  1. Replies
    21
    Views
    2,456

    We have proven that a low battery causes the...

    We have proven that a low battery causes the offending device to send out garbled messages that overwhelms the radio channel. This then causes a knock on impact on all the comms across the system. In...
  2. Replies
    21
    Views
    2,456

    The HRxx has no static memory of setpoints or...

    The HRxx has no static memory of setpoints or schedules. It relies on the controller telling it what to do. So when you power it up, it defaults to 20C until the next sync cycle when the controller...
  3. @filbert doesn't your boiler have some installer...

    @filbert doesn't your boiler have some installer or diagnostic menu that allows you to see Return temperature. It's quote a key data point for the boiler. So it must be there somewhere.
  4. There is very little two way comms between the...

    There is very little two way comms between the OTB and the controller. And that's a shame.
    Also I am not surprised that some values returned by the OTB are either static or plain wrong. It all...
  5. Replies
    9
    Views
    1,762

    The boiler's pump will almost certainly be...

    The boiler's pump will almost certainly be running anyway because that will have an over run on it. But an UFH pump will normally just pump round the manifold, as long as the manifold outlets are...
  6. Replies
    13
    Views
    1,717

    Evohome will use a 90C flow temp on 100% heat...

    Evohome will use a 90C flow temp on 100% heat demand, whether that demand is from HW or CH. Hence why I say it doesn't differentiate between HW and CH. HW will only ever go from 0% to 100% heat...
  7. Replies
    9
    Views
    1,762

    With UFH, what you want is that the UFH pump...

    With UFH, what you want is that the UFH pump stays on for as long as possible during the entire heating schedule. But what a BDR91 will try and do is keep turning on and off several times an hour....
  8. Replies
    9
    Views
    1,762

    My UFH has its own motorised zone valve. So the...

    My UFH has its own motorised zone valve. So the BDR91 was connected to the zone valve. The microswitch inside the zone valve would power the pump. This was to ensure the pump would only run after the...
  9. Replies
    9
    Views
    1,762

    Now get ready to get frustrated with the BDR91...

    Now get ready to get frustrated with the BDR91 and its inbuilt TPI. It will keep switching the UFH pump on and off several times an hour, which is quite undesirable for an UFH system. What you might...
  10. Replies
    13
    Views
    1,717

    My guess is based on the Vaillant but it will be...

    My guess is based on the Vaillant but it will be similar. The Intergas Cylinder NTC will tell the boiler what the temperature of the water in the Cylinder is. There must be some HW settings on the...
  11. Replies
    13
    Views
    1,717

    Nope,another missed opportunity, even though the...

    Nope,another missed opportunity, even though the OTB is able to distinguish between CH and HW workloads, it doesn't do much with it. Except when heating HW it goes from 10C to 90C demand only....
  12. Replies
    13
    Views
    1,717

    I absolutely hate that TPI is built into the...

    I absolutely hate that TPI is built into the firmware of the BDR91. It should have been overrideable. Worse still the relay settings available in the Controller then go and apply to all Relays in the...
  13. Replies
    13
    Views
    1,717

    Not that I can think of, the software now just...

    Not that I can think of, the software now just gives existing installations the option. What we fought for though was the forced DHWP setting that couldn't be turned off. Thank goodness Resideo...
  14. Replies
    13
    Views
    1,717

    The Evohome now allows you to implement DHWP...

    The Evohome now allows you to implement DHWP regardless of the way the system is piped.
    You could always implement DHWP with an X plan with a single relay and using a Normally Open Valve.
  15. Being the guy who coded all this into Domoticz, I...

    Being the guy who coded all this into Domoticz, I have some bad news. Evohome uses none of this information! Infact in the latest firmware, it didn't even query for this information from the OTB. I...
  16. Replies
    13
    Views
    1,717

    In order to use HW priority, you will need BDR91...

    In order to use HW priority, you will need BDR91 controlling the HW and CH loops, in addition to your OTB that fires the boiler.
  17. Replies
    18
    Views
    1,975

    The data in the Fault Logbook device will tell...

    The data in the Fault Logbook device will tell you what the actual fault is.
    see https://www.automatedhome.co.uk/vbulletin/showthread.php?6471-Domoticz-notifications&p=46103&viewfull=1#post46103...
  18. Yes I am already on the post 2025 set up i.e....

    Yes I am already on the post 2025 set up i.e. Single FTTP that does both Broadband and landline. No copper any more. And that allowed me to finally say bye bye Virgin. I was forced to use them...
  19. With Vodafone the landline is free. Doesn't cost...

    With Vodafone the landline is free. Doesn't cost us anything and we've had the same number forever. We keep our mobile phones downstairs overnight, so in a real emergency the landline is what will be...
  20. I have always used my own routers. But now with...

    I have always used my own routers. But now with FTTP, the phone line is VOIP and Vodaphone won't give out the VOIP details. So currently am stuck with using the Vodafone router, as without it we...
  21. I had to use terminal 7-8-9 in order to get my...

    I had to use terminal 7-8-9 in order to get my OTB to fire the boiler. And because that is undocumented, until I figured it out, I had to use the 240V trigger to fire the boiler and my VR33/OTB were...
  22. I'm guessing this interface can only monitor the...

    I'm guessing this interface can only monitor the OT traffic, it cannot actually inject or alter a command? That would require a gateway?
  23. Replies
    3
    Views
    500

    Or just delete the location and repair the...

    Or just delete the location and repair the installation to the app.
  24. Care to share your circuit and code?

    Care to share your circuit and code?
  25. Replies
    27
    Views
    2,606

    What is the HW Over run set to? Also when you saw...

    What is the HW Over run set to? Also when you saw the HW temp go beyond the set point, what was the actual Heat Demand for the HW in the settings menu