  1. @atm any thoughts on this load scaling behaviour?...

    @atm any thoughts on this load scaling behaviour? It's clearly not desirable.
  2. Pay attention, Bruce. "I switched off load...

    Pay attention, Bruce.
    "I switched off load scaling (from full)"
  3. Turning off load scaling immediately resolved the...

    Turning off load scaling immediately resolved the problem.
  4. I saw a similar problem last week. Lounge was...

    I saw a similar problem last week.
    Lounge was 1 degree below setpoint (boosted by 1 by cold wwather), no other zones wanted heat. Lounge wanted 100% BDR was 1% nothing happening.
    I switched...
  5. Documentation?

    Ally,

    I've lost track of what is actually in the new Beta and the controls we have available.
    Is there a document describing the latest UI and what the new functions (are supposed to) do?
    ...
  6. the zone is 'off' in that it is not calling for...

    the zone is 'off' in that it is not calling for heat because the room temp is above the setpoint which is still at 15.

    i don't believe the zone will have called for heat since the beta was...
  7. Andy, I don't understand why you are referring to...

    Andy, I don't understand why you are referring to CWB.

    the outside temperature is much higher than 15C.
    Other zones that have higher setpoints are being turned off because of WWS.

    My question...
  8. Bed 3: 06:00 15C, 09:30 15C, 17:30 15C, 22:30 15C...

    Bed 3: 06:00 15C, 09:30 15C, 17:30 15C, 22:30 15C
    Bed 4: 07:00 20C, 09:30 16C, 17:30 16C, 22:30 16C

    Bed 4 is behaving much as I expect it. I don't understand why Bed 3 isn't subject to WWS.
  9. I'm not expecting a CWB action for Bed 3. I was...

    I'm not expecting a CWB action for Bed 3. I was expecting WWS to set the offset to 5C like every other zone, including Bed 4 which had a setpoint of 16 at the time it got shut down.
  10. It's not in an override state. It's running on a...

    It's not in an override state. It's running on a schedule. The schedule has 4 intervals all currently set to the same temperature. So there are scheduled changes that effectively do nothing other...
  11. Same today. 9pm Outside temp 20C All rooms but...

    Same today.
    9pm
    Outside temp 20C
    All rooms but one off at 5C except one.
    Rooms were either at 5C overnight or switched to 5C about noon.

    Current room temp 22.9C, setpoint 15C
    This room has...
  12. All zones now OFF except that first one with the...

    All zones now OFF except that first one with the constant 15C setpoint. Current temp from HR92 is 21.4C

    Definitely not expected behaviour.
  13. I'm pretty sure it needs a setpoint change to...

    I'm pretty sure it needs a setpoint change to kick in. I have a bedroom that is currently set at 15C all day over several intervals. The room temp has been constantly above this (currently 19.9)...
  14. Andy, I think the setting of the zone setpoint...

    Andy,

    I think the setting of the zone setpoint to 5C when the zone gets turned off is going to confuse a lot of people.

    When you check the schedule it appears at first as if the setpoint is...
  15. Replies
    215
    Views
    62,829

    The data transmitted on the RF channel is...

    The data transmitted on the RF channel is effectively the output from a UART sending 8N1 data.
    The problem is all the devices in the system have slightly different clock rates and that means you...
  16. Replies
    215
    Views
    62,829

    That may actually be the first reference to...

    That may actually be the first reference to evofw3 on this thread
  17. Replies
    215
    Views
    62,829

    Make sure you pick a device that has a spare...

    Make sure you pick a device that has a spare hardware UART you can interface to the CC1101.
    There's potentially a much easier way to get the data from the radio
  18. Replies
    215
    Views
    62,829

    @smar. What firmware are you running. If my FIFO...

    @smar. What firmware are you running. If my FIFO branch do you have OT?
  19. Replies
    215
    Views
    62,829

    Do you have an OT module in your system? If so...

    Do you have an OT module in your system?

    If so are you seeing messages?
  20. Replies
    215
    Views
    62,829

    Which code are you running on the nano?

    Which code are you running on the nano?
  21. Replies
    13
    Views
    3,007

    Somewhat lucky there, it runs the length of the...

    Somewhat lucky there, it runs the length of the loft and then goes down the corner of a bedroom which is above a garage. Hid the run through that room by adding a very narrow stud+plasterboard to...
  22. Replies
    13
    Views
    3,007

    See my comment above My boiler is in the...

    See my comment above


    My boiler is in the loft on one side of the house. My UFH is on the ground floor on the other side. It' couldn't be further away


    That's irrelevant. The Controller...
  23. Replies
    13
    Views
    3,007

    For clarification the feed/return for the UFH in...

    For clarification the feed/return for the UFH in my system branches near the boiler close to the CH zone valve. It's not part of the rad loop.
  24. Replies
    10
    Views
    2,455

    I had a phantom zone I deleted the location on...

    I had a phantom zone

    I deleted the location on the Honeywell Server and added it back again and all was well.
    (I read this somewhere on one of the threads)
  25. Replies
    13
    Views
    3,007

    For what it's worth my original system was s-plan...

    For what it's worth my original system was s-plan DHW + CH with zone valve for each driving boiler.

    A couple of years ago I added a 2 zone UFH in an extension

    The UFH controller (not H/well)...