Search:

Type: Posts; User: Mid112

Search: Search took 0.00 seconds.

  1. Replies
    2
    Views
    219

    I would recommend finding out if the issues are...

    I would recommend finding out if the issues are caused by evo or maybe you have boiler/system issue.

    Resetting evo and rebinding wouldnt do harm, guides can be found on the internet. Evo support...
  2. Replies
    13
    Views
    513

    I dont think it works that way. They all work a...

    I dont think it works that way. They all work a bit independently to what i have found out.
  3. Replies
    13
    Views
    513

    Hi In the options you can change settings from...

    Hi

    In the options you can change settings from multi to single zone. Not sure what one are you on.
    I have had 2 rads and evo in livingroom and decided to split it two two separate zone ie...
  4. Thanks this would explain a bit. But i think...

    Thanks this would explain a bit.

    But i think parameter 0 does not work on xclusive at all as it never skips a cycle but responds with min flow.

    Does this work on older intergas boilers?
  5. If I set the boiler to allow Opentherm to go as...

    If I set the boiler to allow Opentherm to go as low as 25C then set up parameter "Ignore OT demand if the setpoint for the flow temperature is below minimum" (30C)"
    The boiler comes on with 25/26C...
  6. Another way to look at OpenTherm low load low/off...

    Another way to look at OpenTherm low load low/off control is that Evohome has no idea what the lowest flow setpoint is. It can read the Max CH water setpoint (which is often wrong e.g. Intergas...
  7. I rebinded and reset everything twice with...

    I rebinded and reset everything twice with evohome support.
    Swapped Opentherm for a newer one - same issue.

    Just to say - this issue happens only when a demand on evehome is only a couple of %...
  8. The boiler responds fine and modulates between...

    The boiler responds fine and modulates between 40-70c depending on actual usage.

    57 is set either to 0 or 1 - it doesnt make much difference which on is actually set

    Is definetely not on on/off.
  9. I have Intergas xclusive 30 - it can modulate by...

    I have Intergas xclusive 30 - it can modulate by design to 25C by design If I remeber correctly with 30C set by default.

    So what has been happening was that when there was very low heat demand ie...
  10. I have had a huge issues with this 1min on 1off,...

    I have had a huge issues with this 1min on 1off, i think there is another unresolved thread about it.

    Im on the beta fw and i think evo works a bit better with latest fw however i dont think its...
  11. Replies
    0
    Views
    337

    Evohome and intergas - opentherm

    Hello

    Im still trying to get the best setting for intergas xclusive 30 which was installed couple of months ago.

    We have evohome with 4 hr92s and opentherm

    The problem is mainly with one...
  12. Replies
    12
    Views
    2,118

    Spot on The boiler was full of air since i...

    Spot on

    The boiler was full of air since i blead it, the water is circulating correctly
  13. Replies
    12
    Views
    2,118

    Ive done some research today. The temp of a room...

    Ive done some research today. The temp of a room was 20C, using a dial on hr92 i inceased the temp to 25C

    Boiler started to cycle as above. The flow Ch pipe was boiling hot, hr92 open on 100,...
  14. Replies
    12
    Views
    2,118

    Thanks for your input. The problem is that...

    Thanks for your input.

    The problem is that radiator doest have time to heat up as entire pricess doest take longer than a minute.

    I will try changing the parameter on the boiler and check if...