Search:

Type: Posts; User: gordonb3

Page 1 of 10 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    9
    Views
    1,298

    If your computer is broken you call for a...

    If your computer is broken you call for a hardware engineer, not a Microsoft Certified professional. And even if you did manage to find a Microsoft guy that actually understands computers you still...
  2. Replies
    9
    Views
    1,298

    Pushing the button on the BDR unit will instantly...

    Pushing the button on the BDR unit will instantly turn the kettle on. Of course if no zone is requesting it will shut off again after a few minutes. As for opening all radiators, taking off the TRV...
  3. There is no array element in the response, so I'm...

    There is no array element in the response, so I'm pretty sure this call only supports returning a single address



    Correct. As you probably found the return from the API is crippled and starts...
  4. Replies
    7
    Views
    587

    It was on/off all day and even when I was able to...

    It was on/off all day and even when I was able to receive readings on various times I was only able to connect to the EMEA API (0.5 degree resolution). I doubt if it would have accepted any commands.
  5. Replies
    15
    Views
    1,571

    Does this route through Domoticz? There was a...

    Does this route through Domoticz? There was a change to the Evohome code on Jan 30 (see: https://github.com/domoticz/domoticz/pull/4634 ) but I don't think it should affect zone name querying.
  6. Replies
    5
    Views
    858

    That would be highly unlikely as the Evohome...

    That would be highly unlikely as the Evohome components communicate over 868MHz and even a Zigbee source is spitting out harmonics these should not hit the BDR91. It is very possible however that you...
  7. While the BDR can hold up to four binds, double...

    While the BDR can hold up to four binds, double binding sounds like a source for error as one (the `zone`) is supposed to control the other (boiler). I wouldn't even try it. I'm not really aware of...
  8. Nice of them to give ahead warning this time,...

    Nice of them to give ahead warning this time, even if only on a channel where no person in their right mind should want to be on. Either way, at 07:39 GMT still no miscommunications logged and it...
  9. Sort of, yes. Your input needs to be sent to the...

    Sort of, yes. Your input needs to be sent to the HR92 which then in order needs to instruct the BDR91. The delay comes from the fact that the HR92 is not awake all the time but is only available for...
  10. Honeywell refers to this as the `base plate`. Two...

    Honeywell refers to this as the `base plate`. Two versions exist, the standard 30mm that comes with the unit and a replacement 28mm version (ACH28). It must be noted here that I've never seen the...
  11. The controller does contain a thermostat, as far...

    The controller does contain a thermostat, as far as I know it won't serve as a zone actuator though. The concept is a bit fuzzy, but the controller is more like a smart remote to the HR91/92 units...
  12. Correct. Might have been somewhat clearer: left...

    Correct. Might have been somewhat clearer: left column are the connectors inside the BDR91, right column the connectors from your junction box.

    I suggest you leave the wiring in place though, just...
  13. Quick search for an installation manual gave me...

    Quick search for an installation manual gave me the following link: http://www.free-instruction-manuals.com/pdf/p4734564.pdf

    Seems like your setup is best described by #4e. Installing the BDR91 is...
  14. Is it a wired thermostat? There appear to be...

    Is it a wired thermostat? There appear to be multiple wiring configurations, so you should check the wiring first. Simplest version involves a 2-strand telephone wire towards your boiler and if that...
  15. Replies
    12
    Views
    1,691

    Maybe worth noting that the tips given depend on...

    Maybe worth noting that the tips given depend on the controller type and software version, e.g. the controller I have does not have a `System Summary` menu entry and Eco is fixed to 3 degrees below...
  16. Thread: App failure

    by gordonb3
    Replies
    11
    Views
    873

    Server was down from 10:18 CET. At 13:09 I...

    Server was down from 10:18 CET. At 13:09 I received the first sign of life and was able to establish a session at 13:17 and retrieve data. This lasted until 13:22 and then it started returning errors...
  17. Replies
    19
    Views
    1,965

    I suppose this will mostly depend on how much...

    I suppose this will mostly depend on how much heat the boiler can generate. In my case I am on city heating and that is practically unlimited heat supply. In the cold season I heat the children's...
  18. Replies
    11
    Views
    1,856

    I'm somewhat puzzled by the purpose of this...

    I'm somewhat puzzled by the purpose of this function. Is this for homes that have no insulation whatsoever?
  19. Replies
    14
    Views
    1,380

    Well, according to you it isn't and according to...

    Well, according to you it isn't and according to me it wouldn't. Seems to me we are pretty close to full agreement.
  20. Replies
    14
    Views
    1,380

    Apparently I am very bad at explaining. The...

    Apparently I am very bad at explaining.

    The Round wireless is a zone controller and as such it will signal the valve unit whenever it reaches one of its trigger points. Instantly.

    The Evohome...
  21. Replies
    14
    Views
    1,380

    Well, allow me to explain to you then why I think...

    Well, allow me to explain to you then why I think the advice was wrong.

    Evohome is designed as a multi zone system where every individual zone must be able to generate a heat request to your heat...
  22. Replies
    14
    Views
    1,380

    Not real sure how you ended up with Evohome to...

    Not real sure how you ended up with Evohome to control a single zone and in fact without a valve for that zone. Evohome isn't designed for this and it is not surprising to see overshoots as well as...
  23. Replies
    18
    Views
    1,632

    Seems like the two of you are not communicating...

    Seems like the two of you are not communicating on the same level.

    The question Bruce asked meant to be what hardware type you selected in Domoticz to make it show your Evohome zones and...
  24. Replies
    18
    Views
    1,632

    Likely better to ask what hardware type is used....

    Likely better to ask what hardware type is used. A source scan reveals that "Fault Logbook" is part of EvohomeRadio, so you won't see this device on Web or Script.
  25. Replies
    13
    Views
    2,651

    True. That said, before I had Evohome I used...

    True.

    That said, before I had Evohome I used to set the living room at 24C just to create the trigger for the heating to come on and allow the radiators upstairs to get hot. If the UFH in the...
Results 1 to 25 of 228
Page 1 of 10 1 2 3 4