Search:

Type: Posts; User: osprey

Page 1 of 2 1 2

Search: Search took 0.01 seconds.

  1. Replies
    0
    Views
    910

    Solar Switch choice

    I have a 5kW PV array

    Installers recommended buying a Solar diverter switch to dump excess power into my Domestic HW
    They tried to sell me an Immersun unit ... these seem pretty good .... but...
  2. Replies
    11
    Views
    10,045

    It was a mixture of bits here and several posts...

    It was a mixture of bits here and several posts on this forum ...
    All phones working great.

    One of the key factors is that test have been carried out that show having a 3rd wire 'pin 3 ringing' ...
  3. Replies
    11
    Views
    10,045

    Thanks Keith .. I think the Tech sheet of the...

    Thanks Keith ..

    I think the Tech sheet of the manufacturer was mixing up BT socket & plug numbering ...
    I finished my CAT 5 termination today and all works perfectly.

    For ease of use I have...
  4. Replies
    11
    Views
    10,045

    Tim ... Not using secondary - using RJ45 outlets...

    Tim ...
    Not using secondary - using RJ45 outlets (no components) and LAU pbx master adapters.
    Advice I had from several guys was that a standard single microfilter can limit the REN capability once...
  5. Replies
    11
    Views
    10,045

    You have misunderstood ... I have already bought...

    You have misunderstood ... I have already bought RJ45 to BT adapaters ... they are the LAU master PBX detailed in the post
    i.e. http://www.molexpn.co.uk/products/pdf/AAA.pdf
  6. Replies
    11
    Views
    10,045

    Phones to Structured wiring Q

    Completed my CAT 5 terminations T568B (ignore DSL side of things for this post)

    I have ‘paralleled’ off a number of ways as per the helpful picture posted here, so as long as I plug my filtered...
  7. Replies
    3
    Views
    2,404

    That number shows as a secondary not PABX master...

    That number shows as a secondary not PABX master ... or did you just mean the Pro Signal range ?
  8. Replies
    3
    Views
    2,404

    Any LAU better than others ?

    Coming to the end of my structured wiring hook up.

    For POTS will be patching pins 2 & 5 from NTE5 to the patch panel .. and then at each outlet 'patched' will use a local LAU - Pabx Master to...
  9. Replies
    7
    Views
    3,879

    I have already bought the Vitellec crimp on CT100...

    I have already bought the Vitellec crimp on CT100 connectors, and having also invested in crimp tool won't be changing the system.
  10. Replies
    7
    Views
    3,879

    I agree on the cutting dielectric is easy enough...

    I agree on the cutting dielectric is easy enough ... just seems strange that it goes to the bother of cutting it to a set length that is no good for CT100 ??
  11. Replies
    7
    Views
    3,879

    Any CT100 experts out there ??

    After initial problems getting correct CT100 crimp tool - decided to make a start.
    I am slightly confused by the use of a 3 step coax stripper tool.
    I bought this, and the little beast creates a...
  12. Replies
    6
    Views
    19,729

    Re: Phone line connections at Patch panel

    Looking at the options then -

    I could fit a 'lower half' filter to my NTE5 at BT incoming... and patch a CAT5 cable to back of this ... at the other end of the cable in Node zero connect this...
  13. Replies
    3
    Views
    2,733

    Re: Supplier for cable tray

    Superb ... I checked their catalogue and couldn't see any ... I'll pick some up, go to local branch frequently
  14. Replies
    3
    Views
    2,733

    Supplier for cable tray

    To present the CAT5 and CT100 in node zero - looking to get hold of some steel cable tray - 150mm wide, with shallow sides (10-12mm) I will be using this flat to the wall rather than hung as normal...
  15. Replies
    6
    Views
    19,729

    Re: Phone line connections at Patch panel

    Think I have sorted it - some of folders are not viewable to public - try this:
    http://www.esnips.com//r/td/doc/1e18bca3-9acc-4a5b-8759-1ae659c249fe/Patch-Panel.jpg


    I have shown the set up I...
  16. Replies
    6
    Views
    19,729

    Re: Phone line connections at Patch panel

    Strange about the image .. if I click on it I see it, can you try the direct link - rather than TINY url

    I'll also try the img option.
    ...
  17. Replies
    6
    Views
    19,729

    Phone line connections at Patch panel

    I have wired out house to T586B, and just about finished all the faceplates.
    After advice here picked up a good deal on some 24 way 19" patch panels from eBAY. (Cat5e mint condition for £3.5 each)...
  18. Replies
    1
    Views
    1,927

    CAT5e patch panel choice

    Need to get hold of a few 16 way patch panels.

    First off thought I would use 16 way, to make cabling a bit easier than 24 way (assume nobody would disagree with that ?)

    Looking around I see...
  19. Replies
    1
    Views
    3,125

    Correct CT100 crimp size

    I bought a load of F-Type crimp plugs for CT100.
    I bought these from CPC, and asked them to specify the correct crimp tool .. and they supplied an H Tools HT-336G ratchet crimp.

    This has a Hex...
  20. Replies
    1
    Views
    9,694

    CAT5 .. T568A or T568B termination

    I have flood wired the house with CAT 5e, and now need to terminate all faceplates.

    I can use T568A or T568B .......... Googling & searching seems to bring up different answers.
    When we are...
  21. Replies
    5
    Views
    4,615

    Re: 19" rack supplier

    Thanks ... I'll request a catalogue
  22. Replies
    5
    Views
    4,615

    Re: 19" rack supplier

    Thanks
  23. Replies
    5
    Views
    4,615

    19" rack supplier

    I need to source a 19" rack, and want one with the inners that can swivel ... as I won't be able to get behind it ... I have seen some small cabs, with a glass front door (nor really necessary for...
  24. Replies
    1
    Views
    2,483

    Hooking up the phones

    I flood wired the house with CAT5e during the build.
    Have a mass of it in Node zero ... now need to hook up the incoming PSTN line to all the required sockets.
    How did you guys achieve this neatly...
  25. Replies
    2
    Views
    3,988

    Re: 2 x 1 way cct dilema

    Sounds like an ideal answer to me - thanks I'll give it a go.
Results 1 to 25 of 26
Page 1 of 2 1 2