  1. Replies
    20
    Views
    859

    Funnily enough I had mine set on 10 and found it...

    Funnily enough I had mine set on 10 and found it didn't update quick enough when drawing off. However changing to 7oc with a 2 min overrun seemed to be a sweet spot. Does it update more regularly...
  2. Replies
    20
    Views
    859

    Out of interest, what's you differential setting...

    Out of interest, what's you differential setting on?
  3. Replies
    25
    Views
    615

    No matter what you'll still have the same issue -...

    No matter what you'll still have the same issue - a Green IQ Vaillant will modulate 1:10, but that still will only modulate to 3.5kw Which is more than just one rad running at once.

    Have you...
  4. Replies
    25
    Views
    615

    The place i'd start is open all your lockshields...

    The place i'd start is open all your lockshields full. Put pump into 100% mode and close the bypass some so it's 3/4 closed. Set flow temp at 70oc. Run the system from cold and see if all the rads...
  5. Replies
    25
    Views
    615

    Put it in 100%, and close the bypass some more....

    Put it in 100%, and close the bypass some more. Not all the way shut but just open enough - get your installer to do this for you. You can't as it means removing the front of the boiler and you can't...
  6. Replies
    25
    Views
    615

    The pump probably want's adjusting and the...

    The pump probably want's adjusting and the internal bypass adjusting too, have you got an external bypass?

    How quick does the anti cycle kick in when the Partial Load is set to Auto? Anti Cycling...
  7. Replies
    25
    Views
    615

    Does it do S.53? How old is the boiler; there's...

    Does it do S.53? How old is the boiler; there's probably another issue at play rather than the Output being too large. It's a 38kw boiler but it'll do only 30kw on heating, within that it'll modulate...
  8. Replies
    20
    Views
    859

    The solution to your overshooting would be to...

    The solution to your overshooting would be to wire your Cylinder Stat back in series with the BDR91 and set it at 60oc.

    Has replacing the batteries resolved your issue? As you've said the battery...
  9. The HR91s will compensate for the radiator so...

    The HR91s will compensate for the radiator so will show less.

    The Main Panel is over due to the heat from the panel. I've had to offset mine -1.5oc because of this to get a true reading.

    My...
  10. Are your HR91s actually fitted to any radiators...

    Are your HR91s actually fitted to any radiators yet?
  11. Replies
    20
    Views
    859

    My own system I never have any issues with, other...

    My own system I never have any issues with, other than once when the batteries were low - as to be expected. Again others I have had no issues at all with.

    I have one customers who used to...
  12. Replies
    22
    Views
    1,241

    On another note, are they doing the Beta testers...

    On another note, are they doing the Beta testers like the last firmware update?

    As an Installer of these systems i'd love to be a part of this.
  13. Replies
    20
    Views
    859

    What cylinder do you have?

    What cylinder do you have?
  14. As others have said if it Ain't Broke don't fix...

    As others have said if it Ain't Broke don't fix it!

    I set and forget my Evohome and it works flawlessly! Even if it was unsupported I don't see why it would make me change if the system still...
  15. Replies
    22
    Views
    1,241

    Glad to hear that it's still Honeywells main...

    Glad to hear that it's still Honeywells main product for Connected Heating, with it being on the quiet front of late I was getting a bit worried it might get fully replaced by a new system due to the...
  16. Do you think there'll be a new Evo panel coming?

    So as other manufactures are catching up with Smart TRV heads and other things, Honeywell seem to be stuck at the moment with their current offerings on the 'Smart' side of things. There's just been...
  17. Replies
    20
    Views
    859

    Your discharge shouldn't really be dripping then,...

    Your discharge shouldn't really be dripping then, the Safety Valve will only blow off at 90oc and that's highly unlikely as one, your boiler would struggle to get to this and two, either the existing...
  18. Replies
    20
    Views
    859

    I've had a faulty one before now, swapped out and...

    I've had a faulty one before now, swapped out and seemed much better.

    Batteries have to be around 1.6v, soon as they start dropping south to 1.5v unit plays up.

    Make sure battery tensions are...
  19. Replies
    1
    Views
    202

    Yes a customer had them fitted.....4 out of 7 of...

    Yes a customer had them fitted.....4 out of 7 of them set on fire. He put water based CH back in after ripping his original system out....
  20. I have mine set at 3 cycles specifically for the...

    I have mine set at 3 cycles specifically for the reason so that boiler isn't cycling as much, and a minimum on time of at least 2 minutes. I have an older non condensing boiler and whilst it probably...
  21. Replies
    19
    Views
    1,600

    That's what I love about Evohome and many of my...

    That's what I love about Evohome and many of my customers do - you can just set it and forget it! The only time I ever really mess with the App if is the HW needs boosting or at this time of year...
  22. Replies
    19
    Views
    1,600

    I'd stick with your 22 year old boiler too!

    I'd stick with your 22 year old boiler too!
  23. Replies
    19
    Views
    1,600

    Not really no, as the boiler won't be able to...

    Not really no, as the boiler won't be able to modulate down enough to achieve that lower temperature and stay there. Of course this will happen if you've only got demand on a few radiators, if your...
  24. Replies
    19
    Views
    1,600

    Not really, Opentherm is a flow temperature set...

    Not really, Opentherm is a flow temperature set point. If your boiler only has a 1:4 modulation range, in some cases (on a 20kw output) itíll only modulate down to 5kw (or if 1:6, 3.3kw) if your...
  25. Replies
    19
    Views
    1,600

    Vaillant Green IQ, 1:10 modulation range. No...

    Vaillant Green IQ, 1:10 modulation range. No opentherm, but the modulation range makes it great for EvoHome. I'm told by some Vaillant Senior engineers it'll even modulate down more than the 1:10...