  1. I would clear all binding on the DHW BDR91, and...

    I would clear all binding on the DHW BDR91, and bind it again. It may be double bound.

    Press and hold the button for 15 seconds (until the red LED blinks rapidly) to clear any previous binding...
  2. Simply change Appliance Control to OpenTherm, you...

    Simply change Appliance Control to OpenTherm, you definitely don’t need to touch your HR92s and probably don’t need to touch your stored hot water CS92/BDR91 setup either, but simple to do if needed...
  3. 1. Yes 2. CS92 sensor and high-limit thermostat...

    1. Yes
    2. CS92 sensor and high-limit thermostat controlling DHW valve
    3. NO 2-port that closes when DHW NC 2-port opens. I also stop the UFH pump on DHW heating via a separate BDR91. For additional...
  4. Install GSHP before RHI payments stop? Evohome GSHP control

    Just had 1,200m2 of farmland returned to me. My daughter is tennis mad and would like a tennis court constructed.

    I figure it makes sense to prepare for the future and install a Ground Source...
  5. I see this same behaviour with my setup OpenTherm...

    I see this same behaviour with my setup OpenTherm + 4xHCE80.

    Nothing you can do about it I’m afraid. At low zone demands < 10% (24C) I observe the HCE80s TPI the UFH pump even though the boiler...
  6. Thread: X-Plan

    by kevinsmart
    Replies
    11
    Views
    1,130

    Ideally Evohome would allow you to set different...

    Ideally Evohome would allow you to set different max CH and DHW OpenTherm temperatures, but unfortunately it doesn’t. And with some boilers the default 80C or 90C is too high.
  7. Thread: X-Plan

    by kevinsmart
    Replies
    11
    Views
    1,130

    Sure, if you are happy with the same max flow...

    Sure, if you are happy with the same max flow temperature and boiler settings for both DHW and CH.

    In my weather compensation setup, I disconnect the outside temperature sensor on DHW heating,...
  8. Replies
    6
    Views
    974

    There is a nice description by DBMandrake here: ...

    There is a nice description by DBMandrake here:

    https://www.automatedhome.co.uk/vbulletin/showthread.php?6134-Evohome-firmware-02-00-19-31-Beta-Trial-Exclusive-for-Automated-Home-Members/page63
  9. Thread: X-Plan

    by kevinsmart
    Replies
    11
    Views
    1,130

    Evohome support of DHW priority has only just...

    Evohome support of DHW priority has only just been added to its firmware. Previously if you had CH and DHW valves you would wire them to the DHW BDR91 such CH closes when DHW opens.

    I’m not sure...
  10. Thread: X-Plan

    by kevinsmart
    Replies
    11
    Views
    1,130

    Because default operation is OpenTherm heating...

    Because default operation is OpenTherm heating with only HR91/2s controlling flow to radiators.

    When there is a demand to heat the DHW cylinder you don’t want 70C flow in your CH circuit leading...
  11. Thread: X-Plan

    by kevinsmart
    Replies
    11
    Views
    1,130

    Basically the CH 2-port is Normally Open and the...

    Basically the CH 2-port is Normally Open and the DHW valve Normally Closed.

    When there is a Priority DHW demand the CH valve is closed and DHW opens, so all flow is to the cylinder.

    With...
  12. Thread: X-Plan

    by kevinsmart
    Replies
    11
    Views
    1,130

    https://www.intergasheating.co.uk/app/uploads/2019...

    https://www.intergasheating.co.uk/app/uploads/2019/11/X-Plan-diagram-Rapid-HRE-Eco-RF-low-voltage-option-V1.pdf
    ...
  13. As I understand it, this parameter sets the...

    As I understand it, this parameter sets the closed to open, 0-100% (90 degrees) actuator time.

    What do you observe when there is a 100% demand, how long does it take to open the valve?
  14. Yes, looks like a bug, but does the default 150s...

    Yes, looks like a bug, but does the default 150s not work for you, why do you want to change it?
  15. Thinking back to how I set my HM80 up, Bruce. It...

    Thinking back to how I set my HM80 up, Bruce. It was on the older firmware and at that time after configuring the parameters, you needed to change the heating type from MIXING VALVE to ZONE VALVES,...
  16. Replies
    7
    Views
    800

    If there is no heating demand 0% then the boiler...

    If there is no heating demand 0% then the boiler won’t fire and the radiator valves won’t open.

    Try setting zone(s) 2C above the current temperature reading to test whether they heat up.
  17. Replies
    7
    Views
    800

    What zone heating demands do you see in the...

    What zone heating demands do you see in the Installer menu (long press Settings)?
  18. Replies
    69
    Views
    12,443

    Not now, I moved house and predominantly have...

    Not now, I moved house and predominantly have HCE80s now. It was working fine with the latest firmware as far as I recall but I was just using the default run time setting, I only changed the max...
  19. 1 is L red 2 is N blue 3 is switched L to...

    1 is L red
    2 is N blue
    3 is switched L to boiler yellow

    BDR91:
    Connect L and N
    Bridge L to A
    B to boiler yellow
  20. Fit boiler control, it will be inefficient...

    Fit boiler control, it will be inefficient otherwise, with the boiler cycling when TRVs are closed.
  21. It is a supported configuration for large rooms. ...

    It is a supported configuration for large rooms.

    I edited my post above with instructions on how to do it.
  22. I encountered this situation. All you need to do...

    I encountered this situation. All you need to do is to use two zones on the HCC80, one with 3 actuators, the next with 2 and bind them to the same room zone/thermostat in Evohome. They will...
  23. Replies
    6
    Views
    695

    I found BDR91 relays to be noisy, and with TPI...

    I found BDR91 relays to be noisy, and with TPI annoying if installed in a living area.

    The HCE80 has more intelligence around pump control, with overrun, and quiet actuator control (solid...
  24. Replies
    69
    Views
    12,443

    You should see better zone temperature control...

    You should see better zone temperature control with the HM80, if that was previously a problem for you?
  25. 1837183818391840 Individual zone demands are...

    1837183818391840

    Individual zone demands are between 0 to 100% with the maximum demand sent to the OpenTherm bridge.