  1. Replies
    108
    Views
    12,735

    If you have HW scheduled to come on that...

    If you have HW scheduled to come on that frequently you might never see the notorious comms failure error. Go for it. I have Solar panels, so it's not unusual for my HW to not come on for several...
  2. Replies
    108
    Views
    12,735

    It all depends how you have your HW schedule set....

    It all depends how you have your HW schedule set. If the HW temperature is constantly changing it causes the sensor to send our messages more frequently, which works fine for the Controller.
  3. Replies
    108
    Views
    12,735

    Believe it or not the bug is in the Controller...

    Believe it or not the bug is in the Controller and not the sensor. It's caused by the Controller missing the infrequent sensor message when the temp of the water is not changing rapidly.
    People...
  4. Replies
    108
    Views
    12,735

    Simon has learnt to live with the quirkiness of...

    Simon has learnt to live with the quirkiness of the system. He hasn't thrown his system away. We all use it quite actively. And even though it's not perfect, it's still probably the best smart...
  5. Replies
    108
    Views
    12,735

    We have investigated this issue to death. The HW...

    We have investigated this issue to death. The HW sensor will transmit very rarely when it's not in an active heating cycle and thus the HW temperature is not changing frequently enough. Nothing you...
  6. Replies
    108
    Views
    12,735

    It's a firmware bug, not a hardware bug. Get it,...

    It's a firmware bug, not a hardware bug. Get it, and learn to live the issues. It tends to work fine during an active heating cycle anyway.
  7. Replies
    4
    Views
    331

    I thought only the BDR91T can deal with the...

    I thought only the BDR91T can deal with the cooling reverse demand and the BDR91 can only deal with heat demand.
  8. As for the relays, this is how it works in...

    As for the relays, this is how it works in Domoticz. By default the relays in the system will get named and have the same ID as Controller. However these devices will report the Heat Demand. While...
  9. In a zone with a H92 and a T87RF, Domoticz will...

    In a zone with a H92 and a T87RF, Domoticz will produce 2 or 3 devices, depending on if you pressed the "All Sensors" option on the Hardware at any point.
    My default you should have.
    1. Sub Type...
  10. You are suggesting what I have tried and found...

    You are suggesting what I have tried and found impossible to achieve with Evohome. However I have another problem in that my boiler has landed up getting oversized due to changes in our heating...
  11. Same here. Setting it to highest fixed speed was...

    Same here. Setting it to highest fixed speed was my only solution.
  12. Now you will appreciate why I didn't spend too...

    Now you will appreciate why I didn't spend too much time translating the Device ID to names, because a single Device ID could actually have two names in Domoticz.

    Here is how:
    Let's say you have...
  13. The do sell coloured sleeves for a reason :-)

    The do sell coloured sleeves for a reason :-)
  14. Yes the SSM shows up as ACM0 due to the way the...

    Yes the SSM shows up as ACM0 due to the way the Atmel drivers work. The MCU used in the SSM no longer needs a separate Serial to USB interface, which generally announces itself as a USB0.
  15. I was just going to say, looks like someone just...

    I was just going to say, looks like someone just used a 3 core flex. Ignore all normal colour coding
  16. I wrote this bit of Domoticz code and took the...

    I wrote this bit of Domoticz code and took the easiest (read laziest) route possible to get the fault log extracted and into Domoticz.
    The hex translation to a device name is actually quite simple....
  17. Domoticz definitely does a better job at getting...

    Domoticz definitely does a better job at getting a new user up and running. I've done a lot of work to keep Domoticz up to date, but I wish it was easier to maintain. Each time I make a change, I...
  18. Chris, It's important that people realise what...

    Chris, It's important that people realise what they have bought. The SSM simply provides a gateway to capture, process and report all the Evohome radio traffic, in a text format. So first off, on...
  19. Replies
    7
    Views
    752

    The only stacked Quick Action that I have found...

    The only stacked Quick Action that I have found is Eco With Day Off, and that too it is hidden from the Evohome UI. I had to write a special Domoticz one to expose it to users. Invaluable during...
  20. Replies
    3
    Views
    329

    If the boiler can drive the pump, then surely...

    If the boiler can drive the pump, then surely there must be a setting related to it. Unless the boiler is clever enough to detect that it's not got a pump connected and so hides that setting
  21. The issue with this is that your Cylinder with...

    The issue with this is that your Cylinder with starve the radiators from getting enough of heated water from the boiler.
  22. Replies
    3
    Views
    329

    It could easily be that the pump over run time...

    It could easily be that the pump over run time has been set to 0, at the boiler
  23. So much to do, so little time. But just you wait,...

    So much to do, so little time. But just you wait, come Oct, everyone will be tinkering with this.
  24. Feel free to start a new thread about Evohome and...

    Feel free to start a new thread about Evohome and Domoticz, either here or on the Domoticz Evohome subforum.
  25. Yes there is, you pull the schedules via the...

    Yes there is, you pull the schedules via the radio messages.
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4