  1. That sounds like the Open Window setting getting...

    That sounds like the Open Window setting getting stuck as a Permanent Override.
  2. Even with OT? Because that is where OT scores...

    Even with OT? Because that is where OT scores over a normal ON/OFF control.
  3. Also, am I to use Constant Pressure or Constant...

    Also, am I to use Constant Pressure or Constant Speed in an UFH installation?
  4. My UFH uses a GRUNDFOS UPM3 AUTO L and just...

    My UFH uses a GRUNDFOS UPM3 AUTO L and just reading the manual it appears that for almost 5 years I've not realised that my installer has forgotten to change the default setting of the pump from...
  5. Keeping the Zone Valve BDR91 open longer for UFH

    I have my UFH configured as a Zone Valve and I use a BDR91 as my actuator. The BDR91 opens a motorised zone valve, which in turn starts the UFH pump.
    I don't have a Boiler Relay because I use...
  6. Replies
    39
    Views
    1,222

    Both Dan and I couldn't work out how to integrate...

    Both Dan and I couldn't work out how to integrate the schedule features of the HGI-80 with the rigid code base structure of Domoticz. So we just abandoned the idea. Javascript wasn't either of our...
  7. Replies
    15
    Views
    626

    Isn't the pump considered a replaceable part of...

    Isn't the pump considered a replaceable part of the heating system and thus must be accessible. Installing it under the floorboards has got to be just asking for trouble.
  8. I used to use the feature (bug) a lot during the...

    I used to use the feature (bug) a lot during the Summer when the Heating was set to OFF to dry the towels. Spin the knob on the HR valve and the boiler would fire up, even though heating was set to...
  9. @ally153 If we are making a list of bugs that are...

    @ally153 If we are making a list of bugs that are not fixed in .33 here is one.
    When radiator valves are used on all radiators, Evohome's normal advice is not to use a zone valve on the CH circuit....
  10. So lets say Cold Boost was in play and the Wifi...

    So lets say Cold Boost was in play and the Wifi drops. Does the set point drop as though Cold Boost was disabled. Or will the Cold Boost set point still remain. I understand that weather compensation...
  11. Your choices are : An internet weather feed for...

    Your choices are : An internet weather feed for your entire city/town. A local sensor on your house that might not have a great location.
  12. Replies
    14
    Views
    688

    This is why I coded the Fault Log notifications...

    This is why I coded the Fault Log notifications in Domoticz. Then the user can decide what they want to do with it. Not having notifications (push or emails) for errors that only show up on the...
  13. You had one (in fact I did too!) and it worked on...

    You had one (in fact I did too!) and it worked on the V2 controllers. It was just stupidly expensive. Bring that back at a decent price, I am sure the functionality is already in your code base. Like...
  14. So is all weather compensation abandoned if the...

    So is all weather compensation abandoned if the Internet weather feed cannot be retrieved.
  15. Just one question. What happens when Evohome...

    Just one question. What happens when Evohome cannot connect to WiFi? One of THE best features of Evohome is the independence from the Internet. We are now blurring those lines. I still believe a...
  16. Also does Evohome use the RealFeel for it's...

    Also does Evohome use the RealFeel for it's weather compensation or the actual temperature?
  17. Could we please have some information about what...

    Could we please have some information about what service is used to determine external temperature against which all the weather compensation works? It's now clear that it's not using a local sensor,...
  18. Also can we please please please get per zone...

    Also can we please please please get per zone Optimisation back again.
  19. Wasn't the current BETA meant to be able to read...

    Wasn't the current BETA meant to be able to read the OT outside temperature? Or are we saying that was intended but never implemented and still isn't? If that is the case what outside temperature is...
  20. Replies
    1
    Views
    785

    It all depends on how many valves you have that...

    It all depends on how many valves you have that need opening. If I just had these parts, I would use the BDR91 as Boiler control, in parallel to whatever you have currently firing the boiler to deal...
  21. These days, unfortunately, I find myself asking...

    These days, unfortunately, I find myself asking this a lot...."Are you guys still in business"?.
  22. Replies
    9
    Views
    684

    And check that the outside temperature is as...

    And check that the outside temperature is as displayed. It's clear that is cannot be used for proper weather compensation.
  23. For once I am happy I have OT and dodged this...

    For once I am happy I have OT and dodged this Load Scaling bullet. It would have driven me nuts because I work from home and most days have only a single radiator on in the study, which happens to...
  24. Replies
    9
    Views
    684

    See what the icon looks like in my first zone.

    See what the icon looks like in my first zone.
  25. First of all, what makes you think that your...

    First of all, what makes you think that your current setup isn't modulating. People often confuse modulation and maximum flow temperatures. Unless you have an eBus monitor or the evohome OT gateway,...
Results 1 to 25 of 500