  1. Wasn't that a coming later feature, rather than a...

    Wasn't that a coming later feature, rather than a current beta one.
  2. A variable Economy quick action set back, please....

    A variable Economy quick action set back, please. It's such an under utilized feature because of the fairly useless fixed 3C. Hometronic used to allow it be changed.
  3. That and the ability to bind your own external...

    That and the ability to bind your own external temperature sensor. However, that was never possible on the WiFi version. I do think the arguments to remove it at the Zone level are poor. But may be...
  4. Is zone level optimisation coming back? Or is...

    Is zone level optimisation coming back? Or is that still an All or Nothing?
  5. Replies
    1
    Views
    88

    Surely by now, once you install it the servers...

    Surely by now, once you install it the servers will force an update down shortly. Otherwise a simple call with the helpdesk will resolve that for you.
  6. ALL radiators should ideally have TRVs and then...

    ALL radiators should ideally have TRVs and then the Evohome radiator controllers. The full benefit of Evohome is when every heat output can be controlled by the controller.
  7. The programmer will go and be replaced by the...

    The programmer will go and be replaced by the BDR91. As for the DHW sensor, if you have a sealed unvented cylinder you will need to use the insertion sensor.
  8. Replies
    37
    Views
    1,033

    I too was going to say that but I am not...

    I too was going to say that but I am not qualified. in my case my plumber made the assessment that even a system boiler would not be ideal, so suggested a Heat Only sealed system with a Sealed DHW...
  9. Replies
    37
    Views
    1,033

    @G4RHL, I think you might be confusing the heat...

    @G4RHL, I think you might be confusing the heat output needed from a Combi versus a Heat only stored HW.
  10. Replies
    37
    Views
    1,033

    All I can say is, 38Kw was correctly sized if I...

    All I can say is, 38Kw was correctly sized if I had a traditional radiator only system. But like I said, the conversions from radiators to UFH and the zoning possible with Evohome has meant that a...
  11. Replies
    37
    Views
    1,033

    Yes it was definitely oversized when it went in...

    Yes it was definitely oversized when it went in and contrary to old school thinking even though the house has been extended a lot since the boiler was installed, the heating requirements have...
  12. Replies
    37
    Views
    1,033

    Sorry a Vaillant 438 is a 38Kw boiler, so pretty...

    Sorry a Vaillant 438 is a 38Kw boiler, so pretty close to your 36Kw one.
  13. Replies
    37
    Views
    1,033

    I have a heat only 438Kw and when it was running...

    I have a heat only 438Kw and when it was running at full pelt it not only needed a new 28 from the gas meter to the boiler, it even needed the gas board to bring in a new main from the street to the...
  14. Replies
    37
    Views
    1,033

    The old imperial sizes are still available but...

    The old imperial sizes are still available but not from the leading brands. And it shows in the quality. I replaced an old imperial with a new one and then finally had to bite the bullet and change...
  15. Replies
    37
    Views
    1,033

    try and see if you can achieve the 20C drop...

    try and see if you can achieve the 20C drop between flow and return on each radiator. that give you the maximum efficiency.
  16. from another thread. Try setting the Tmax on...

    from another thread.

    Try setting the Tmax on the boiler BEFORE attaching the Opentherm bridge. I have seen this work in most cases.
  17. Replies
    37
    Views
    1,033

    Sorry, it's been one of those days.

    Sorry, it's been one of those days.
  18. Replies
    40
    Views
    4,618

    This could be huge.

    This could be huge.
  19. Replies
    37
    Views
    1,033

    Maybe there is some sort of a hierarchy like in...

    Maybe there is some sort of a hierarchy like in the ebus.
  20. Replies
    37
    Views
    1,033

    I think that probably only applies to Viessmann.

    I think that probably only applies to Viessmann.
  21. Replies
    40
    Views
    4,618

    Choose a boiler that has been currently confirmed...

    Choose a boiler that has been currently confirmed to work correctly with the OTB, rather than hedging your bet on better future support. Only a small minority aren't and even for them, adding an OTGW...
  22. Replies
    40
    Views
    4,618

    Unless the OTB is intelligent enough to simply...

    Unless the OTB is intelligent enough to simply respond and relay a new OT command to the boiler, I cannot see how a new Controller firmware will fix this for the handful of boilers that need this...
  23. Replies
    2
    Views
    220

    This has happened to me once on a HR80 where it...

    This has happened to me once on a HR80 where it wouldn't take on setpoints. Had to reset the HR80, clear the binding and pair it back on.
  24. Replies
    40
    Views
    4,618

    Isn't the world flat any way?

    Isn't the world flat any way?
  25. Replies
    2
    Views
    297

    Poll: Honeywell learns the heat characteristics of your...

    Honeywell learns the heat characteristics of your room, which is more useful that Nest learning when you are home! You can get Nest like functionality on Honeywell too using services like IFTTT
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4