    Maybe I said it wrong then, the plumber wired...

    Maybe I said it wrong then, the plumber wired this up in one of those Honeywell junction box things.

    also when you said you BDR needs to be configured as Central heating and Hotwater, there is no...
  2. Replies
    14
    Views
    1,031

    I managed to get everything working, so for the...

    I managed to get everything working, so for the sake of others reading this, this is how I got it all working.


    1 x BDR connected as Boiler Control (Basically this should be connected to the main...
  3. Replies
    14
    Views
    1,031

    You can only use the strap on with vented...

    You can only use the strap on with vented cylinder. You can use the immersion sensor on a unvented cylinder, however if you take out the immersion element and put the sensor there, you wont have a...
  4. Replies
    14
    Views
    1,031

    Mine is the same in terms of the immersion heater...

    Mine is the same in terms of the immersion heater and the thermostat/aquastat. Since my one is a unvented cylinder I cannot use the strapon sensor and have to use the immersion sensor, the question...
  5. Replies
    14
    Views
    1,031

    Hi G4RHL, How did you fit it, I mean the...

    Hi G4RHL,

    How did you fit it, I mean the thermostat that is fitted to the cylinder is for overheating protection (from my understanding) I have to remove this and out the immersion sensor in...
  6. Replies
    14
    Views
    1,031

    So I was going to avoid using the hot water kit,...

    So I was going to avoid using the hot water kit, as I am not 100% sure what to do with the immersion sensor. Maybe get it added later when I can find a official evohome installer locally.
  7. Replies
    14
    Views
    1,031

    Hi @gordonb3, thank you for replying. Maybe I...

    Hi @gordonb3, thank you for replying.

    Maybe I should clarify, this is a brand new install of everything, my house was fully gutted and renovated. So the boiler and cylinder are brand new and have...
  8. Replies
    14
    Views
    1,031

    Evohome new install

    Hi,

    I just getting to the point where I can finally install my evohome after ordering it 2 months ago (building delays)

    So I have bought the following

    5 x HR92 TRV (controlling 5 rads, each...