Search:

Type: Posts; User: bruce_miranda

Page 1 of 20 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    16
    Views
    619

    Sorry, I should have been clearer how is your...

    Sorry, I should have been clearer how is your Domoticz getting the Evohome data. Seems to me, you don't have an RF interface that is feeding the Evohome data into Domoticz. You need something like...
  2. Replies
    16
    Views
    619

    What interface are you using to receive the RF...

    What interface are you using to receive the RF signals?
  3. Replies
    16
    Views
    619

    What version of Domoticz are you running? See...

    What version of Domoticz are you running?

    See a screenshot of my Devices list.1859
  4. Replies
    16
    Views
    619

    Have you actually selected the "Fault Logbook"...

    Have you actually selected the "Fault Logbook" sensor to be visible in your Devices list. Sounds like you may not have done that. You need to find the device called Fault Log and make sure it has a...
  5. Replies
    16
    Views
    619

    Click the Notifications button on the Fault Log...

    Click the Notifications button on the Fault Log card found in the Utility sensor page.
  6. I used that too, and I got a real noddy reply. I...

    I used that too, and I got a real noddy reply. I guess they have to assume I am a novice. But the reply comes from a "no-reply" email address, so I have no way to send them more information on the...
  7. How do I raise a case with Resideo/Honeywell

    I think I am fairly certain that I have uncovered a bug with the latest firmware version and need to open a case with Resideo / Honeywell. Having never needed to before, how does one do that?
    ...
  8. Replies
    2
    Views
    179

    The round thermostat T87RF also can use OT and...

    The round thermostat T87RF also can use OT and control the boiler directly as a single room stat.
  9. OK this is definitely a bug, there is absolutely...

    OK this is definitely a bug, there is absolutely nothing in the logs that shows me anything that is changing the Mixing Valve parameters and yet after a while the Actuator Run Time parameter is set...
  10. Even the defaults will change to 1sec after a...

    Even the defaults will change to 1sec after a while.
  11. With the new firmware if I try and change the...

    With the new firmware if I try and change the device type then it loses the binding too. Also you needed to change the device type so that a Heat/Boiler Demand could be created. That is happening...
  12. HM80 Actuator Run Time parameter getting reset

    I'm at a complete loss. I installed a new HM80 mixing valve to control my UFH. I set the Actuator Run Time to 90seconds (which is the default) but something is resetting this parameter in the...
  13. Replies
    69
    Views
    11,502

    This is definitely a bug. The actuator run time...

    This is definitely a bug. The actuator run time is getting over written by "something" and it goes back to 1 sec from the default value.
  14. Replies
    69
    Views
    11,502

    @kevinsmart do you have a HM80 on a controller...

    @kevinsmart do you have a HM80 on a controller with the latest firmware? I have a strange issue where the actuator run time parameter keeps getting reset to 1sec. When I go in to change the setting,...
  15. Replies
    9
    Views
    663

    Electric UFH is an absolute waste of money. It...

    Electric UFH is an absolute waste of money. It shouldn't actually be used for anything other than taking the chill off the tiles in a small bathroom. Never as the main source of heat even in those...
  16. Replies
    9
    Views
    663

    I too finally had to turn the heating on to come...

    I too finally had to turn the heating on to come tomorrow morning for the first time. I'll be watching my UFH and the new HM80 that I installed to control it. Let's see how that goes.
  17. Replies
    6
    Views
    454

    Having Zone Valves in place for main circuits...

    Having Zone Valves in place for main circuits Rads, UFH and HW makes a lot of sense. Even if you latch them open or make them open its still useful to keep them. It then doesn't tie you into Evohome....
  18. If you buy just the motor, not the motor head,...

    If you buy just the motor, not the motor head, you just have 2 wires and twist locks to deal with. You don't have to work out how the motor head has been wired inside the central heating's wiring...
  19. Replies
    6
    Views
    454

    Might still be cheaper to use two BDR91s rather...

    Might still be cheaper to use two BDR91s rather than the Evohome UFH controller for just two zones. You anyway need remote sensors in every zone. But rather than the UFH controller operating the...
  20. Replies
    6
    Views
    454

    Is your extension or the UFH area actually be...

    Is your extension or the UFH area actually be divided into zones that can be shut off from one and other? Or will the entire manifold be serving an open plan area?
  21. What's your HW differential and Overrun set to?

    What's your HW differential and Overrun set to?
  22. Yes its mad when you think how much they sell...

    Yes its mad when you think how much they sell just the spare motor for. How many people are actually changing just the motor? I guess it's a little less work because you don't have to open the main...
  23. Even with the new firmware and while Heating is...

    Even with the new firmware and while Heating is off.?
  24. Replies
    69
    Views
    11,502

    My UFH heating pump is the Adaptive ramp up...

    My UFH heating pump is the Adaptive ramp up version, and the TPI from the BDR91 was making for quite an inefficient system. The pump was almost constantly ramping up, having been abruptly shut down...
  25. Heating Off, the new firmware and TRVs sticking

    I was watching a video on TRV repairs and it seemed to suggest that when the Heating system is switched off for the season all the manual TRVs should be rotated to the open position. This is to stop...