    I get over 2 years quite easily. And these are...

    I get over 2 years quite easily. And these are with regular Costco alkaline batteries. Nothing fancy.
  2. I don't think what you are wanting to do is...

    I don't think what you are wanting to do is possible.
  3. That is the same way it has always been on all...

    That is the same way it has always been on all versions of the Evohome.
  4. Did you sort this?

    Did you sort this?
  5. I don't like the flip screen of the HR92 at all,...

    I don't like the flip screen of the HR92 at all, but I do like the features it has. My house is all HR80 and I see absolutely no reason to change. So unless you NEED access to the settings the HR92...
  6. We have a similar set up. A multi radiator zone...

    We have a similar set up. A multi radiator zone but I've split that into 2 and the one near the TV Couch has its own schedule, to keep us warmer there for longer.
  7. Come to think of it, I have seen this bug in an...

    Come to think of it, I have seen this bug in an HR80 too.
  8. The Evohome can work as a single zone room stat...

    The Evohome can work as a single zone room stat with a single boiler relay, in fact that is how is arrives when bought new I.e. It can be a direct replacement for a Y87RF and a BDR91, this is why is...
  9. I have exactly the same setup during the day. ...

    I have exactly the same setup during the day.

    I have a 38Kw boiler (please don't ask why!) but then as I started making changes, my heating requirements kept going down not up. I now have my...
  10. What you are experiencing is not unusual but I...

    What you are experiencing is not unusual but I agrees super frustrating. It's all to do with stupid TPI and it not being synced. Also the boiler is cycling to the total system demand and the UFH is...
  11. Yes Resideo do fix bugs, but in their time, not...

    Yes Resideo do fix bugs, but in their time, not yours
  12. The summary page is showing the Zone's Heat...

    The summary page is showing the Zone's Heat Demand and the System's Heat Demand. Only the HR92 is capable of showing the valve position. And Simon produced an interesting analysis of how those two...
  13. The System Summary page shows you the aggregated...

    The System Summary page shows you the aggregated (or typically highest) Heat demand for a zone. And then the top line is against aggregating all Zone into a single boiler relay Heat Demand.
    Valve...
  14. When you open up the HR valve, have you checked...

    When you open up the HR valve, have you checked the System Summary page to see if that zone's Heat Demand has actually changed or not?
  15. You are relying on the contact sensor of the...

    You are relying on the contact sensor of the heating kit to have absorbed the heat into it's metal head. So any heat then escaping from the hole behind it is insignificant, in terms of the...
  16. If you had a single Evohome controller using its...

    If you had a single Evohome controller using its internal sensor controlling a single BDR91, positioned in the same location as the Y87RF - the two of them should have behaved exactly alike. Or are...
  17. I lot of people don't realise how many variables...

    I lot of people don't realise how many variables there are when dealing with a single heat source, multi zone system. That's why I said comparing Evohome to a single zone room thermostat is not a...
  18. I think I have proven this is a bug and might...

    I think I have proven this is a bug and might actually have been there for a very long time, except now it has surfaced because of there being no need to change the Device type. What seems to happen...
  19. What else was Evohome controlling that was...

    What else was Evohome controlling that was causing the overshoots? I bet if you put the Evohome controller as your room sensor in the same place as the Y87RF and used it to control a single BDR91...
  20. Replies
    80
    Views
    40,162

    What's the point of having better range on the...

    What's the point of having better range on the room sensor while using the HR92 actuator with a poor signal?
  21. Replies
    12
    Views
    15,827

    From my experience of these "man in middle"...

    From my experience of these "man in middle" devices (I too use a VR33 on my Vaillant) is that you are completely dependent on the OT translation implementation within that device.
    e.g. I have...
  22. Replies
    10
    Views
    839

    Interesting, I wonder what the differences are...

    Interesting, I wonder what the differences are between the 20A and 10A.
  23. I moved from a BDR91 controlling my UFH to a HM80...

    I moved from a BDR91 controlling my UFH to a HM80 which is actually better suited for the purpose.

    But there is a software hack that I have tested that works pretty well when you use the BDR91...
  24. Replies
    80
    Views
    40,162

    It was never actually produced by Honeywell,...

    It was never actually produced by Honeywell, rather more for Honeywell via a jv. The company has now branched into its own called https://www.airios.eu/
  25. Replies
    16
    Views
    1,210

    Sorry, I should have been clearer how is your...

    Sorry, I should have been clearer how is your Domoticz getting the Evohome data. Seems to me, you don't have an RF interface that is feeding the Evohome data into Domoticz. You need something like...