  1. Wow, so it's now been 2 years since the last...

    Wow, so it's now been 2 years since the last firmware and no new Evohome replacement products too. What's up Honeywell.
  2. Replies
    7
    Views
    382

    Also remember that you will see the Heat Demand...

    Also remember that you will see the Heat Demand as requested off the boiler, not whether the boiler flame is actually on or not. Another way to determine if the Boiler has a Heat Demand or not is to...
  3. Replies
    15
    Views
    2,234

    I would keep the hybrid system in forever, you...

    I would keep the hybrid system in forever, you are unlikely to gain payback in changing over. Also IMHO UFH zones don't benefit as much from smartening. They don't react fast enough. A properly timed...
  4. Replies
    15
    Views
    2,234

    Is the UFH genuinely zones or just 8 outputs on a...

    Is the UFH genuinely zones or just 8 outputs on a manifold? A lot of people confuse the two. For a proper UFH zone, the pipework under the floor needs to just be under the single zone and you need to...
  5. Replies
    15
    Views
    2,234

    What is the timer controlling, that Evohome isnt?...

    What is the timer controlling, that Evohome isnt?
    It also depends if your boiler needs a 230V Live feed to fire or uses volt free contacts.
    You could just terminate the timer output and the...
  6. Isnt this the same as what we have seen...

    Isnt this the same as what we have seen previously at https://tccna.honeywell.com/WebApi/Help/LogIn
  7. All your stuff will work fine with Evohome. It's...

    All your stuff will work fine with Evohome. It's the only reason I have Evohome. I too made the journey from CM Zone to Hometronic to Evohome. Each time only the controller changed.
  8. You should really try and get a new circuit flow...

    You should really try and get a new circuit flow and return for the UFH circuit. That way the UFH can demand it's own heating separate from the radiator circuit. Is the UFH area really 3 separate...
  9. So you think that the OT Bridge has intelligence...

    So you think that the OT Bridge has intelligence built in to determine that a normal 10% Heat Demand from a zone is different from a Fail Safe 10% demand. Because as I mentioned and as can be seen...
  10. I too have the old TRVs in a box in the garage. I...

    I too have the old TRVs in a box in the garage. I trust them more than Evohome when I need to pull a radiator off the wall.
  11. The 128C is via the API (honeywell server). But...

    The 128C is via the API (honeywell server). But the ~21C is measured by a local HGI80 which shows that the zone valve was still publishing its accurate temperature but for some reason the controller...
  12. OT produced a heat demand during a comm failure...was that the fail safe?

    Woke up in the middle of the night to hear the boiler running, which was odd because the heating system has been Turned Off for while now. We have solar so even the HW is taken care of.
    What I...
  13. You could reconfigure the wired temperature input...

    You could reconfigure the wired temperature input to something else. Any way, the OT gateway can also run in stand alone mode. See http://otgw.tclcode.com/standalone.html#operation
  14. And that even has an input for an outside...

    And that even has an input for an outside temperature sensor
  15. On the HR80 too, I turn the geared wheel anti...

    On the HR80 too, I turn the geared wheel anti clockwise completely, then screw the base to the TRV (clockwise :-) and then turn the geared wheel clockwise till it touches the pin. Then I put the body...
  16. Replies
    17
    Views
    3,209

    In fact on eBay, all Center thermostats seem to...

    In fact on eBay, all Center thermostats seem to be listed with the Honeywell name in the title.
  17. Replies
    29
    Views
    2,943

    I would only get the HCC80 if ever there was a...

    I would only get the HCC80 if ever there was a need to split a single manifold into multiple zones.
  18. Replies
    2
    Views
    2,190

    Smart homes can be quite rigid

    Hear me out.

    My girls decided that their room was smaller than the Guest room so spent the half term relocating. The hard work was actually the easiest.

    What we didn't account for was moving...
  19. Replies
    7
    Views
    1,313

    Nest was in the news recently for exactly the...

    Nest was in the news recently for exactly the same reason. Their cloud service went down and people woke up to cold houses.
  20. Replies
    29
    Views
    2,943

    if the entire manifold is serving one heating...

    if the entire manifold is serving one heating zone, then electric actuators are completely unnecessary. They are only needed if individual runs are serving different rooms, which can be shut off from...
  21. Replies
    29
    Views
    2,943

    Most manifolds won't come with electric ...

    Most manifolds won't come with electric actuators. So it gets simpler. You just wire the BDR91 to open the zone valve feeding the manifold, that in turn switches on the UFH pump. The T87RF becomes...
  22. Replies
    6
    Views
    1,283

    Yes that will work, but that adds another link to...

    Yes that will work, but that adds another link to the chain. You need to then send the Max Flow temperature OT command to the Viessmann.
  23. Replies
    6
    Views
    1,283

    Viessmann with Honeywell OT will make your boiler...

    Viessmann with Honeywell OT will make your boiler reach for the lofty highs of 85+C. I don't think you want that. Go back to using a BDR91 as your boiler controller.
  24. Do you have an indication to know what the...

    Do you have an indication to know what the current heat output is? I was only able to derive this once I was monitoring the eBUS.
  25. In my case, my boiler was specced too large. My...

    In my case, my boiler was specced too large. My Alpha2 pump and the 22mm heating loop are not man enough to take the heat away from the boiler fast enough. The boiler was originally meant to do a lot...