  1. Got the Hr92 fitted on the towel rad a couple of...

    Got the Hr92 fitted on the towel rad a couple of days ago and it’s working perfectly well,we can now dry our towels without running anything else apart from the plinth heater.Decided to leave the...
  2. That's great,thank you.Will get this done over...

    That's great,thank you.Will get this done over the weekend.The boiler does have it's own abv built in as well.
  3. Thanks for the detailed reply,very informative...

    Thanks for the detailed reply,very informative and understood.My boiler has a two speed pump that runs on speed one at a certain kw setting and on speed two over a certain kw setting,can’t remember...
  4. Hr92 on all radiators bar plinth heater with opentherm

    Just wanting some advise,my system comprises of a Vaillant 831 ecotec plus combi boiler,vr33 opentherm bridge controlled by evohome with honeywell opentherm bridge.My radiators all have the hr92...
  5. Replies
    19
    Views
    2,640

    Two break downs in 10years is exceptional,as in...

    Two break downs in 10years is exceptional,as in that it's nothing and to be perfectly honest I would have expected more issues than I've had,the Alpha I had before it was an absolute nightmare of a...
  6. Replies
    19
    Views
    2,640

    Makes for some very interesting reading,I too...

    Makes for some very interesting reading,I too have a Vaillant 831 Ecotec plus combi.This was installed nearly ten years ago after the Alpha combi that a friend of mine recommended that I had...
  7. Bit of an update,boiler set to 19kw,flow 60...

    Bit of an update,boiler set to 19kw,flow 60 degrees on the boiler.Seems to be working well,getting longish burn times with return temps at the moment in the low 50s,the most important thing is...
  8. Hi,I don't unfortunately and my knowledge is...

    Hi,I don't unfortunately and my knowledge is quite limited as far as that goes.What would I need to do in order to see the required information from the ebus.
  9. Just checked and the 831 does indeed share the...

    Just checked and the 831 does indeed share the same pcb board as the ecotec pro 24 and 28.Set the boiler to 19kw,will monitor what happens,fingers crossed it modulates lower.
  10. Hmm,that's given me an idea.I was told that the...

    Hmm,that's given me an idea.I was told that the 831 was a slightly higher spec boiler than the ecotec pro 24/28,the 24 model modulates down to 6.7 from 19kw so it might be worth me trying that,may...
  11. Yes,your right I will leave it set to max as it...

    Yes,your right I will leave it set to max as it is modulating so should sort it's self out.Once the boiler is over 15kw the pump speed is on 2,the fastest speed,below that it on 1,the slower...
  12. Yes,I quickly found that out and set the max in...

    Yes,I quickly found that out and set the max in the boiler to 65 degrees as when set at 75 degrees which is my boilers default max,the radiators got far too hot and I have two children,could be very...
  13. Installed the vr33 and the open therm bridge,set...

    Installed the vr33 and the open therm bridge,set boiler to max kw and flow temp,not sure that's correct but the boiler seems to be doing what it should.Not sure if I should turn the boiler stat...
  14. Ordered a Vr33 open therm bridge today from...

    Ordered a Vr33 open therm bridge today from Holland,just need the Honeywell open therm bridge and then I can get this installed,will post updates once done.
  15. Think auto is max then it modulates down to...

    Think auto is max then it modulates down to what's needed,mines an older boiler and you have to manually set the output then it modulates down from there.You get a good flow temp from your system and...
  16. Hi,the figures are 8.7-24 kW.Do you have yours...

    Hi,the figures are 8.7-24 kW.Do you have yours set on max,mine is set to 20 KW at the moment,1926 house,cavity wall
    downstairs with solid brick upstairs.The cavity wall has insulation and 300mm of...
  17. Vaillant 831 Eco Tec Plus combi with open therm

    Hi,wanting to know if it's worth having open therm on the Vaillant 831 Eco Tec plus combi,I know the vr33 will fit and work with my boiler.This being run by a Honeywell evohome and zoned using the...