notice that one of my zones gets a higher setpoint than necessary. This zone...
  22. Replies
    11
    Views
    476

    By the looks of the setup of Jack007 the R8810...

    By the looks of the setup of Jack007 the R8810 still gets its power via the monitor. I'll go and order it and then replace my on-off BDR91.
  23. Replies
    11
    Views
    476

    Power stealing and OpenTherm gateway

    Hi,

    Does anybody know what happens to an Evohome R8810 when I put an Opentherm monitor between it and my boiler?

    I guess it keeps on working but would like to know for sure before I order the...
  24. Replies
    6
    Views
    336

    Apparently :-) I replaced my (sticky) 2013...

    Apparently :-)

    I replaced my (sticky) 2013 Evohome wall unit with the latest invocation two weeks ago and did not realize that this had changed. I presume that Evohome retrieves the outside temp...
  25. Replies
    6
    Views
    336

    Does Evohome do weather compensation? I...

    Does Evohome do weather compensation? I understood from Honeywell themselves (albeit years ago, ~ 2013) that this was not the case. Back then I bought an expensive outdoor solar- and temperature...