  1. Sounds good, looking forward to testing it. :)

    Sounds good, looking forward to testing it. :)
  2. I would try rebooting all the devices in the zone...

    I would try rebooting all the devices in the zone (HR92 and any wall sensors) by removing the batteries and reinserting them.

    HR92's have been known to generate spurious heat demand before (or...
  3. Did you check the heat demands in the system...

    Did you check the heat demands in the system installer menu in the evotouch ? That should tell you which zone demanded heat.

    What are your night time set points and what temperatures were the...
  4. Ah, good to know that you're alive and well and...

    Ah, good to know that you're alive and well and the project is continuing. :) Looking forward to whatever the something is.
  5. Lets hope we're not all stuck on this buggy beta...

    Lets hope we're not all stuck on this buggy beta release indefinitely. :D I had kind of expected the beta period to be over a month or more ago...

    Given how infrequent the stable releases are for...
  6. Replies
    10
    Views
    929

    Maybe, but replacing batteries every 3 months for...

    Maybe, but replacing batteries every 3 months for 5 1/2 years can't be cheap either. And for me the annoyance factor would be too much...
  7. Replies
    10
    Views
    929

    5.5 years of suffering poor battery life and you...

    5.5 years of suffering poor battery life and you still haven't replaced it yet for one that isn't faulty ? :)
  8. Mine has been on partial for a few weeks now too....

    Mine has been on partial for a few weeks now too. It certainly helps a lot, (vs full) however I'm still sometimes unable to get heat from a single zone (usually the bathroom) when other zones have no...
  9. Same problem here with my bathroom radiator and I...

    Same problem here with my bathroom radiator and I raised this issue with Andy further up thread...

    I had to drop down load scaling from full to partial because I was completely unable to get the...
  10. Replies
    9
    Views
    425

    The low battery icon within zone squares on the...

    The low battery icon within zone squares on the home screen was there in previous non-beta firmware.

    Strange that you're not seeing a message in the fault log though - I have always had a low...
  11. To be fair, the old way where turning up an HR92...

    To be fair, the old way where turning up an HR92 manually in heating off mode still worked (but didn't show anything on the controller) was always a bug or oversight.

    A lot of people were unhappy...
  12. How did you use the App to revert your firmware ?...

    How did you use the App to revert your firmware ? I haven't seen or heard any way to do that...
  13. Replies
    4
    Views
    235

    FYI, The YT87RF and DTS92E are both available...

    FYI,

    The YT87RF and DTS92E are both available with or without a bundled BDR91, so you don't need to build up a large supply of unwanted BDR91's.... :cool:

    The cost saving of the thermostat only...
  14. Yes a much discussed "known bug", check out the...

    Yes a much discussed "known bug", check out the beta firmware thread for more discussion about it.

    On the plus side Andy the Minion has already said quite some time ago that the problem is known...
  15. Same here - with the hot weather we've been using...

    Same here - with the hot weather we've been using a Custom action configured to 5C (discussed in another thread) to keep the heating off but still overrideable for towel drying etc, so whenever any...
  16. I wonder if Andy the Minion has any news for us...

    I wonder if Andy the Minion has any news for us on when the next firmware release might be out ? Whether a release candidate of a public release or a further beta release ?

    Looking back in this...
  17. Replies
    8
    Views
    443

    I concur - if your flow temperature is shared...

    I concur - if your flow temperature is shared between radiators and hot water reheat as it is in my system (no flow temperature "boost" for hot water reheat) then the flow temperature should be a...
  18. I think you might be confused - locking an HR92...

    I think you might be confused - locking an HR92 (so that it says blocked when you turn the dial or press the button) is something you have always had to do from the zone configuration in the...
  19. Replies
    3
    Views
    313

    It shows the first HR92 which was bound to the...

    It shows the first HR92 which was bound to the zone, which is also the one that would be used as the only sensor if you switched the zone back to single room zone. If you're not sure which one it is...
  20. Adaptive load scaling does not do what you...

    Adaptive load scaling does not do what you apparently think it does. It does not cause additional "stop/start" cycles in any significant way.

    TPI (Time proportional integral) has been an integral...
  21. Replies
    2
    Views
    238

    If you're referrig to the "OFF" setting directly...

    If you're referrig to the "OFF" setting directly on an HR92 when turning the dial (not just setting it to 5C) then yes this is the expected behaviour.

    OFF tells the HR92 to completely ignore the...
  22. Ok, good to hear. Yes I did notice a slow...

    Ok, good to hear.

    Yes I did notice a slow integral action but it still wasn't enough to allow the boiler to actually come on. Don't get me wrong, I understand what the algorithm is trying to do, I...
  23. Replies
    19
    Views
    1,563

    The problem with the Eco quick action is it can't...

    The problem with the Eco quick action is it can't be used in conjunction with the Day Off quick action. And during the lockdown our system is on permanent Day Off mode when it isn't on heating off...
  24. The replacement valve arrived yesterday so I got...

    The replacement valve arrived yesterday so I got the head swapped over and wired back in. Two things I noticed since then, both expected:

    1) No more rooms going over temperature during hot water...
  25. Hi Andy, Can you confirm whether the load...

    Hi Andy,

    Can you confirm whether the load scaling bug I reported earlier in the thread (with load scaling preventing frost protection working) is a known bug or has been addressed (or at least...