  1. Replies
    20
    Views
    1,291

    Only 1.5C error? Try 4-5 degrees for me. :) (At...

    Only 1.5C error? Try 4-5 degrees for me. :) (At times when the temperature is rapidly increasing or decreasing - eg morning and evening with clear skies)
  2. Can't speak for the HCF82 but the HR92 doesn't...

    Can't speak for the HCF82 but the HR92 doesn't use a discrete bead of any sort, it uses a temperature measurement chip with a built in sensor.
  3. I'm not sure what you're planning to do with it...

    I'm not sure what you're planning to do with it as a "floor sensor" - do you mean a sensor to measure the water temperature of wet underfloor heating or element temperature of electric under floor...
  4. Replies
    5
    Views
    819

    Welcome to the world of antiquated RF protocols...

    Welcome to the world of antiquated RF protocols which don't use acknowledgements to confirm that the target device actually received a message... ;)

    In short, the BDR91 continuing to cycle on for...
  5. Replies
    6
    Views
    711

    After 5 years of using Evohome I have my first 62...

    After 5 years of using Evohome I have my first 62 degree phantom zone in the iPhone app... :P

    I haven't touched a thing either - it's just appeared for no apparent reason. Haven't got around to...
  6. Replies
    24
    Views
    3,497

    Looks good but also looks like a lot of work! ...

    Looks good but also looks like a lot of work!

    Lets hope you don't need to do a warranty claim on that HR92 - I think the reseller would not be amused... :D
  7. Replies
    9
    Views
    1,629

    Probably lost in translation... :D

    Probably lost in translation... :D
  8. I've had a few failed zone change warnings myself...

    I've had a few failed zone change warnings myself recently via the Alexa integration.

    I have an Alexa Goodnight routine which turns off various lights and performs individual zone overrides for...
  9. 66% is definitely the HR92 trying to call for...

    66% is definitely the HR92 trying to call for heat.

    Unfortunately the battery contacts are a weak point in the HR92 design - I've had to tighten the contacts on all of mine at some point, some...
  10. Lots of points buried in there so I have a few...

    Lots of points buried in there so I have a few questions:

    I assume you have the HR92 set to display measured temperature rather than the set point?

    How are you determining the valve hasn't...
  11. We have two one year old radiators in the dining...

    We have two one year old radiators in the dining room that I installed when the room was renovated, a 4 year old radiator in the bathroom that I installed (which is already going rusty at the bottom...
  12. The thread is moot now anyway. The guy came out...

    The thread is moot now anyway. The guy came out to do the site survey and asked a few basic questions and quickly discovered that were weren't in fact eligible for the grant and was on his way. Seems...
  13. "solution for the variable target flows"? I hope...

    "solution for the variable target flows"? I hope you don't mean by using an OpenTherm monitor?
  14. If your boiler is leaving rooms at 3 degrees...

    If your boiler is leaving rooms at 3 degrees below their set points with a 40% TPI duty cycle then I'm pretty sure that your boiler is struggling to put out enough heat for the number of radiators...
  15. That reminds me, I really must look at home...

    That reminds me, I really must look at home assistant...
  16. Thanks for the recommendations for Intergas. Not...

    Thanks for the recommendations for Intergas. Not sure if that will be an option with grant funding or whether it will be a "here's what we're offering" situation. Will find out on Friday!

    We have...
  17. Evohome-munin...

    Evohome-munin is a python plugin for the monitoring/graphing software Munin.

    Although I didn't write it originally I've been defacto maintaining it for the last couple of years by submitting PR's...
  18. Evohome and OpenTherm boiler recommendations?

    Hi All,

    I know the information on which boilers do and don't play well with Evohome OpenTherm is buried in this forum somewhere, and I've read quite a bit of it in the past (and forgotten more...
  19. Replies
    5
    Views
    838

    Sounds like you had a faulty unit.

    Sounds like you had a faulty unit.
  20. The best thing to do is buy high quality SD cards...

    The best thing to do is buy high quality SD cards and of reasonable size if you want reliability and longevity. The write endurance difference between an el-cheapo and a good name brand like Samsung...
  21. I thought this thread wasn't for digs... ;)

    I thought this thread wasn't for digs... ;)
  22. Optimal start only makes an adjustment of about...

    Optimal start only makes an adjustment of about 15 minutes per day for the start time.

    So if you get a sudden weather swing from cold to hot and the actual needed warm up time of the room is now...
  23. Replies
    31
    Views
    3,599

    That's about what I'd expect. The reminder beep...

    That's about what I'd expect. The reminder beep starts quite soon, but it should run for 2-3 hours before the big red warning that blocks the screen appears. If you leave it you'd probably find you...
  24. A flashing red light on the BDR91 means it is...

    A flashing red light on the BDR91 means it is either not bound or has lost comms with the Controller.

    I would fix this first before worrying about reliability of the CS92A, clear the bindings on...
  25. Yes, the CS92A sends its updates too rarely (1...

    Yes, the CS92A sends its updates too rarely (1 hour between updates if no changes have occurred) and does not send every message twice like the DTS92 does. It doesn't take many lost messages before...