  1. Good idea, G4RHL re custom schedule being date...

    Good idea, G4RHL re custom schedule being date governed. I get close to doing this by keeping the three (or four with Xmas) seasonal schedules in an excel spreadsheet (will provide for anyone wanting...
  2. Yep, that's what I understood and so reacted same...

    Yep, that's what I understood and so reacted same as you - DIY the setting as needed.



    This is the part I am unsure about. Last weekend when the weather picked up, there was strong sunlight in...
  3. Great pieces of information, Robbietobbie, on...

    Great pieces of information, Robbietobbie, on some of your experience with the new firmware. The cold weather boost is the one I'm likely to use as, during winter months, I normally up the temps from...
  4. Replies
    20
    Views
    1,805

    Appreciate the very useful information.

    Appreciate the very useful information.
  5. Replies
    20
    Views
    1,805

    The above comments are pretty much the reason I...

    The above comments are pretty much the reason I asked users (18th March) for recommendations running the new firmware - because the new functions surely improve on optimisation performance.
    But what...
  6. Latest firmware 02.00.19.33 - Suggestions for migrating from non-optimised control

    Have run Evohome over 5 years on a non-optimised basis i.e. time and temps scheduled according to expected weather patterns and have updated my system to the latest firmware but reluctant to make...
  7. Well at least I got the automatic acknowledgement...

    Well at least I got the automatic acknowledgement email so I shall live in hope!
  8. After being told by ally53 that responsibility...

    After being told by ally53 that responsibility for roll out is with the "connected team" which will initially be released "to a small percentage of the Evo population", I emailed the Resideo...
  9. I have now received a PM response from ally53 in...

    I have now received a PM response from ally53 in which he confirmed the following:
    " firmware is in approval stages for general release. Once approved, this will be a staged process which will be...
  10. Agree with all your comments. It's a pity...

    Agree with all your comments. It's a pity Honeywell/Resideo haven't been as smart as they could have been in maintaining/updating/improving the Evohome system.
    I think if it wasn't for the shared...
  11. I sent a PM to ally53 a few days back asking him...

    I sent a PM to ally53 a few days back asking him exactly that question but not heard anything back yet. [The post by ally53 14th December refers]
    I asked 27th January if any forumites had received...
  12. It usually takes up to an hour for some more...

    It usually takes up to an hour for some more distant radiator TRVs to re-connect (handshake) with the controller. Some zones quicker than others but very rare for any zone to be still trying to...
  13. My two penneth's worth is that if it wasn't for...

    My two penneth's worth is that if it wasn't for the likes of DBMandrake and other contributors who freely offer their unstinting detailed advice and knowledge - Honeywell/Resideo would be in deep pig...
  14. Since ally53 advised back in mid-December that...

    Since ally53 advised back in mid-December that the new release would be rolled out gradually . . . . . has anyone actually received the updated firmware WITHOUT having requested it via the trial...
  15. Replies
    31
    Views
    3,828

    Try this link and also within the thread...

    Try this link and also within the thread Anniesboy original link
    https://www.automatedhome.co.uk/vbulletin/showthread.php?6255-Why-is-my-evohome-controller-beeping&highlight=controller+batteries
  16. Replies
    31
    Views
    3,841

    All points well said, CT1. I think there's lots...

    All points well said, CT1. I think there's lots of Evohome users on your wavelength here.
  17. HR92 shows hourly battery failure on controller

    One of my HR92s has started showing a battery low warning screen. When I check the faults page, there is often one battery warning approximately every hour (a minute or so different each time) yet...
  18. Replies
    28
    Views
    6,432

    I have a WB Greenstar 40CDI boiler, similar to...

    I have a WB Greenstar 40CDI boiler, similar to yours, and used to have continual cycling issues. Eventually I arranged for WB to install a later version main PCB, which reputedly (per internet...
  19. Replies
    28
    Views
    6,432

    Other thoughts - is the pump under-sized for the...

    Other thoughts - is the pump under-sized for the system or equally is the boiler under-sized, i.e. number of radiators @ various BTU ratings matching boiler output.
    If the boiler was under-sized and...
  20. Replies
    28
    Views
    6,432

    I run my condensing Worcester boiler at 70C flow...

    I run my condensing Worcester boiler at 70C flow temp (sometimes 72C when it's colder outside), so you could increase yours a tad.

    Also, is the sitting room one of the furthest rooms from the...
  21. Further to DBMandrake's detailed graph and...

    Further to DBMandrake's detailed graph and explanation, I did re-check the HR92 valve position which when showing 46%, the corresponding demand at the controller was 11% - perfectly matching the...
  22. Thanks DBMandrake for a comprehensive response,...

    Thanks DBMandrake for a comprehensive response, as always.

    I will check out your various suggestions tomorrow when can experiment some more.

    I did have the Kitchen/Conservatory originally set...
  23. Apologies for late response due to weekend...

    Apologies for late response due to weekend arrangements.

    Just checked again this morning with TRV showing 23C. Controller shows demand of 9%. HR92 shows valve position is 0. Kept checking for...
  24. Yes, the HR92 is set to display measured...

    Yes, the HR92 is set to display measured temperature. These temps show during the daytime, often when my wife is at work - and I don't do any cooking at all in the day.

    The kitchen is in an open...
  25. Strange regular 2C over setpoint temp reading on Kitchen HR92

    I keep getting a regular 23C temperature read on the kitchen HR92 when the setpoint temp is 21C. Wondering if the reading is being skewed because the radiator is a 2 metre tall vertical type?

    Any...