  1. Replies
    5
    Views
    96

    I was never happy about how Den lights witches...

    I was never happy about how Den lights witches were wired. They used Earth as Neutral.

    Other manufacturers *could* do that, but they don't. For good reason.
  2. Replies
    5
    Views
    96

    They had good WAF (wife acceptance factor). Or...

    They had good WAF (wife acceptance factor).

    Or husband acceptance factor for one regular forum poster.
  3. That would only be true if you had HR92s on all...

    That would only be true if you had HR92s on all of your rads (and an ABV).

    Without them, if you did as you've described, you'd have those rads coming on every time your hot water tank needed a...
  4. Replies
    5
    Views
    96

    Den Automation has gone titsup

    According to The Register (who are usually right about these things), Den Automation has gone to the wall.

    It's a shame - the products had a lot going for them. But I'm not surprised. Wearing my...
  5. There's an option sensor that you can connect to...

    There's an option sensor that you can connect to the DHW incoming (I use it as I have a pre-heat tank). Perhaps it's that?

    Difficult to know because Intergas are a bit crap at exposing these...
  6. That's what wireshark is for! The bigger...

    That's what wireshark is for!

    The bigger problem will be certificates. Assuming this stuff is properly secure. Which might not be a good assumption!
  7. Replies
    2
    Views
    239

    Very interesting. That kit is REALLY useful...

    Very interesting.

    That kit is REALLY useful if you have damp issues in your home. Also good for landlords to fit in rentals.

    Doesn't look like all of the products support this. Can't see...
  8. Wired directly to the boiler (instead of using...

    Wired directly to the boiler (instead of using feeds via the zone valves). And configured as boiler control on the controller. Normally with S Plan there's no boiler control (lots of people...
  9. That's why I mentioned traditional wiring! ...

    That's why I mentioned traditional wiring!

    having the extra BDR91 makes a lot of sense. And also protects you from broken microswitches in the zone valves, which seems to be a regular thing.

    P.
  10. Don’t forget that a boiler won’t fire if the...

    Don’t forget that a boiler won’t fire if the water flowing through it is already up to temperature.

    That always used to get me when I had an old iron boiler and a BDR91. There was power to the...
  11. Yup. The wiFi is just for external comms back to...

    Yup. The wiFi is just for external comms back to Resideo.

    P.
  12. Try moving the controller to a different place in...

    Try moving the controller to a different place in the house - perhaps a bit closer to the boiler relay.

    Sounds like something is broadcasting on 868MHz at the same time every day. Neighbour's baby...
  13. You only get those options if you have direct...

    You only get those options if you have direct boiler control.

    If you have an S or Y plan system wired in the 'traditional' manner (i.e. with the boiler being controlled by the microswitches in the...
  14. Replies
    9
    Views
    444

    I'm not sure how this can be lost comms. The...

    I'm not sure how this can be lost comms. The controller itself shows all zones at 0% but (last night) boiler demand of 11%. If it was lost comms HR92->controller then the zones wouldn't all show 0%,...
  15. If those batteries have been in for three years...

    If those batteries have been in for three years they are probably due for a change anyway.
  16. Check the battery in the hot water thermostat. ...

    Check the battery in the hot water thermostat.

    We've seen cases reported here before where that seems to cause knock-on problems with other zones / relays / etc.
  17. Replies
    9
    Views
    325

    Bear in mind that Evohome is no longer Honeywell....

    Bear in mind that Evohome is no longer Honeywell.

    Resideo was spun off as a separate company.

    That will probably affect customer service. I'm not sure in which direction, but hopefully a...
  18. Looks American - talks about furnaces and...

    Looks American - talks about furnaces and cooling. I suspect this is for one of the North American products rather than Evohome, but it would be nice if I'm wrong!
  19. Replies
    9
    Views
    444

    That's different to the example I've seen, where...

    That's different to the example I've seen, where all the zones are zero percent but the controller still shows a boiler demand.

    In your example the controller doesn't turn the boiler on and off....
  20. Replies
    210
    Views
    67,040

    Can you take your family back and get a refund or...

    Can you take your family back and get a refund or exchange?
  21. Replies
    9
    Views
    444

    I've seen that - all zones reporting 0% but the...

    I've seen that - all zones reporting 0% but the boiler demand with a higher percentage. It can sometimes take a minute or so for the controller to realise it should be sending 0% to the boiler. Maybe...
  22. Replies
    356
    Views
    33,796

    What it would achieve is that Evohome and your...

    What it would achieve is that Evohome and your phone would be talking to the Residio servers via different networks. So if you Evohome hasn't got a connection but your phone (via mobile data) is OK...
  23. Replies
    356
    Views
    33,796

    Next time turn off WiFi on your phone and recheck...

    Next time turn off WiFi on your phone and recheck with the app using mobile data.
  24. Replies
    356
    Views
    33,796

    If it was their end wouldn’t everyone here get...

    If it was their end wouldn’t everyone here get the same? I didn’t.

    If your phone was connected to the same WiFi as your controller then the app not connecting just proves that there's a failure...
  25. Replies
    1
    Views
    735

    If the boiler / heating loop is already up to...

    If the boiler / heating loop is already up to temperature it won't fire - it'll just keep circulating the water until the temperature drops. Could that be it?