    Iím optimistic, :-) Resideo did mention some...

    Iím optimistic, :-) Resideo did mention some changes for heat pump support to BDR91 etc. Iíll soon find out.
  2. Replies
    14
    Views
    411

    https://theevohomeshop.co.uk/honeywell-home-connec...

    https://theevohomeshop.co.uk/honeywell-home-connected-thermostats/11-honeywell-evohome-connected-thermostat-pack-atp921r3100-5025121073547.html

    Mentions the 2020 controller.
  3. Replies
    14
    Views
    411

    Ah thanks, there is a new 2020 controller though,...

    Ah thanks, there is a new 2020 controller though, Iíll let you know what the differences are.
  4. Replies
    14
    Views
    411

    New home, mammoth Evohome install

    Just placed a huge order with the EvoHome Shop for my new house, after getting to grips with the existing set up (Danfoss controls).

    Comprises of:
    16 x DTS92E Room Thermostats (I chose these as...
  5. Replies
    12
    Views
    2,795

    Does anyone have multiple EvoHome controllers...

    Does anyone have multiple EvoHome controllers working with OpenTherm?

    Iíve just moved into a new house. It has 17 thermostats (!) controlling UFH via 4 manifolds, a few towel radiators and DHW. ...
  6. Replies
    8
    Views
    676

    Typically this happens when the controller is not...

    Typically this happens when the controller is not docked properly and its battery is discharging and running low.
  7. Replies
    6
    Views
    643

    Iíve broken a couple before. You can buy...

    Iíve broken a couple before. You can buy replacements.
    ...
  8. The way I do this is with an IFTTT button widget...

    The way I do this is with an IFTTT button widget on my phone.

    You can create an Applet like 'If Button press Then Set a zone temperature Living-Dining 21 Celsius 1 Hours'.

    It's slightly more...
  9. I think the recommendation according to the...

    I think the recommendation according to the installation manual, when you have HR92s, is to have a wirelessly connected BDR91 or R8810 boiler control, not a wired connection.

    You can still use...
  10. Replies
    19
    Views
    1,883

    The 🔁 icon indicates those zones are permanently...

    The 🔁 icon indicates those zones are permanently set to the specified temperature, so wonít follow their schedule, and either not heat if set to a low temperature, or heat and maintain a higher...
  11. http://elektronetshop.shopgate.com/item/3738303933...

    http://elektronetshop.shopgate.com/item/373830393332
  12. https://www.bolasystems.com/controller-for-3-point...

    https://www.bolasystems.com/controller-for-3-point-mixing-valve-with-honeywell-hm80-propulsion
  13. Thatís where I got mine but I had to wait a...

    Thatís where I got mine but I had to wait a while, as production was moving to a new factory. It was worth it though, but the EvoHome shop donít have much experience of it, so couldnít provide much...
  14. Iím sorry but I canít seem to view your diagram. ...

    Iím sorry but I canít seem to view your diagram.

    Why use Heatmiser at all? If you donít want to use HCC80 you can instead control each zoneís actuator by a BDR91. Then use a T87RF, DTS92...
  15. Hi Saaj, Do you find that HCC80s in combination...

    Hi Saaj,
    Do you find that HCC80s in combination with OpenTherm works well?

    The reason I ask is that I am moving house next month and expect to be installing this setup, probably 4 HCC80s, 1 per...
  16. What version of firmware is running? I think you...

    What version of firmware is running? I think you may need to request an update.
    ...
  17. Hold down the Settings menu for 5 seconds, then...

    Hold down the Settings menu for 5 seconds, then press System Summary.
  18. I think it is a mistake in the Xclusive's manual....

    I think it is a mistake in the Xclusive's manual. If you look in other Intergas manuals, for instance my boiler, you'll see the following descriptions.

    Parameter E: Min. Supply temperature during...
  19. That is the correct behaviour. You've set the...

    That is the correct behaviour. You've set the minimum temperature for OT demand to 25C, so the minimum seen should be 25C and not any temperature less than this.

    I'll try to find out by...
  20. Another way to look at OpenTherm low load low/off...

    Another way to look at OpenTherm low load low/off control is that Evohome has no idea what the lowest flow setpoint is. It can read the Max CH water setpoint (which is often wrong e.g. Intergas...
  21. I never said it was a problem, I think you...

    I never said it was a problem, I think you doubted that this mode of operation occurred, hence my explanation.
  22. It's not new, it's described as "When an...

    It's not new, it's described as "When an appliance is no longer able to modulate lower the control switches from modulating control to low/off control.". The T6 thermostats have a more sophisticated...
  23. Not quite. You will see this with OpenTherm and...

    Not quite. You will see this with OpenTherm and no heating valve when the low load algorithm comes into play. (I seem to keep repeating myself on this).

    The algorithm sends a >10C flow...
  24. Yes, it appears to be, every 10mins or so. A...

    Yes, it appears to be, every 10mins or so. A plot of the flow temperature request might show short 10C (off) requests.
  25. Hi Dan, With EvoHome and HR92 on all radiators...

    Hi Dan,

    With EvoHome and HR92 on all radiators you really should keep the CH valve open. I have a Normally Open valve fitted which closes when DHW is being heated.

    I guess what is happening...