  1. While you're there Andy, any idea when 19.33 is...

    While you're there Andy, any idea when 19.33 is going to go into general release and the Beta testing period will be over ?

    We've been beta testing these two beta versions since April now, I think...
  2. Single room zone vs multiroom zone is all about...

    Single room zone vs multiroom zone is all about how many temperature sensors there are in a zone and where they are.

    1) Single-room zone - there is only one active temperature sensor for the zone...
  3. Sorry I don't really understand your question.

    Sorry I don't really understand your question.
  4. When you bind devices to a zone the first one you...

    When you bind devices to a zone the first one you add will be the sensor (unless you choose the Evotouch as the sensor) and the rest will only be actuators.

    Unfortunately there is nothing you can...
  5. Are you sure the device is connected to...

    Are you sure the device is connected to WiFi/Internet properly, and showing the Internet icon at the top left ?

    If not, the smart features disappear from the settings menus.
  6. Hang on - is it true that you can't enable load...

    Hang on - is it true that you can't enable load scaling if you don't have an explicit boiler (appliance) control relay ?

    I haven't seen this mentioned before and since the heating relay also does...
  7. Replies
    2
    Views
    115

    That's a very good question which I don't think...

    That's a very good question which I don't think anyone has asked before or has a definite answer to.

    However based on what I know about how the system communicates I would say that optimal start -...
  8. Replies
    8
    Views
    1,039

    So I've just received the email notification from...

    So I've just received the email notification from loop today.

    The "legacy" version of loop is being switched off on the 19th of December and while they'll send out one of their new electricity...
  9. Replies
    20
    Views
    634

    Looks like the same controller I bought in 2015...

    Looks like the same controller I bought in 2015...
  10. Replies
    20
    Views
    634

    The ATF600 actually came out in June 2015 with...

    The ATF600 actually came out in June 2015 with the WiFi controller, I bought my WiFi controller in late 2015 and used an ATF600 wall mount kit. (It even says it came out on June 2015 on the...
  11. Replies
    19
    Views
    629

    The downsides to multi-room zones are: 1) You...

    The downsides to multi-room zones are:

    1) You can't use a remote sensor like a DTS92E, only the built in sensor in the HR92's. (If you add a remote sensor to the zone it will just provide a...
  12. The controller still uses heat demand with a...

    The controller still uses heat demand with a BDR91 - it controls the percentage of time that the relay is on in each (by default) 10 minute cycle.

    So yeah, it's "on/off", but the proportions of on...
  13. From what I've seen, zones that struggle to heat...

    From what I've seen, zones that struggle to heat up can end up with their heat demand not scaled down nearly as much as zones which easily heat up or tend to overshoot - I think that's part of the...
  14. Replies
    19
    Views
    629

    I see you are graphing the measured temperature...

    I see you are graphing the measured temperature from both HR92's in the zone - is the zone configured as a single room zone or a multi-room zone ? If the former, which one is configured as the sensor...
  15. You can pair up to 4 controllers to each BDR91. ...

    You can pair up to 4 controllers to each BDR91.

    So in the case of a two Evotouch system you would have only one controlling the hot water relay (if you had hot water control) and then both...
  16. As far as I know Evohome is an EU/UK product...

    As far as I know Evohome is an EU/UK product only.

    Six per day per zone. I do find myself hitting that limit if I try to get "clever" with my schedules.

    People have been asking for this for...
  17. Try switching Advanced Load Scaling to "Partial"...

    Try switching Advanced Load Scaling to "Partial" mode. This reduces how much the heat demand is scaled down. I found the "Normal" mode scaled the load down too much on my system and I saw similar...
  18. Already possible, I've always had the idle screen...

    Already possible, I've always had the idle screen disabled on mine.

    Go to Settings -> Device Settings -> Idle Screen, and set it to the right most option - Off. :)
  19. Replies
    2
    Views
    163

    To be honest, if you already have a regular hot...

    To be honest, if you already have a regular hot water timer controlling the hot water zone valve (and via that the boiler) and it does what you want I would probably just stick with it unless you...
  20. Replies
    19
    Views
    629

    When you retrieve the current set points from the...

    When you retrieve the current set points from the Web API (either V1 or V2 API) you can't directly tell if a set point is due to optimal start acting or not - it just reflects the set points...
  21. Sorry, I had it confused with the Custom mode...

    Sorry, I had it confused with the Custom mode where you can choose the zones that are affected. You're right - Eco mode applies to all zones.
  22. Ok. That looks the same as what I see when I get...

    Ok. That looks the same as what I see when I get a sudden cold snap - it undershoots the set point by maybe 0.5C, remains steady at that value for quite a while and then gradually creeps up to the...
  23. If they were to remove the 0.5C bias towards the...

    If they were to remove the 0.5C bias towards the set point from the temperature displayed on the controller (and phone app) which they could certainly do, all the other devices like HR92 and DTS92E...
  24. 19C seems pretty cold to me... ? Do you use...

    19C seems pretty cold to me... ?

    Do you use the HR92 as the temperature sensor for the zone or do you use a remote wall sensor like a DTS92E or Y87RF ?

    If you're setting the set point lower...
  25. Glad to hear its working well for you as it does...

    Glad to hear its working well for you as it does for me.

    On the room that undershoots do you mean it just doesn't hit its target temperature in time but does reach it later ? (In which case...