  1. Replies
    2
    Views
    1,602

    Replacement hot water sensor

    Does anyone know if it's possible to source a replacement hot water sensor for the Evohome system? Mine has started dropping out for an hour or two at a time according to the fault log on the...
  2. Replies
    4
    Views
    2,830

    I disconnected and isolated the immersion heater...

    I disconnected and isolated the immersion heater probe and inserted the temperature sensor down the hole instead. The hot water relay is then wired in series with the existing dual stat set to its...
  3. Replies
    5
    Views
    2,928

    Delete the system devices from the controller...

    Delete the system devices from the controller (boiler relay or hot water setup), clear the BDR91(s) by pushing and holding the button until the light blinks slowly, then repair.
  4. If you have a close neighbour might be worth...

    If you have a close neighbour might be worth asking if they've recently installed anything new - garage door openers / powerline networking etc.
  5. Replies
    12
    Views
    5,360

    You really need a flow meter installed after the...

    You really need a flow meter installed after the bypass valve so you can ensure that sufficient water is going through the boiler to satisfy the minimum requirement. "Slackening the valve" a bit is...
  6. You can adjust the offset IIRC - my controller...

    You can adjust the offset IIRC - my controller sits in the hall and controls it to a noticeably lower temperature than the living room even though both are set the same.
  7. Replies
    98
    Views
    57,197

    Jurassic Park is my all time favourite.

    Jurassic Park is my all time favourite.
  8. Replies
    31
    Views
    12,949

    The newer firmware.

    The newer firmware.
  9. Replies
    31
    Views
    12,949

    It's in the current firmware on the WiFi model.

    It's in the current firmware on the WiFi model.
  10. Try moving the controller closer to the router. ...

    Try moving the controller closer to the router. It took several attempts for mine to talk to my Sky router and in the end the two had to be almost touching. Once connected it works fine, however.
  11. Replies
    31
    Views
    12,949

    Swap the radiator heads around. Some seem to have...

    Swap the radiator heads around. Some seem to have better range than others.
  12. To be honest, I just squirted a bit of thermal...

    To be honest, I just squirted a bit of thermal paste into the hole and stuffed the sensor in, wedging it as you did with a bit of sheathing. Works fine.
  13. Replies
    138
    Views
    76,427

    Thanks Rameses - emailed yesterday and had a...

    Thanks Rameses - emailed yesterday and had a reply within 10 minutes telling me the firmware was on its way. :-)

    That's the sort of customer service to be proud of.
  14. Replies
    10
    Views
    5,309

    I've set my lounge up as a multi-room zone...

    I've set my lounge up as a multi-room zone because it's long and thin with a radiator at each end. This way tends to avoid cold spots.
  15. Some quick actions will take a time / date finish...

    Some quick actions will take a time / date finish time and some just a date. It's a restriction in the controller software, unfortunately - it doesn't matter if you pass a finish time in the API...
  16. Replies
    11
    Views
    4,076

    Hi emmeesse - although quick actions are enabled...

    Hi emmeesse - although quick actions are enabled pretty much instantly (in the WP app the icon should pick up a green tick), relaying the new setpoint to each zone can take a few minute. The Evohome...
  17. Replies
    5
    Views
    2,193

    I think you'd need another BDR91 and one of...

    I think you'd need another BDR91 and one of these:
    ...
  18. Replies
    5
    Views
    3,872

    To live (link the second L and A). I've also...

    To live (link the second L and A).

    I've also done the above, works fine.
  19. Replies
    14
    Views
    8,367

    You can use whatever colours you like provided...

    You can use whatever colours you like provided you label them, but that's how I'd do it.
  20. Replies
    81
    Views
    45,605

    You could also try swapping TRVs around - some...

    You could also try swapping TRVs around - some might be better transmitters than others.
  21. Replies
    14
    Views
    8,367

    Is it this one? ...

    Is it this one?

    http://s299.photobucket.com/user/electricianforum/media/Central-Heating-System-Wiring/HoneywellJunctionBoxWiringCentre420.png.html

    I think it'll give you a headache and suggest...
  22. Replies
    57
    Views
    28,908

    Rod, the TF87 doesn't show a flame icon when it's...

    Rod, the TF87 doesn't show a flame icon when it's pairing to the Evohome system.
  23. Replies
    7
    Views
    5,252

    Hi Mike, If your plumber is trained to work...

    Hi Mike,

    If your plumber is trained to work with unvented cylinders he'll know that the existing stats must be maintained. However, he could drill a small hole in the steel casing, remove a bit...
  24. Replies
    7
    Views
    5,252

    You shouldn't interfere with the overheat stats...

    You shouldn't interfere with the overheat stats on an unvented cylinder because of regulations, but it's not particularly dangerous. Think about it - your boiler will simply cycle on and off on it's...
  25. Temp sensing on the HR92 is spot on in my...

    Temp sensing on the HR92 is spot on in my experience.
Results 1 to 25 of 84