Search:

Type: Posts; User: mtmcgavock

Page 1 of 19 1 2 3 4

Search: Search took 0.01 seconds.

  1. Is it a Greenstar CDI? If it is youíll need some...

    Is it a Greenstar CDI? If it is youíll need some new electrodes fitted by a gas safe engineer and probably a service
  2. Replies
    2
    Views
    267

    Evohome & Somfy

    Anyone managed to connect Evohome to Somfy Tahoma?
  3. Notifications when a zone isn't heating correctly...

    Notifications when a zone isn't heating correctly after say 1/2 hour or so.
  4. Sounds like the boiler isn't working....at a wild...

    Sounds like the boiler isn't working....at a wild guess if it's a condensing boiler and your somewhere chilly is it possible the condensate will have frozen up?

    Should be a feature on EvoHome. to...
  5. I actually found Cold Weather Boost quite useful...

    I actually found Cold Weather Boost quite useful yesterday - I've set it to a differential of 18oc. When temps here plummeted here yesterday to below 0oc i've got a couple of rooms that feel cooler....
  6. Use a custom Quick Action schedule and not apply...

    Use a custom Quick Action schedule and not apply it to the zones you don't want to. For instance I use that feature for Summer, setting all zones to 15oc bar my bathrooms then I can override my Towel...
  7. Replies
    8
    Views
    1,543

    As the HR92 is acting as an Actuator for the zone.

    As the HR92 is acting as an Actuator for the zone.
  8. Can confirm that the new update is on the latest...

    Can confirm that the new update is on the latest controllers being shipped out. Fitted a system today and it has the new update :)
  9. Replies
    6
    Views
    526

    Sorry yes, I meant 5v. TBH i've never really paid...

    Sorry yes, I meant 5v. TBH i've never really paid much attention to the voltage of the controller :rolleyes:
  10. Replies
    6
    Views
    526

    I usually locate the transformer remotely, and...

    I usually locate the transformer remotely, and just use the twin and earth to supply 12v to the backplate. Usually stick the transformer in the airing cupboard or something with the wiring centre.
  11. That's great, just wanted to know when my...

    That's great, just wanted to know when my customers my be getting it! I'd seen a newly packaged EvoHome stating it had the new features but a number of customers hadn't got the update so that makes...
  12. Replies
    8
    Views
    1,543

    Fit two HR92s :rolleyes:

    Fit two HR92s :rolleyes:
  13. When does the Beta go to Public Release, or has...

    When does the Beta go to Public Release, or has it already?
  14. The vented section is the store only, the HW is...

    The vented section is the store only, the HW is supplied by mains pressure that runs through a coil.

    Only want round it would be to fit a new vented cylinder like I assume you have now.
  15. Isnít going to be any different for a thermal...

    Isnít going to be any different for a thermal store? Itís still mains pressure for the HW...

    Theyíre just a bad idea IMO, ripped so many out over the years. Iíd have a combi before a thermal store.
  16. You'd be better with an Unvented HW cylinder than...

    You'd be better with an Unvented HW cylinder than a thermal store, especially if you've only got one heat source. You'd have to heat the store to a high temperature, for longer periods than you do...
  17. It'll have a job as it's not a condensing boiler...

    It'll have a job as it's not a condensing boiler ;)

    In my tests I certainly found that it uses less gas. It's hard to monitor due to weather conditions, but I try to log them along with my...
  18. This isn't quite true. After taking numerous Gas...

    This isn't quite true. After taking numerous Gas readings over the course of 4 years i've concluded it's actually cheaper (Usage is less) to heat our home all Day whilst we're at work than it is...
  19. Our usage is very minimal in the morning (We...

    Our usage is very minimal in the morning (We shower in the evenings), hand washing and that's about it. Our cylinder heats to 56oc, and looses 8oc overnight - so it usually sits at around 48oc in the...
  20. Mines on 3pm till 11pm at night. Depends on your...

    Mines on 3pm till 11pm at night. Depends on your usage I suppose....
  21. Depends what cylinder you have, is it a old...

    Depends what cylinder you have, is it a old fashioned Copper cylinder or a new Stainless Steel Unvented cylinder?
  22. Replies
    8
    Views
    1,030

    How long has the Evohome system been installed?...

    How long has the Evohome system been installed? As said in another thread it takes up to 3/4 weeks to fully learn your system.
  23. It'll pretty much stay the same as your current...

    It'll pretty much stay the same as your current system however - You'll have no pump externally, and the boiler will require a permanent Live (If your current one doesn't already!). The BDR91s stay...
  24. Replies
    13
    Views
    1,777

    Have you adjusted the internal sensor offset if...

    Have you adjusted the internal sensor offset if you're using the EvoHome Panel as a sensor? You have to adjust it by about -1.5oc to get a true temperature reading.
  25. Replies
    13
    Views
    1,777

    The system takes up to 3 weeks to learn. Leave it...

    The system takes up to 3 weeks to learn. Leave it alone and let it learn your system.

    Have you got HR92s or just set up as a Single Zone?

    My system is to the degree - no issues here.
Results 1 to 25 of 456