  1. I don't have an T87RF but for those that do it...

    I don't have an T87RF but for those that do it could be simulated by resting the sensor above a hot radiator - should be easy to get the reading to 32 degrees or above that way. Anyone game to try to...
  2. Replies
    107
    Views
    12,393

    For the record I still get "comms errors" from...

    For the record I still get "comms errors" from the hot water sensor. Nothing I do will fix it. I have just learnt to live with it because I have better things to do with my time.

    From sniffing...
  3. I had no luck with the variable speed modes on my...

    I had no luck with the variable speed modes on my Alpha 2 - same as you, runs too slowly and the boiler overheats, so I run it in fixed speed 1 or 2.

    I think the variable speed modes have a...
  4. Replies
    1
    Views
    270

    It wont be a potentiometer as you can turn it...

    It wont be a potentiometer as you can turn it infinitely in either direction.

    From memory it's an infrared optical chopper system - very commonly used in digital knobs which can turn infinitely.
  5. Replies
    7
    Views
    705

    Manually overriding zones on an HR92 when the...

    Manually overriding zones on an HR92 when the heating is in away/heating off mode will not work in the latest firmware version. Neither of these modes will recognise manual overrides, and if the room...
  6. Replies
    7
    Views
    705

    No you're not missing anything unfortunately. ...

    No you're not missing anything unfortunately.

    The custom action applies one custom schedule to one or more selected zones, but the unselected zones will continue to follow their normal schedules....
  7. Replies
    10
    Views
    741

    I really don't see the attraction of using NiMH...

    I really don't see the attraction of using NiMH in the HR92. The only real benefit is from a waste reduction perspective, in every other way they're vastly inferior in this application.

    Aside from...
  8. Replies
    10
    Views
    741

    I've been using GP Ultra or Varta Alkaline's in...

    I've been using GP Ultra or Varta Alkaline's in mine for over 5 years - never had any leak or even show any signs of leaking.
  9. Anyone using Shelly EM for electricity monitoring?

    Like a number of us I was a user of Loop for gas and electricity monitoring before they decided to shutdown the service for the legacy monitors.

    I did take them up on the new electricity monitor...
  10. Replies
    12
    Views
    758

    Sounds like a plan. Before I had Evohome my...

    Sounds like a plan. Before I had Evohome my bypass radiator was the hall way so I had to add a TRV valve body to that one to get HR92's on all radiators, and also added an automatic bypass valve.
    ...
  11. Replies
    12
    Views
    758

    Why are you still using the old room stat to...

    Why are you still using the old room stat to control the boiler instead of Evohome?

    Evohome's algorithms are designed to control heat output of radiators by controlling both the individual water...
  12. Replies
    12
    Views
    758

    Indeed. If load scaling is on "Normal" try...

    Indeed. If load scaling is on "Normal" try changing it to "Partial", or even off.
  13. "Usual practice" perhaps, but that assumes you...

    "Usual practice" perhaps, but that assumes you are trying to adjust the balancing of the radiators to produce a certain temperature differential across each radiator. This is indeed the traditional...
  14. Yes this is exactly what happened to me when I...

    Yes this is exactly what happened to me when I tried to use the variable speed modes on my pump - all three variable modes were completely useless on my system because the pump would slow right down...
  15. Your point about reflective metallic surfaces is...

    Your point about reflective metallic surfaces is correct, however most modern radiators are painted and therefore don't have reflective metallic surfaces... Paint makes a good black body radiator and...
  16. You're right - depending on the orientation of...

    You're right - depending on the orientation of the valve. An old unidirectional valve should always be fitted so that the flow follows the direction of the arrow. This could be on the flow or return...
  17. Are there any long runs of pipe with no...

    Are there any long runs of pipe with no mechanical support, long enough to allow a resonance to occur? If so perhaps some additional support brackets would help.
  18. It's not that difficult but it is very time...

    It's not that difficult but it is very time consuming. But if you're willing to do it yourself it can be done over a couple of days in amongst other activities... I did my 9 radiator system in a day,...
  19. Sounds like the system just hasn't been balanced...

    Sounds like the system just hasn't been balanced properly, if at all. Regardless of the convoluted pipe run for those radiators, provided they heat up normally when they are the only radiators in use...
  20. Could be related to this: ...

    Could be related to this:

    https://www.automatedhome.co.uk/vbulletin/showthread.php?6419-Has-quot-Eco-quot-mode-been-broken

    Are you using the Eco button on the DTS92 by itself, or is system wide...
  21. Replies
    35
    Views
    2,050

    Yes, this is a known bug of the new firmware. I...

    Yes, this is a known bug of the new firmware. I noticed it and pointed it out to the Honeywell guys during the beta period in this post:
    ...
  22. Replies
    1
    Views
    416

    Lots of discussion threads on here about this to...

    Lots of discussion threads on here about this to read through if you have a browse...

    But in summary, the sensor in the HR92 will always read a bit higher than the room temperature (by 1-2C is...
  23. Don't use non-rechargeable batteries (Alkaline or...

    Don't use non-rechargeable batteries (Alkaline or Lithium) in the Evotouch. Definitely not when it is on the mount as it will try to charge them, and even if you took them out before putting them on...
  24. Replies
    20
    Views
    2,801

    Only 1.5C error? Try 4-5 degrees for me. :) (At...

    Only 1.5C error? Try 4-5 degrees for me. :) (At times when the temperature is rapidly increasing or decreasing - eg morning and evening with clear skies)
  25. Can't speak for the HCF82 but the HR92 doesn't...

    Can't speak for the HCF82 but the HR92 doesn't use a discrete bead of any sort, it uses a temperature measurement chip with a built in sensor.